Chapter 2 moves from universal transformer physics to converter-specific excitation. The same core and winding set can behave very differently depending on whether the converter applies a single-ended forward pulse, alternating push-pull excitation, a half-bridge or full-bridge square wave, a flyback energy-storage interval, or a resonant waveform. The transformer must therefore be designed from the actual winding voltage, current, timing, reset, and commutation conditions—not from topology name alone.
← Previous Chapter
In This Chapter — Click to Expand
Table of Contents
CHAPTER SCOPE
Compare the Magnetic Excitation, Then Go Deeper in the Topology Guides
This chapter compares the transformer-facing behavior of the major isolated power-converter families. It does not replace the dedicated SolidMagnetics Flyback and Resonant Converter Transformer guides.
The key questions are: What voltage appears across the winding? For how long? What resets the core? Does flux swing unipolarly or bipolarly? What asymmetry can accumulate? Those answers establish the magnetic design inputs.
1. Topology Defines the Transformer’s Applied Waveform
A transformer responds to the instantaneous voltage applied to each winding and the resulting current and magnetic field. Different topologies create different voltage amplitudes, polarities, duty limits, zero-voltage intervals, reset intervals, dead times, and current waveforms.
SOLIDMAG ENGINEERING INSIGHT
Start with the Winding Waveform
Before selecting a core or primary-turn count, draw the actual primary-winding voltage over one complete switching cycle. Mark every positive interval, negative interval, zero-voltage interval, reset interval, and dead time.

Figure 2-1. Isolated converter topologies create different transformer excitation waveforms. The applied primary voltage, polarity sequence, duty interval, reset mechanism, and zero-voltage intervals determine how the core is used.
2. Steady-State Operation Requires Volt-Second Balance
For a transformer that returns to the same magnetic operating point every steady-state switching cycle, the net flux change must be zero.
Equivalently, the primary winding must have approximately zero net volt-seconds over the complete reset cycle.
Positive and negative voltage intervals need not have equal magnitudes; their signed volt-second areas must cancel.
3. Single-Ended and Bipolar Excitation Use the Core Differently
Single-ended excitation moves flux in one direction during the active interval and relies on a separate reset or demagnetization interval. Bipolar excitation alternates polarity and can reset the core through the following interval when the two sides are balanced.
| Excitation family | Typical examples | Magnetic implication |
|---|---|---|
| Single-ended | Forward; flyback energy-storage interval | Explicit reset or demagnetization behavior is required |
| Alternating / bipolar | Push-pull; half-bridge; full-bridge | Positive and negative excitation can self-reset when balanced |
| Resonant / shaped | LLC; CLLLC; resonant families | Waveform and current depend on resonant network, frequency and load |

Figure 2-2. Primary-winding voltage and core-flux behavior for representative isolated topologies. The voltage integral—not topology name—determines the flux trajectory and reset requirement.
4. Flyback Is a Coupled-Inductor Energy-Storage Case
Flyback is a special case because the magnetic component intentionally stores energy in magnetizing inductance during the primary ON interval and delivers that energy during the OFF interval.
For the topology-specific treatment, use the Ultimate Guide to Flyback Transformer Design.
5. Single-Switch Forward Transfers Energy During the ON Interval
In a single-switch forward converter, energy transfers through the transformer while the primary switch is ON. A first-pass positive flux excursion is:
The transformer is not intended to store the main cycle energy, but magnetizing current still rises during ON time and the core must be reset before the next cycle.
6. A Forward Transformer Must Be Reset Every Cycle
Forward reset applies opposite volt-seconds so the next switching cycle starts from a controlled magnetic state.
For a common idealized reset-winding arrangement, a first-order maximum duty ratio is:
Equal primary and reset turns give the familiar approximately 50% duty limit; practical designs require timing and tolerance margin.
ENGINEERING CAUTION
Reset Is a Hard Magnetic Timing Requirement
The controller’s possible duty cycle must not exceed what the transformer reset circuit can safely support.

Figure 2-3. Forward-converter reset methods. Different reset circuits produce different reverse primary-voltage amplitudes and therefore different allowable reset times, duty-cycle limits, and flux trajectories.
7. Two-Switch and Active-Clamp Forward Change the Reset Mechanism
Two-switch forward returns magnetizing energy through the switch/diode clamp network, while active-clamp forward uses an active switch and clamp capacitor to shape the reset interval. These circuits share the forward energy-transfer concept but do not impose the same off-state primary waveform.
8. Push-Pull Alternates the Core Through Two Primary Halves
Push-pull uses a center-tapped primary with the two primary halves energized alternately. Balanced alternating excitation reverses core flux without a separate reset winding.
Any systematic mismatch between the two primary halves, switch timing, voltage drops, or drive conditions can shift the average flux operating point.
9. Half-Bridge Applies Approximately Half the DC Bus to the Primary
A voltage-fed half bridge ideally applies approximately half the DC bus to the primary with alternating polarity.
For a rectangular interval, the first-order flux excursion is:
The lower primary voltage permits fewer turns than a full bridge for the same core area, pulse duration, and flux excursion.
10. Full-Bridge Applies the Full DC Bus with Reversing Polarity
A full bridge can apply approximately the entire DC bus to the primary with either polarity.
For the same pulse duration:
For the same core and allowed flux excursion, the full bridge needs roughly twice the primary turns of a half bridge operated from the same DC bus.
11. Phase-Shifted Full Bridge Changes Effective Pulse Width and Commutation
Phase-shifted full bridge controls power through phase displacement between bridge legs. The transformer can see active power-transfer intervals, freewheel or zero-voltage intervals, commutation current, and leakage-assisted switching transitions. Flux calculations use the actual differential primary voltage while winding-current design includes circulating and commutation current.
EARLY ENGINEERING ACCESS
Get Your First Custom Magnetic Design for $49
Need a custom inductor, flyback transformer, or currently supported LLC/resonant transformer design for a real project? SolidMagnetics Early Engineering Access gives you a lower-cost way to evaluate the platform while it continues to expand.
STANDARD SINGLE DESIGN PRICE: $249 • EARLY ACCESS PRICE: $49
Use coupon code EARLYACCESS. Your supported design package can include:
- Candidate magnetic design output and recommended design direction
- SolidWorks Reference CAD and STEP export where supported
- Engineering drawings, BOM, winding, and design data where supported
- A practical starting point for component matching, simulation, prototyping, or further development
Offer details: Limited to the first 10 qualified paid projects. One discounted project per customer. Expires February 12, 2027, or when all 10 uses are claimed, whichever comes first.
SolidMagnetics-generated designs are engineering starting points intended to accelerate development. Final component selection, manufacturability, tolerances, winding construction, insulation, creepage and clearance, thermal performance, regulatory requirements, and production suitability must be verified for the intended application.
12. Resonant Converters Create Frequency-Dependent Transformer Waveforms
Resonant converters intentionally shape current and voltage with reactive elements. In LLC operation, magnetizing inductance can participate in resonant behavior and transformer leakage can provide part or all of the series resonant inductance.
Use the Ultimate Guide to Resonant Converter Transformer Design for the detailed resonant operating solution.
13. Waveform Shape Determines Flux Excursion
The most reliable flux calculation is the winding-voltage integral over the actual interval. A useful proportional relationship is:
The proportional form is useful for intuition, but final design should use the actual waveform integral whenever excitation is asymmetric, clamped, resonant, or otherwise nonrectangular.
14. Duty Cycle, Dead Time, and Reset Time Are Magnetic Constraints
Duty cycle sets pulse duration. Dead time introduces intervals in which device capacitance, body diodes, magnetizing current, resonant current, or leakage energy may determine primary voltage. Reset time must be sufficient to cancel the active interval’s volt-seconds.
15. Small Volt-Second Errors Can Create Flux Walking
A repetitive positive/negative volt-second error can move the flux operating point farther in one direction each cycle.
Timing mismatch, unequal bridge midpoint voltages, mismatched push-pull halves, control offsets, and startup transients can all create imbalance.
ENGINEERING CAUTION
Flux Walking Can Turn a Small Electrical Error into a Saturation Event
Small repetitive volt-second imbalance can progressively shift the magnetic operating point until one side of the B-H loop reaches saturation.

Figure 2-4. Flux walking from repetitive volt-second imbalance. Balanced bipolar excitation keeps the flux trajectory centered; systematic asymmetry can shift the operating point toward saturation.
16. Current Imbalance Can Reveal a Flux-Balance Problem
Flux imbalance often appears as asymmetric primary-current peaks, unequal switch current, unequal heating, or a growing magnetizing-current offset. These symptoms are useful diagnostics but should be separated from leakage, load, rectifier, and current-sense asymmetries.
17. Topology Changes Core Utilization and Required Turns
Topology changes the applied primary voltage, flux swing, reset mechanism, copper utilization, switch stress, and effective use of the core. There is no meaningful transformer optimization until the topology and operating waveform are fixed.
18. Turns Ratio Must Be Derived from the Actual Topology
The ideal winding relationship remains:
But the voltage used in the ratio is the actual winding voltage created by the topology. A 400 V DC bus may produce approximately ±200 V across a half-bridge primary and approximately ±400 V across a full-bridge primary.
19. Transformer Voltage Stress and Switch Stress Are Coupled
Topology changes switch blocking voltage, rectifier stress, leakage-energy paths, clamp requirements, common-mode dv/dt, and insulation stress. Transformer and semiconductor design must therefore be closed together.
20. Topology Comparison — What the Transformer Must Accomplish
| Topology | Primary excitation | Core reset | Transformer-specific emphasis |
|---|---|---|---|
| Flyback | Single-ended energy-storage interval | Secondary demagnetization / clamp behavior | Lm, gap, peak current, reflected voltage, leakage energy |
| Single-switch forward | Single-ended power-transfer pulse | Explicit reset winding or clamp/reset network | Reset volt-seconds, duty limit, magnetizing current |
| Two-switch / active-clamp forward | Single-ended power-transfer pulse | Clamp or active-clamp reset | Actual reset voltage and commutation |
| Push-pull | Alternating center-tapped primary halves | Self-reset if balanced | Half-primary matching, flux walking |
| Half-bridge | Alternating approximately ±Vin/2 | Self-reset if balanced | Bus midpoint balance, dead time, circulating current |
| Full-bridge / PSFB | Alternating approximately ±Vin | Self-reset if balanced | Full-bus primary voltage, phase shift, freewheel intervals |
| LLC / resonant | Bridge voltage with resonant current | Alternating plus resonant constraints | Lm, Lr/leakage, gain window, ZVS, capacitance |
21. Worked Comparison — 400 V Bus, Half-Bridge vs Full-Bridge
For a simplified 400 V DC bus comparison, hold core area, pulse duration, and allowable flux excursion constant and ignore switch drops and dead time.
| Case | Ideal primary voltage | Relative turns requirement | Key observation |
|---|---|---|---|
| Half bridge | approximately ±200 V | 1× reference | Half the bus appears across the primary |
| Full bridge | approximately ±400 V | approximately 2× half-bridge turns | Twice the applied voltage requires twice the turns for the same Ae, ton and ΔB |
This comparison demonstrates the magnetic voltage/turns consequence only; overall current, device count, conduction loss, power level, and control strategy also change.
WORKED EXAMPLE TAKEAWAY
Same Bus Voltage Does Not Mean Same Transformer Voltage
A half bridge and full bridge operating from the same DC bus require different transformer turns and flux calculations because they do not apply the same voltage to the primary winding.
22. Recommended Topology-to-Transformer Workflow
- Define input range, output requirements, isolation, switching-frequency range, and control strategy.
- Choose the converter topology and draw the exact primary power-stage connections.
- Derive the primary winding voltage for every switch state, including reset and dead time.
- Integrate positive and negative volt-seconds over the complete magnetic cycle.
- Set initial primary turns and calculate worst-case flux-density excursion.
- Verify reset time and maximum duty or phase-shift limits.
- Check asymmetry mechanisms that could create flux walking.
- Derive secondary winding voltage and turns ratio from the actual topology and rectifier arrangement.
- Calculate peak/RMS winding current, magnetizing current, leakage stress, and commutation current.
- Hand the resulting topology-derived operating window to Chapter 3 as the transformer requirement set.

Figure 2-5. Topology-to-transformer design workflow. Converter switch states are converted into actual winding waveforms, reset constraints, turns and flux targets, current stresses, and the transformer requirement set.
23. Chapter 2 Engineering Checklist
- Topology and bridge configuration are explicitly identified.
- The actual primary winding voltage is derived for every switch state.
- Positive and negative/reset volt-seconds are balanced.
- Worst-case voltage, duty/phase shift, and minimum frequency are included.
- Forward reset method and maximum duty limit are defined where applicable.
- Push-pull primary halves and drive timing are evaluated for symmetry.
- Half-bridge midpoint balance is considered.
- Full-bridge and PSFB freewheel/commutation intervals are represented.
- Flyback energy storage is not modeled as an ordinary forward transformer.
- Resonant waveforms come from the resonant operating solution rather than assumption.
- Primary turns use the actual applied winding voltage and core area.
- Turns ratio uses topology-specific voltage relationships.
- Flux walking and startup/transient asymmetry are checked.
- Leakage-energy and device-voltage stress paths are understood.
- Chapter 3 receives a complete operating window rather than a nominal point.
24. Conclusion — Design from the Applied Waveform, Not the Topology Name
A topology name is shorthand for a set of switch states. Transformer design becomes reliable only when those states are translated into actual winding voltage, current, timing, reset, and commutation waveforms.
Chapter 3 converts those topology-derived waveforms into a formal transformer requirement set covering line/load range, frequency, current, isolation, thermal limits, mechanical envelope, EMI, manufacturing, and validation.
Technical References for This Chapter
For production work, use current controller documentation, semiconductor data, core/material data, and topology-specific application guidance.
- Texas Instruments — Power Topologies training series.
- Texas Instruments SLVAFW4 — Forward Converter.
- Texas Instruments SPRABW0D — Voltage-Fed Full-Bridge Converter.
- Texas Instruments SLUP224 — Power Supply Design Seminar.
- Power Integrations — Forward Converter Reset Sensing.
- Fundamentals of Power Electronics, Erickson and Maksimović, 3rd Edition.
- Transformer and Inductor Design Handbook, McLyman, 4th Edition.
Related SolidMagnetics Resources
Ultimate Guide to Transformer Design
Return to the complete 15-chapter transformer-design roadmap.
Chapter 1 — Transformer Design Fundamentals
Review turns ratio, Faraday’s law, volt-seconds, flux density, magnetizing inductance, and real transformer behavior.
Ultimate Guide to Flyback Transformer Design
Detailed flyback treatment of energy storage, conduction modes, gap design, leakage, loss, safety, and validation.
Ultimate Guide to Resonant Converter Transformer Design
Detailed resonant treatment of Lm, Lr, controlled leakage, gain, soft switching, windings, loss, and validation.
SOLIDMAGNETICS DESIGN TOOLS
Explore Magnetic Design Automation
Use the SolidMagnetics Magnetic Design Automation page as the central directory for available and developing design workflows that connect converter requirements to magnetic calculations, buildable geometry, CAD, manufacturing outputs, and validation.
← Previous Chapter
READY TO APPLY THIS?
Turn Your Requirements Into a Real Magnetic Design
If you are working on a real inductor, flyback transformer, or supported LLC/resonant transformer project, SolidMagnetics can help you move faster from electrical requirements to calculated magnetic geometry and engineering output.
FOUNDING EARLY ENGINEERING ACCESS: $249 → $49
Use coupon code EARLYACCESS for the Single Design package. This offer is intended for engineers who want to evaluate the current SolidMagnetics workflow and provide practical feedback that helps improve the platform.
What the Current Package Can Include
- Requirements and feasibility review
- Candidate design comparison and recommended design
- Electrical, magnetic, loss, and thermal calculations
- SolidWorks Reference CAD and STEP files where supported
- Drawings, BOM, winding, and engineering data where supported
- A basis for comparing custom geometry with commercial core and bobbin options
Early Access Offer Details
- Single Design standard price: $249
- Early Engineering Access price: $49
- Coupon code: EARLYACCESS
- Limited to 10 total qualified paid projects
- One discounted project per customer
- Expires February 12, 2027, or when all 10 uses are claimed
- Brief post-delivery feedback is requested
The standard package provides a Reference CAD representation of the generated design rather than the complete underlying SolidMagnetics parametric automation structure. Fully parametric engineering CAD may be available separately for qualifying advanced or Enterprise projects.
Early Access calculations, CAD, drawings, and related deliverables are intended to accelerate engineering evaluation and prototype development. Final mechanical, electrical, thermal, insulation, regulatory, manufacturing, and production validation remains the responsibility of the customer and their engineering team.