Chapter 12: Core Loss, Copper Loss, Efficiency, and Thermal Design

Chapter 11 fixed the physical winding arrangement and therefore the leakage, capacitance, and high-frequency field environment. Chapter 12 now closes the design thermally by combining ferrite core loss, hot AC copper loss, terminations, fringing and shield losses, thermal resistance, operating duty cycle, and temperature-dependent material behavior across the complete LLC operating window.

This chapter is intentionally iterative. Copper resistance rises as the winding heats. Ferrite loss changes with temperature, frequency, flux density, and waveform. RAC changes with frequency and geometry. The final temperature therefore cannot be calculated once from room-temperature data; loss and temperature must converge together, then be verified on hardware.

In This Chapter — Click to Expand

Table of Contents

DESIGN ASSUMPTION

Chapter 12 Uses Measured or Vendor-Supported Loss Inputs

Core loss is not assigned to a ferrite grade until a material and core are actually selected. The worked example uses a clearly labeled hypothetical vendor-returned loss density to demonstrate the calculation chain.

The worked winding example continues the Chapter 10 illustrative values: 2.8 A RMS primary, 10.8 A RMS secondary, hot 80 °C RDC values, and example RAC/RDC multipliers of 1.6 primary and 1.8 secondary after the Chapter 11 winding stack is chosen.

A one-node 14 K/W thermal resistance is used only for a first-pass educational temperature calculation. Final designs require geometry- and installation-specific thermal correlation.

1. Thermal Closure Is the Final Test of the Electrical Design

An electrically feasible transformer can still fail because its winding hotspot, ferrite temperature, adhesive, bobbin, insulation, sleeving, or solder termination exceeds its allowable temperature. Thermal closure is therefore a feasibility check, not a packaging afterthought.

SOLIDMAG ENGINEERING INSIGHT

Loss Is Not the Final Metric — Temperature Is

Two transformers with the same total watts of loss can have very different hotspot temperatures because the loss is distributed differently and the heat paths are different.

A released design must satisfy both loss and temperature limits.

2. Separate Core, Copper, Termination, and Stray Losses

Track losses by physical source so each mechanism can be improved independently:

Ptr=Pcore+PCu,P+PCu,S+Pterm+PotherP_{tr}=P_{core}+P_{Cu,P}+P_{Cu,S}+P_{term}+P_{other}
PCu,total=PCu,P+PCu,S+PCu,auxP_{Cu,total}=P_{Cu,P}+P_{Cu,S}+P_{Cu,aux}
Pmagnetic=Pcore+Pfringe+PshieldP_{magnetic}=P_{core}+P_{fringe}+P_{shield}
  • Ferrite hysteresis/eddy/core loss.
  • Primary AC copper loss.
  • Secondary AC copper loss.
  • Auxiliary/bias winding loss.
  • Lead, pin, tab, and termination loss.
  • Gap-fringing-induced conductor loss.
  • Electrostatic/magnetic shield loss.
  • Nearby conductive hardware loss where leakage fields are significant.

3. Core Loss Must Use the Selected Material at the Actual f, B, and T

If the selected ferrite vendor provides loss density Pv at the actual operating point, total core loss is:

Pcore=Pv(f,B,T)VeP_{core}=P_v(f,B,T)V_e

For multiple core pieces or deliberately separated magnetic elements:

Pcore,total=∑i=1NcPcore,iP_{core,total}=\sum_{i=1}^{N_c}P_{core,i}

TDK’s current Magnetic Design Tool explicitly represents power loss as a function of temperature, frequency, and flux density and multiplies loss density by effective magnetic volume to obtain core-set loss.

4. Non-Sinusoidal Flux Requires a Waveform-Aware Core-Loss Method

A simple Steinmetz-like expression is often written:

Pv≈ksfαBβP_v\approx k_sf^\alpha B^\beta

But LLC transformer flux is not always a pure sine wave. TDK’s current tool includes a non-sinusoidal core-loss function because waveform shape matters. Use vendor waveform guidance, an appropriate generalized Steinmetz method, or measured loss data when the sinusoidal approximation is not valid.

5. Core Loss Can Shift Strongly with Temperature

Ferrite loss can have a strong and non-monotonic temperature dependence. The loss at 25 °C is not necessarily conservative for operation at 80–120 °C.

Always evaluate Pv at the operating temperature range rather than applying one generic temperature coefficient.

6. Hot Copper Resistance Must Be Recalculated

Copper resistance rises approximately linearly over the normal winding temperature range:

RT=Rref[1+αCu(T−Tref)]R_T=R_{ref}\left[1+\alpha_{Cu}(T-T_{ref})\right]

That temperature correction feeds directly back into winding loss, so the thermal solution must be iterated.

7. RAC/RDC Carries the Skin-and-Proximity Penalty into the Thermal Model

Use the Chapter 10/11 AC-resistance multiplier:

FR=RACRDCF_R=\frac{R_{AC}}{R_{DC}}
RAC=FRRDCR_{AC}=F_RR_{DC}
RAC(T)≈FR(T,f,geometry)RDC(T)R_{AC}(T)\approx F_R(T,f,\mathrm{geometry})R_{DC}(T)

TDK’s current transformer tool allows RAC/RDC from the wire calculation to be carried into power/temperature calculations, explicitly including skin and proximity effects.

8. Harmonic Current Can Be Evaluated Frequency by Frequency

If winding current contains significant harmonics, a frequency-by-frequency loss model is:

PCu,harm=∑hIh2RAC(h)P_{Cu,harm}=\sum_h I_h^2R_{AC}(h)

This is more accurate than multiplying total RMS current by one RAC value when the current spectrum extends far beyond the switching fundamental.

9. Leads and Terminations Can Be Significant on High-Current Secondaries

A termination resistance that looks small can create substantial heat on a high-current secondary:

Pterm=IRMS2RtermP_{term}=I_{RMS}^2R_{term}

Measure or estimate copper-foil tabs, litz solder joints, pins, PCB vias, busbars, and connector transitions where they form part of the transformer assembly.

10. Sum the Complete Transformer Loss Budget

The complete transformer-loss budget is:

Ptr=Pcore+PCu,P+PCu,S+Pterm+PotherP_{tr}=P_{core}+P_{Cu,P}+P_{Cu,S}+P_{term}+P_{other}

Keep the loss breakdown intact through optimization. A lower total loss does not tell you whether the remaining hotspot is in the core, inner primary layer, foil edge, pin, or gap-fringing region.

Transformer loss breakdown showing core loss, primary and secondary AC copper loss, termination loss, gap-fringing loss, shield loss, nearby-metal loss, and their contribution to total thermal load.

Figure 12-1. Transformer loss breakdown showing core loss, primary and secondary AC copper loss, terminations, gap-fringing loss, shield loss, and nearby-metal loss.

11. Transformer Efficiency Is Useful but Temperature Is the Real Constraint

Transformer-only efficiency can be written:

ηtr=PoPo+Ptr\eta_{tr}=\frac{P_o}{P_o+P_{tr}}

Efficiency is useful for system optimization, but the physical transformer is accepted by hotspot temperature, material limits, insulation lifetime, and margin.

12. A One-Node Thermal Resistance Gives the First Temperature Estimate

A first-pass one-node thermal model is:

ΔT=Plossθth\Delta T=P_{loss}\theta_{th}
Thot=Tamb+PlossθthT_{hot}=T_{amb}+P_{loss}\theta_{th}

The effective thermal resistance depends on core size, exposed surface, winding coverage, PCB mounting, airflow, enclosure, potting, and nearby heat sources. TDK’s current tool likewise allows its default free-air thermal resistance to be replaced with an application-specific value.

13. Core and Winding Temperatures Usually Need Separate Thermal Nodes

A more useful reduced-order model separates winding and ferrite nodes:

TCu=Tamb+θCu−CuPCu+θFe−CuPcoreT_{Cu}=T_{amb}+\theta_{Cu-Cu}P_{Cu}+\theta_{Fe-Cu}P_{core}
TFe=Tamb+θCu−FePCu+θFe−FePcoreT_{Fe}=T_{amb}+\theta_{Cu-Fe}P_{Cu}+\theta_{Fe-Fe}P_{core}

For detailed designs, multiple winding layers, bobbin, core halves, PCB, potting, and enclosure can be represented with a thermal-resistance network or CFD/FEA model.

Reduced transformer thermal network showing copper and ferrite heat-generation nodes connected to ambient, PCB, airflow, and each other through thermal resistances.

Figure 12-2. Reduced thermal network with copper and ferrite heat-generation nodes connected to ambient, PCB, and each other.

14. Temperature and Loss Must Be Iterated to Convergence

Temperature changes the loss that creates temperature, so solve iteratively:

T(k+1)=Tamb+θthPloss(T(k))T^{(k+1)}=T_{amb}+\theta_{th}P_{loss}(T^{(k)})

Stop when the temperature solution converges within the desired tolerance:

εT=|T(k+1)−T(k)|\varepsilon_T=|T^{(k+1)}-T^{(k)}|

ENGINEERING CAUTION

A Single Room-Temperature Loss Calculation Is Not Thermal Closure

Hot copper resistance is higher, ferrite loss may move up or down with temperature, and the thermal path can change with potting or airflow.

Iterate until electrical loss and temperature are self-consistent.

15. Define Hotspot Margin Against the Real Material and Insulation Limits

Thot,max≤TlimitT_{hot,max}\le T_{limit}

A normalized temperature-margin metric is:

MT=Tlimit−Thot,maxTlimit−Tamb,max×100%M_T=\frac{T_{limit}-T_{hot,max}}{T_{limit}-T_{amb,max}}\times100\%

Tlimit should reflect the lowest applicable limit among conductor insulation, bobbin, tape, adhesive, ferrite/material behavior, solder/termination, reliability target, and product safety requirements.

16. The Highest-Loss Corner Is Not Always the Highest-Flux Corner

The low-line corner may have the highest B but lower frequency. High line may have lower B but higher frequency. Nominal line may carry the highest sustained power. Core loss is a nonlinear function of all three, so evaluate each actual f/B/T operating point.

17. Low Line, Nominal Line, and High Line Stress Different Loss Mechanisms

Operating CornerLikely Thermal Driver
Low line / boostHigh flux and resonant current; possible high copper + core loss.
Nominal / near resonanceHigh transferred power and sustained duty; often strong total-loss point.
High line / above resonanceHigher frequency, potentially higher switching-related core and AC winding penalties.
Light loadLow average power but possible high frequency / burst-edge behavior.

EARLY ENGINEERING ACCESS

Get Your First Custom Magnetic Design for $49

Need a custom inductor, flyback transformer, or currently supported LLC/resonant transformer design for a real project? SolidMagnetics Early Engineering Access gives you a lower-cost way to evaluate the platform while it continues to expand.

STANDARD SINGLE DESIGN PRICE: $249   •   EARLY ACCESS PRICE: $49

Use coupon code EARLYACCESS. Your supported design package can include:

  • Candidate magnetic design output and recommended design direction
  • SolidWorks Reference CAD and STEP export where supported
  • Engineering drawings, BOM, winding, and design data where supported
  • A practical starting point for component matching, simulation, prototyping, or further development

Offer details: Limited to the first 10 qualified paid projects. One discounted project per customer. Expires February 12, 2027, or when all 10 uses are claimed, whichever comes first.

SolidMagnetics-generated designs are engineering starting points intended to accelerate development. Final component selection, manufacturability, tolerances, winding construction, insulation, creepage and clearance, thermal performance, regulatory requirements, and production suitability must be verified for the intended application.

18. Light Load and Burst Mode Can Still Create Thermal or Acoustic Problems

Light load can reduce average transformer heating while increasing maximum switching frequency. Burst mode creates pulse trains with full-amplitude flux and current separated by idle intervals.

Ploss,avg=∑jDjPloss,jP_{loss,avg}=\sum_j D_jP_{loss,j}

Average temperature may remain low while audible noise, local edge heating, or ZVS loss becomes the actual problem.

19. Startup and Overload Need Transient Thermal Checks

Startup, overload, and protection events can create short periods of high current or unusual frequency. For a short event, integrate the loss energy:

Epulse=∫Ploss(t)dtE_{pulse}=\int P_{loss}(t)\,dt

Compare event duration with the thermal time constants before treating transient loss as a steady-state wattage.

20. Thermal Time Constants Separate Pulse Stress from Steady-State Heating

τth=RthCth\tau_{th}=R_{th}C_{th}

For a single thermal pole under a step in dissipated power:

T(t)=Tamb+Pθth(1−e−t/τth)T(t)=T_{amb}+P\theta_{th}\left(1-e^{-t/\tau_{th}}\right)

Real transformers have multiple thermal time constants, but the first-order model helps distinguish millisecond electrical events from multi-second or multi-minute thermal heating.

21. Airflow, PCB Copper, Potting, and Enclosure Change Thermal Resistance

Do not reuse a free-air thermal resistance if the product adds forced air, dense PCB copper, metal chassis contact, a plastic enclosure, neighboring hot semiconductors, or a restricted airflow path. Those installation details can materially change winding and core temperatures.

22. Potting Can Improve Conduction and Worsen Other Constraints

Potting or encapsulation can improve conduction from inner windings to the case, but it can also reduce exposed convective area, add dielectric capacitance, lock in mechanical stress, and change service/manufacturing constraints. Model the actual material and geometry rather than assuming potting always improves temperature.

23. Gap Fringing, Shields, and Nearby Metal Add Local Loss

Chapter 9 gap fringing, Chapter 11 electrostatic shields, and Chapter 8 leakage fields can create loss outside the ideal core-plus-copper model. Track those terms in Pother when they are significant.

SOLIDMAG ENGINEERING INSIGHT

Localized Field Loss Can Create the Hotspot without Dominating Total Watts

A small amount of eddy-current loss concentrated in one foil edge or one turn beside the gap can produce the highest local temperature.

Thermal validation should inspect spatial hotspots, not only total transformer loss.

24. Worked Example — Hypothetical Vendor Core-Loss Point

WORKED DESIGN EXAMPLE

Hypothetical Vendor Core-Loss Point

Continue the 500 W / 48 V example. Chapter 9 deliberately did not select a ferrite grade. To demonstrate the thermal calculation only, suppose the eventual vendor material data or validated loss tool returns Pv = 65 kW/m³ for the chosen core at the relevant f/B/T point, and the selected core has Ve = 12 cm³.

The 65 kW/m³ value is hypothetical and is not attributed to any specific ferrite material.

Pcore=(65 kW/m3)(12 cm3)≈0.78 WP_{core}=(65\ \mathrm{kW/m^3})(12\ \mathrm{cm^3})\approx0.78\ \mathrm{W}

25. Worked Example — Hot Primary and Secondary AC Copper Loss

Use the Chapter 10 80 °C hot RDC estimates, then suppose the selected Chapter 11 stack produces RAC/RDC = 1.6 on the primary and 1.8 on the secondary at the loss-critical operating point:

PCu,P≈(2.8)2(1.6)(0.0609)≈0.764 WP_{Cu,P}\approx(2.8)^2(1.6)(0.0609)\approx0.764\ \mathrm{W}
PCu,S≈(10.8)2(1.8)(0.00395)≈0.828 WP_{Cu,S}\approx(10.8)^2(1.8)(0.00395)\approx0.828\ \mathrm{W}

These values make the AC winding geometry visible in the thermal result: the same hot RDC values would have produced only about 0.94 W combined without the AC-resistance multipliers.

26. Worked Example — Total Transformer Loss and Efficiency

Assume an additional 0.15 W for leads, tabs, and terminations and neglect other losses for this educational pass:

Ptr≈0.78+0.764+0.828+0.15≈2.52 WP_{tr}\approx0.78+0.764+0.828+0.15\approx2.52\ \mathrm{W}
ηtr≈500500+2.52≈99.50%\eta_{tr}\approx\frac{500}{500+2.52}\approx99.50\%
Worked 500 W LLC transformer loss stack showing 0.78 W core loss, 0.764 W primary AC copper loss, 0.828 W secondary AC copper loss, and 0.15 W termination loss.

Figure 12-3. Worked 500 W transformer loss stack showing hypothetical core loss, primary AC copper loss, secondary AC copper loss, and termination loss.

27. Worked Example — First-Pass Temperature Rise

For a first-pass effective thermal resistance of 14 K/W and maximum ambient of 50 °C:

Thot≈50+(2.52)(14)≈85.3∘CT_{hot}\approx50+(2.52)(14)\approx85.3^\circ\mathrm{C}

This one-node result is only a screening temperature. The real winding hotspot may be hotter than the average core/case temperature.

28. Worked Example — Iterate Copper Resistance with Temperature

Recalculate copper resistance using the predicted ~85 °C temperature and repeat the winding-loss calculation. In this illustrative iteration, total transformer loss becomes approximately:

Ptr,iter≈2.55 WP_{tr,iter}\approx2.55\ \mathrm{W}
Thot,iter≈50+(2.55)(14)≈85.7∘CT_{hot,iter}\approx50+(2.55)(14)\approx85.7^\circ\mathrm{C}

The small change indicates convergence for this simplified model. A material whose ferrite loss changes strongly around the predicted temperature could require additional iterations.

29. Build a Loss-and-Temperature Matrix across the LLC Operating Window

Cornerfs / Flux TrendCurrent TrendCore-Loss CheckCopper-Loss CheckThermal Result
Low line / full loadLow fs / high BHighPv at low fs, high B, hot TPrimary + secondary RACCalculate
Nominal / full loadNear frHighPv at nominal pointOften high sustained I²RCalculate
High line / full loadHigh fs / lower BModerate/highFrequency-sensitive PvHigher RAC frequency penaltyCalculate
Light loadHigh fs / low currentLowHigh-f loss / burstMagnetizing current + RACCalculate
Startup / overloadTransientPeakFlux transientHigh current energyTransient model
LLC operating-corner matrix comparing switching frequency, peak flux density, RMS winding current, core loss, copper loss, total loss, and estimated temperature rise across low-line, nominal, high-line, light-load, and transient conditions.

Figure 12-4. LLC loss-and-temperature operating-corner matrix linking frequency, flux, current, core loss, copper loss, and temperature.

30. Validate Thermal Models with Hardware Measurements

A thermal model becomes trustworthy only after correlation to hardware. Useful measurements include:

  • Winding resistance before/after heating to infer average copper temperature.
  • Thermocouples embedded at predicted winding and core hotspots.
  • IR imaging where emissivity and line-of-sight permit.
  • Core surface temperature at multiple locations.
  • Input/output power measurement with enough accuracy to resolve transformer loss.
  • Impedance / RAC measurements at temperature where practical.
  • Ambient chamber and airflow-controlled testing.
θth,eff=Thot−TambPtr\theta_{th,eff}=\frac{T_{hot}-T_{amb}}{P_{tr}}

Use measured effective thermal resistance and hotspot offsets to update the automated model for future designs.

  1. Import final core/material candidate, winding stack, current waveforms, RAC/RDC, leakage/fringing geometry, and ambient/cooling requirements.
  2. Calculate core loss at every important f/B/T corner using vendor-supported data.
  3. Calculate hot RDC and frequency-dependent RAC for each winding.
  4. Add lead, termination, shield, fringing, and nearby-metal losses where significant.
  5. Build the total transformer loss budget by corner.
  6. Apply a first-pass thermal model and predict winding/core temperatures.
  7. Recalculate temperature-dependent copper and ferrite losses.
  8. Iterate until temperatures converge.
  9. Check hotspot, insulation, ferrite, bobbin, adhesive, solder, and reliability limits.
  10. Evaluate startup/overload with transient thermal models when required.
  11. Prototype the most promising design.
  12. Measure hotspots, effective thermal resistance, and loss.
  13. Calibrate the thermal model.
  14. Repeat optimization if core/copper loss split or hotspot location is unacceptable.
  15. Release the thermally closed geometry to Chapter 13 for final insulation/EMI validation.
LLC transformer loss-and-thermal closure workflow showing electrical loss modeling, thermal analysis, temperature updates, prototype measurement, model calibration, and final production release.

Figure 12-5. Loss-and-thermal closure workflow from f/B/T core loss and RAC winding loss through thermal iteration, prototype measurement, model calibration, and final release.

32. Design Handoff to Isolation, Insulation, and EMI

Chapter 13 should receive the thermally validated construction because insulation spacing and EMI modifications can change both loss and thermal paths. Provide:

  • Final core/material, turns, gap, and winding stack.
  • Core loss by operating corner.
  • Primary/secondary hot RAC and copper loss.
  • Termination/fringing/shield loss terms.
  • Predicted core and winding hotspots.
  • Maximum ambient and cooling condition.
  • Measured/calibrated thermal resistance where available.
  • Available temperature margin for insulation-system changes.

Chapter 13 now finalizes isolation, insulation, creepage, clearance, shields, and EMI without violating the thermal solution.

33. Chapter 12 Engineering Checklist

  • Core loss uses selected-material f/B/T data.
  • Non-sinusoidal flux is handled with an appropriate method.
  • Core-loss temperature dependence is included.
  • Copper resistance is temperature corrected.
  • RAC/RDC includes skin and proximity effects from the final Chapter 11 stack.
  • Harmonic loss is included where one-frequency RAC is insufficient.
  • Lead and termination loss are included.
  • Gap-fringing, shield, and nearby-metal loss are included where significant.
  • Total transformer loss is broken down by source.
  • Transformer efficiency is calculated.
  • A thermal resistance/network model converts watts to temperatures.
  • Core and winding hotspots are distinguished.
  • Loss and temperature are iterated to convergence.
  • Hotspot margin is checked against the lowest applicable material limit.
  • Low-line, nominal, high-line, light-load, and transient corners are all checked.
  • Burst average loss is duty-cycle weighted.
  • Startup/overload uses transient thermal analysis where necessary.
  • Product airflow, PCB, enclosure, and potting are represented.
  • Thermal model is correlated to hardware before production release.

CHAPTER TAKEAWAY

Thermal Design Is an Iteration, Not a Final Temperature Formula

The winding heats because RAC creates loss; that heating raises copper resistance and changes the loss. Ferrite loss also changes with temperature.

A credible transformer design solves electrical loss and thermal state together, then calibrates the model to hardware.

34. Conclusion — Loss, Temperature, and Geometry Must Be Iterated Together

Chapter 12 closes the efficiency and temperature loop created by every earlier design choice. Core material, turns, flux, gap, conductor, winding stack, leakage target, capacitance, and terminations all appear again as watts and hotspots.

The optimal transformer is not necessarily the design with minimum core loss or minimum copper loss. A slightly larger core may lower ferrite loss but increase winding length; more turns may lower flux but raise copper resistance; aggressive interleaving may lower RAC but add capacitance and insulation complexity. Thermal closure identifies the combination that is physically sustainable.

With loss and temperature now closed, Chapter 13 can finalize the isolation and EMI construction while preserving the electrical and thermal margins already established.

Technical References for This Chapter

The loss and thermal methods in this chapter are consistent with current TDK ferrite-design tooling and Infineon LLC design guidance. Final production designs should use the exact selected material’s loss data, actual winding RAC, and hardware thermal correlation.

RESONANT CONVERTER TRANSFORMER DESIGN

Ready to Design a Resonant Converter Transformer?

Enter your resonant-converter requirements and begin a SolidMagnetics transformer design workflow built around the electrical, magnetic, winding, thermal, mechanical, and manufacturing constraints that shape a practical LLC or related resonant transformer.

Use the design interface to define the converter operating range, transformer requirements, resonant and magnetizing inductance targets, winding priorities, isolation needs, thermal limits, physical constraints, and optimization goals.

Return to the Ultimate Guide to Resonant Converter Transformer Design

READY TO APPLY THIS?

Turn Your Requirements Into a Real Magnetic Design

If you are working on a real inductor, flyback transformer, or supported LLC/resonant transformer project, SolidMagnetics can help you move faster from electrical requirements to calculated magnetic geometry and engineering output.

FOUNDING EARLY ENGINEERING ACCESS: $249   →   $49

Use coupon code EARLYACCESS for the Single Design package. This offer is intended for engineers who want to evaluate the current SolidMagnetics workflow and provide practical feedback that helps improve the platform.

What the Current Package Can Include

  • Requirements and feasibility review
  • Candidate design comparison and recommended design
  • Electrical, magnetic, loss, and thermal calculations
  • SolidWorks Reference CAD and STEP files where supported
  • Drawings, BOM, winding, and engineering data where supported
  • A basis for comparing custom geometry with commercial core and bobbin options

Early Access Offer Details

  • Single Design standard price: $249
  • Early Engineering Access price: $49
  • Coupon code: EARLYACCESS
  • Limited to 10 total qualified paid projects
  • One discounted project per customer
  • Expires February 12, 2027, or when all 10 uses are claimed
  • Brief post-delivery feedback is requested

The standard package provides a Reference CAD representation of the generated design rather than the complete underlying SolidMagnetics parametric automation structure. Fully parametric engineering CAD may be available separately for qualifying advanced or Enterprise projects.

Early Access calculations, CAD, drawings, and related deliverables are intended to accelerate engineering evaluation and prototype development. Final mechanical, electrical, thermal, insulation, regulatory, manufacturing, and production validation remains the responsibility of the customer and their engineering team.

ABOUT THE AUTHOR

Stan Gibson

Electrical Engineer & Founder, SolidMagnetics

Stan Gibson is an electrical engineer and founder of SolidMagnetics, an engineering platform focused on magnetic-component design automation. His work includes power electronics, inductor and transformer design, magnetic-core selection, winding design, thermal analysis, and manufacturable CAD development. Through SolidMagnetics, he develops technical guides, calculators, and automated design tools intended to help engineers move from electrical requirements to practical magnetic-component designs.