Chapter 9 turns the conductor choices from Chapter 8 into a physical winding architecture. Winding order, separation, interleaving, sectioning, overlap, insulation, lead routing, and symmetry determine leakage inductance and coupling while simultaneously affecting AC loss, capacitance, safety spacing, thermal behavior, and manufacturability.
The goal is not automatically the lowest possible leakage. Most converters want leakage reduced to an acceptable level, while resonant topologies may deliberately use controlled transformer leakage. In every case the designer must define the intended leakage/coupling behavior, the physical geometry that creates it, the tolerances that move it, and the measurement method that verifies it.
← Previous Chapter
In This Chapter — Click to Expand
Table of Contents
CHAPTER SCOPE
A General Transformer Winding Framework
This chapter develops winding arrangement, leakage, and coupling principles that apply broadly across high-frequency power transformers. Topology-specific implementations—such as deliberately using transformer leakage as LLC resonant inductance—are identified where they alter the normal design objective.
1. Winding Arrangement Converts Electrical Requirements into Geometry
Chapter 8 selected conductor candidates from RMS current, peak current, copper area, skin depth, proximity effect, hot resistance, window fit, termination, and thermal constraints. Chapter 9 now places those conductors inside the transformer window. The order, spacing, sectioning, overlap, lead exits, insulation thickness, and symmetry of the windings determine how tightly the windings couple and how much leakage inductance the finished transformer exhibits.
Because winding geometry simultaneously changes leakage inductance, AC resistance, capacitance, insulation stress, thermal paths, and manufacturability, winding arrangement is not a drafting step performed after the electrical design. It is part of the electrical design itself.
2. Mutual Flux and Leakage Flux Are Different Parts of the Magnetic Field
The useful transformer action comes from mutual flux that links both primary and secondary windings. Leakage flux links one winding more strongly than another and therefore behaves electrically as series inductance.
Some leakage is unavoidable because real windings occupy finite space. The designer controls leakage by controlling the spatial separation and field path between winding sections.
Figure 9-1. Mutual flux links primary and secondary windings, while leakage flux links the windings unequally and appears electrically as series leakage inductance.
3. Coupling Coefficient Quantifies How Strongly Windings Share Flux
For two windings, the coupling coefficient k relates mutual inductance M to the self-inductances of the two windings. A value near one indicates strong coupling, but no practical transformer achieves exactly unity coupling.
Coupling coefficient is useful for comparison, while leakage inductance is often the more actionable quantity for converter design because it directly affects switching stress, transient energy, commutation, and resonant behavior.
k = M / √(LₚLₛ)
SOLIDMAG ENGINEERING INSIGHT
High Coupling Is Not the Same as Zero Leakage
Coupling coefficient and leakage inductance describe related behavior, but converter stress and resonant behavior are usually easier to close with a leakage-inductance target tied to a defined measurement configuration.
4. Leakage Inductance Is a Geometry-Dependent Series Element
Leakage inductance is not a fixed property of the core material. It depends primarily on winding geometry: separation distance, winding height, layer thickness, section width, overlap, interleaving, lead routing, and the permeability of materials in the leakage field region.
A change that leaves turns ratio and core flux unchanged can still materially change leakage inductance.
Lₗₖ,P ≈ Lₚ(1 − k²)
5. Winding Separation Usually Raises Leakage Inductance
Increasing the radial or axial distance between primary and secondary windings generally increases leakage because a larger field region exists that is linked mainly by one winding.
That separation may be required by insulation, creepage, clearance, margin tape, bobbin geometry, shielding, or manufacturability, so leakage cannot be minimized independently from safety and construction requirements.
DESIGN CAUTION
Do Not Optimize Leakage Before Adding Real Insulation
Margin tape, barriers, sleeving, bobbin walls, triple-insulated wire, and creepage zones change winding separation. A leakage estimate based on an unrealistically tight stack will not survive the safety design.
6. Interleaving Improves Coupling but Creates Tradeoffs
Interleaving splits one or more windings into sections and alternates them so primary and secondary ampere-turns are physically closer. Common arrangements include P-S, P-S-P, S-P-S, and more highly sectioned stacks.
Interleaving can reduce leakage and often reduce external leakage field intensity, but it increases winding interfaces and overlap area. That can increase interwinding capacitance and complicate insulation and manufacturing.

Figure 9-2. Interleaving can improve coupling and reduce leakage, but increased winding interfaces and overlap create capacitance, insulation, and manufacturing tradeoffs.
7. Sectioning Changes Field Distribution Inside the Window
Dividing a winding into multiple series sections can reduce the distance between opposing ampere-turn distributions and reshape the magnetomotive-force profile through the window.
The number of sections, their turns, their series connection, and their physical placement should be treated as controlled design variables rather than informal winding-shop choices.
8. MMF Distribution Explains Why Winding Order Matters
The magnetomotive-force distribution through the winding stack provides an intuitive way to understand leakage and proximity loss. Where primary and secondary ampere-turns cancel locally, the leakage field is reduced. Where large uncancelled ampere-turns remain across a region, the field and stored leakage energy increase.
Plotting MMF across the window is especially useful before committing to foil, planar, or multilayer high-current windings.
9. Leakage Energy Grows with Current Squared
Leakage inductance stores energy whenever current flows. During switching transitions that energy must be transferred, resonated, clamped, or dissipated by the converter.
That is why a leakage value that looks small in microhenries can still create substantial voltage stress at high current.
Eₗₖ = ½ Lₗₖ I²
10. Measure Leakage with a Defined Terminal Configuration
Leakage inductance is commonly measured by shorting one winding and measuring the inductance seen from another winding. For multiwinding transformers, the result depends on which windings are shorted, which are left open, test frequency, fixture inductance, and connection geometry.
A leakage specification without a measurement method is incomplete. Production drawings and test plans should state the exact terminal configuration and frequency.
SOLIDMAG ENGINEERING INSIGHT
Leakage Inductance Without a Test Method Is Not a Complete Specification
State the driven winding, every shorted or open winding, test frequency, fixture method, and terminal points. Otherwise two correct measurements can disagree simply because they used different configurations.

Figure 9-3. Leakage inductance must be specified together with the exact terminal configuration, test frequency, fixture method, and treatment of all other windings.
11. Topology Determines Whether Leakage Is a Problem or a Design Target
In many hard-switched converters, excessive leakage produces unwanted voltage overshoot, snubber loss, duty-cycle loss, and ringing. The usual objective is therefore to reduce leakage while respecting capacitance and safety constraints.
In LLC and related resonant converters, part or all of the required resonant inductance may intentionally be implemented as transformer leakage. In that case the goal is controlled leakage, not minimum leakage.
TOPOLOGY NOTE
Resonant Transformers May Intentionally Use Leakage
For LLC and related resonant converters, the required resonant inductance may be partly or fully integrated into transformer leakage. Refer to the dedicated Ultimate Guide to Resonant Converter Transformer Design for topology-specific allocation and gain implications.
12. Primary and Secondary Placement Must Respect Insulation Boundaries
Electrical isolation can require reinforced or basic insulation, triple-insulated wire, margin tape, split bobbins, sleeving, barriers, controlled creepage paths, or specific layer separations.
These features change winding separation and therefore change leakage. Safety geometry must be included before the final leakage calculation, not added after optimization.
13. Foil, Litz, Round Wire, and Planar Windings Respond Differently to Arrangement
Conductor technology affects how accurately a winding stack can be placed and how fields penetrate the copper. Foil and planar conductors create broad, well-defined layers but can suffer severe proximity loss when field orientation is unfavorable. Litz can reduce strand-scale eddy current loss but does not eliminate proximity loss caused by the overall winding field.
Chapter 8 selected conductor candidates; Chapter 9 must reevaluate them in the actual field environment created by the chosen stack.
14. Lead Routing Is Part of Leakage Design
The active winding window is not the only source of leakage. Long separated leads, crossovers, pin exits, bus bars, and PCB connections can add stray inductance and imbalance.
High-current secondary leads and center-tap connections deserve special attention because even a few millimeters of asymmetric routing can alter commutation and current sharing.
15. Center-Tapped and Parallel Secondary Windings Need Geometric Symmetry
A center-tapped secondary should not merely have equal turn counts; its two halves should see similar coupling, resistance, leakage, termination length, and thermal environment.
Parallel windings likewise require matching geometry. Electrical symmetry begins with physical symmetry.
DESIGN CAUTION
Equal Turns Do Not Guarantee Equal Current Sharing
Parallel or center-tapped windings can have identical turn counts and still share current poorly if their leakage, resistance, lead length, or thermal environment differs.
16. Multiple Outputs Create a Coupling Matrix, Not a Single Leakage Number
In a multi-output transformer, each winding couples differently to every other winding. Cross-regulation, transient response, and rectifier stress can therefore depend on the complete winding arrangement.
The designer may need to prioritize certain coupling pairs and accept weaker coupling for auxiliary outputs.
17. Winding Height and Window Utilization Affect Leakage
A winding that uses the available window height efficiently tends to distribute ampere-turns over a larger opposing area, which can improve coupling. Partial-height windings, concentrated sections, and mismatched winding heights can increase leakage field concentration.
However, extending winding height may conflict with creepage margins, termination zones, and bobbin flange requirements.
18. Manufacturing Tolerances Create Leakage Variation
Tape thickness, wire build, winding tension, layer registration, start/finish position, section placement, bobbin dimensions, and lead dress all shift the physical geometry from unit to unit.
A production-capable design must predict not only nominal leakage but also the tolerance band.
19. FEA Is Valuable When the Geometry Becomes Strongly Coupled
First-order analytical leakage equations are excellent for screening and for understanding trends. Two-dimensional or three-dimensional field analysis becomes increasingly valuable for unusual window shapes, planar structures, complex interleaving, partial-height windings, gaps near conductors, shields, or nearby conductive hardware.
FEA should support—not replace—prototype measurement. The final model should be correlated to a physical part.
20. Worked Arrangement Comparison — P-S versus P-S-P
Consider two candidate stacks using the same core, turns, conductor area, and insulation system. A simple P-S arrangement minimizes interfaces and is easy to manufacture, but it places the entire primary on one side of the secondary. A split-primary P-S-P stack places half of the primary on each side of the secondary, typically improving coupling and reducing leakage.
The P-S-P arrangement usually increases primary-to-secondary overlap area and therefore tends to increase interwinding capacitance. The correct choice depends on the allowed leakage, common-mode current, insulation system, AC loss, and manufacturing complexity.
WORKED DESIGN COMPARISON
P-S-P Trades Leakage for Capacitance
Splitting the primary around the secondary usually reduces leakage by bringing opposing ampere-turns closer together. The added primary-secondary interfaces, however, usually increase capacitive coupling. Chapter 10 evaluates that consequence explicitly.

Figure 9-4. A P-S-P split-primary arrangement generally improves coupling relative to a simple P-S stack, but often increases interwinding capacitance and manufacturing complexity.
21. Freeze the Winding Stack Only After Cross-Checking AC Loss
A winding arrangement that meets the leakage target can still fail because the local leakage field produces excessive proximity loss. Recalculate RAC using the actual layer and section arrangement before releasing the geometry.
This cross-check is especially important for foil, planar copper, and high-current multilayer windings.
22. Define the Chapter 9 Design Outputs
The output of this chapter is a controlled winding architecture: winding order, sectioning, turn allocation by section, conductor type, insulation between sections, overlap length, winding height, lead exits, expected leakage inductance, coupling targets, and the specified leakage test method.
Those outputs become direct inputs to Chapter 10, where the same geometry is analyzed for parasitic capacitance, common-mode displacement current, electrostatic shielding, and EMI.
23. Recommended Winding Arrangement Workflow
A repeatable workflow prevents leakage from being optimized in isolation. Start from the Chapter 8 conductor candidates and safety boundaries, create several physically buildable stacks, estimate leakage and coupling, check AC loss and symmetry, then refine the best candidates with FEA and prototype measurements where needed.
- Import the Chapter 8 conductor candidates and insulated dimensions.
- Lock required safety boundaries, margins, and bobbin constraints.
- Create at least two physically buildable winding-stack candidates.
- Estimate leakage inductance and coupling for each candidate.
- Check winding-height utilization and MMF distribution.
- Recalculate proximity-effect and AC-resistance risk in the actual stack.
- Check center-tap, parallel-winding, and lead-routing symmetry.
- Include manufacturing tolerances in the leakage prediction.
- Use FEA where analytical geometry assumptions become weak.
- Prototype and measure leakage using a defined terminal configuration.
- Freeze the stack geometry and hand it to Chapter 10 for capacitance and EMI analysis.

Figure 9-5. Winding-arrangement workflow from conductor candidates through leakage, coupling, AC-loss, safety, symmetry, tolerance, and measured validation before handoff to parasitic-capacitance and EMI analysis.
24. Chapter 9 Engineering Checklist
Before leaving Chapter 9, verify that winding order, sectioning, overlap, insulation, conductor dimensions, leads, termination geometry, symmetry, leakage target, tolerance, and measurement method have all been defined.
- Winding order and sectioning are defined.
- Turns per section are documented.
- Conductor type and insulated dimensions are fixed.
- Interlayer and interwinding insulation are included in the geometry.
- Primary-secondary overlap and separation are controlled.
- Winding height and margin regions are defined.
- Lead exits and termination routing are included.
- Center-tapped or parallel paths are geometrically symmetric.
- Nominal leakage and allowed tolerance are specified.
- The leakage measurement terminal configuration and frequency are specified.
- RAC/proximity loss has been rechecked using the actual stack.
- The final geometry is ready for Chapter 10 parasitic-capacitance and EMI analysis.
CHAPTER TAKEAWAY
The Best Winding Stack Is the One That Closes the Whole Design
Do not select a stack because it has the smallest leakage number. Select the stack that meets leakage or coupling requirements while also satisfying AC loss, insulation, capacitance, thermal, symmetry, tolerance, and manufacturing constraints.
25. Conclusion — Winding Geometry Is an Electrical Design Variable
The final winding arrangement determines how closely the real transformer approaches the ideal coupled model. Leakage inductance, coupling coefficient, proximity field, capacitance, safety spacing, thermal paths, and manufacturability all emerge from the same physical geometry.
A successful design therefore does not minimize one parasitic at the expense of every other requirement. It chooses a buildable winding stack that closes the complete converter requirement set.
Technical References for This Chapter
The winding-arrangement methods in this chapter follow established magnetic-component design practice for leakage inductance, coupling, proximity effect, interleaving, and transformer construction. Final designs should correlate analytical or FEA predictions with prototype impedance measurements.
- Texas Instruments — Designing Planar Magnetics.
- Würth Elektronik — Transformer Design for EMC.
- P. L. Dowell, “Effects of Eddy Currents in Transformer Windings,” Proceedings of the IEE, 1966.
- E. C. Snelling, Soft Ferrites: Properties and Applications.
- R. W. Erickson and D. Maksimović, Fundamentals of Power Electronics.
Related SolidMagnetics Resources
Ultimate Guide to Transformer Design
Return to the complete 15-chapter transformer-design roadmap.
Chapter 8 — Winding Current and Conductor Selection
Review RMS/peak current, copper area, hot DCR, skin depth, conductor technology, and preliminary AC-loss constraints.
Chapter 10 — Parasitic Capacitance, Common-Mode Current, and EMI
Continue from the frozen winding stack into capacitance, dv/dt displacement current, shielding, common-mode paths, and EMI.
Ultimate Guide to Resonant Converter Transformer Design
See the topology-specific case where transformer leakage may intentionally realize part or all of resonant inductance.
Ultimate Guide to Flyback Transformer Design
See winding, leakage, clamp, insulation, and energy-storage considerations specific to flyback transformers.
RESONANT CONVERTER TRANSFORMER DESIGN
Ready to Design a Resonant Converter Transformer?
Enter your resonant-converter requirements and begin a SolidMagnetics transformer design workflow built around the electrical, magnetic, winding, thermal, mechanical, and manufacturing constraints that shape a practical LLC or related resonant transformer.
Use the design interface to define the converter operating range, transformer requirements, resonant and magnetizing inductance targets, winding priorities, isolation needs, thermal limits, physical constraints, and optimization goals.
Return to the Ultimate Guide to Resonant Converter Transformer Design