Chapter 8: Resonant Inductance and Controlled Transformer Leakage

Chapter 7 bounded the transformer magnetizing inductance Lm. Chapter 8 now addresses the other inductive quantity that can be intentionally built into an LLC transformer: resonant inductance through controlled leakage. In an integrated design, leakage is no longer simply an unwanted parasitic to minimize—it becomes a specified electrical parameter that winding geometry and manufacturing must reproduce.

This chapter explains how to allocate the Chapter 4 Lr target between external inductance and transformer leakage, how primary and secondary leakage appear in the equivalent circuit, how to measure leakage without double-counting it, how winding separation and interleaving control the result, how parasitic capacitance and AC loss trade against leakage, and how to turn the electrical target into a repeatable production specification.

In This Chapter — Click to Expand

Table of Contents

DESIGN ASSUMPTION

Defined Leakage Model and Measurement Convention

This chapter distinguishes between physical T-model leakage elements, a primary-referred effective leakage used in the resonant model, and a short-circuit leakage value measured at transformer terminals.

Those quantities can be related, but they must not be added together indiscriminately. When an integrated transformer has significant primary and secondary leakage, use a transformer model that preserves both sides or a measurement/modeling method validated against the actual converter.

1. Leakage Inductance Can Be an Intentional LLC Design Variable

In many power transformers, leakage inductance is minimized because it causes voltage spikes, regulation error, and stored energy that must be dissipated elsewhere. LLC design can reverse that objective: the transformer’s leakage field can supply some or all of the series resonant inductance Lr.

That integration can eliminate a separate magnetic component, reduce part count, and improve power density. It also makes winding geometry part of the converter tuning and moves leakage tolerance from a nuisance parameter into the production specification.

SOLIDMAG ENGINEERING INSIGHT

Leakage Is Only Useful When It Is Controlled

An uncontrolled parasitic is not the same thing as an intentional resonant element.

Integrated LLC magnetics require a target leakage value, a measurement method, a tolerance, and a winding structure that reproduces all three.

2. Define the Total Resonant-Inductance Requirement

A first-pass scalar allocation of the total series resonant inductance is:

Lr,total=Lr,ext+Llk,effL_{r,total}=L_{r,ext}+L_{lk,eff}

Therefore the required external inductance is:

Lr,ext=Lr,total−Llk,effL_{r,ext}=L_{r,total}-L_{lk,eff}

The equation is an allocation statement, not a complete transformer model. Llk,eff must be defined consistently with the electrical model and measurement method.

3. External, Integrated, and Hybrid Lr Architectures

ArchitectureTransformer ObjectiveAdvantagesChallenges
External LrLow, bounded leakageIndependent tuning; easier leakage tolerance; transformer can emphasize couplingExtra magnetic part, copper/core loss, cost, and board area
Integrated LrTransformer leakage intentionally supplies most/all LrFewer magnetic components; high integration and power densityLeakage tolerance, stray field, capacitance, winding geometry, and modeling become critical
HybridTransformer supplies part of LrBalances integration and adjustabilityTolerance must be allocated between external and transformer contributions

onsemi has documented cases where an external resonant inductor is deliberately preferred because a high-leakage transformer creates large stray fields near a metal cover and uses winding-window area inefficiently. The best architecture is therefore application dependent.

Three LLC resonant-inductance architectures comparing a discrete external Lr, transformer leakage-derived Lr, and a hybrid split between external inductance and controlled transformer leakage.

Figure 8-1. External, integrated-leakage, and hybrid LLC resonant-inductance architectures.

4. Coupled-Inductor Fundamentals Behind Leakage

For a linear two-winding coupled-inductor model with primary self-inductance LP, secondary self-inductance LS, and mutual inductance M, coupling coefficient is:

k=MLPLSk=\frac{M}{\sqrt{L_PL_S}}
0≤k≤10\le k\le1

Perfect coupling would have k = 1 and zero idealized leakage. Real transformers always have k below one because not all field flux links both windings.

5. Primary Short-Circuit Leakage and Coupling Coefficient

In the same ideal linear coupled-inductor model, the primary inductance measured with the secondary perfectly shorted is:

Llk,P=LP−M2LS=LP(1−k2)L_{lk,P}=L_P-\frac{M^2}{L_S}=L_P(1-k^2)

If LP is measured open-circuit and Llk,P is measured with the secondary shorted, coupling can be estimated as:

k=1−Llk,PLPk=\sqrt{1-\frac{L_{lk,P}}{L_P}}

ENGINEERING CAUTION

The Simple Coupled-Inductor Formula Is a Measurement Model, Not the Whole LLC Equivalent Circuit

It is useful for understanding coupling and terminal measurements.

When leakage is a large fraction of transformer inductance, secondary leakage and the selected ideal-transformer/T-model representation can materially change the resonant model. Use the full integrated-transformer model for converter prediction.

6. Secondary Leakage Must Be Referred Correctly

If a physical secondary leakage element LσS is explicitly represented in a T-model, its value referred to the primary is:

LσS′=n2LσSL_{\sigma S}’=n^2L_{\sigma S}

A first-order sum of explicit primary and primary-referred secondary series leakage elements is then:

Llk,ΣP≈LσP+n2LσSL_{lk,\Sigma P}\approx L_{\sigma P}+n^2L_{\sigma S}

This is useful when working with a physical T-equivalent model. onsemi specifically warns that secondary leakage cannot be ignored in an integrated LLC transformer because it changes the effective resonant behavior.

7. Do Not Double-Count a Measured Short-Circuit Leakage Value

A primary short-circuit leakage measurement already reflects the secondary’s coupled effect into the primary-terminal measurement. If that measured value is used directly as the model’s effective Lr, do not add a separately referred secondary leakage to it again unless the chosen model explicitly requires that decomposition.

ENGINEERING CAUTION

Avoid Leakage Double Counting

Either use a validated terminal-measurement-based effective Lr model, or use explicit primary and secondary leakage elements in a T-model.

Do not combine both approaches by summing the same physical leakage energy twice.

8. Integrated Transformers Require the Correct Equivalent Circuit

TI has shown that a simple LLC model can predict switching frequency poorly when an integrated transformer has significant leakage and coupling is no longer close to ideal. In that case, the transformer should be represented with the appropriate primary and secondary leakage model rather than assuming one lumped Lr and an ideal transformer.

  • Use the simple Lr–Lm model for first-pass normalized design when it has been shown to match the hardware.
  • Use an integrated transformer equivalent circuit when leakage is a substantial fraction of transformer inductance.
  • Include secondary leakage when it affects the active rectifier path.
  • Validate the chosen model against measured switching frequency and tank current on a prototype.
Comparison of a simple LLC equivalent circuit with lumped resonant inductance Lr and an integrated-transformer T-model with primary leakage, magnetizing inductance Lm, ideal transformer ratio, and secondary leakage inductance.

Figure 8-2. Simple LLC model versus integrated-transformer model with separate primary and secondary leakage inductances.

9. Resonant Capacitance Can Be Recalculated from Measured Leakage

If measured transformer leakage is intentionally used as Lr, the resonant capacitor can be recalculated from the measured inductance and target resonant frequency:

Cr=14π2Lrfr2C_r=\frac{1}{4\pi^2L_rf_r^2}

The resulting resonance remains:

fr=12πLrCrf_r=\frac{1}{2\pi\sqrt{L_rC_r}}

TI’s UCC25800-Q1 application guidance uses this measurement-first approach: measure leakage from the resonant side with the opposite side shorted, then choose the resonant capacitance from the measured Lk and desired resonance.

10. Leakage Tolerance Moves the Resonant Frequency

Leakage and resonant-capacitor tolerance both move the actual resonant frequency. For small variations:

Δfrfr≈−12(ΔLrLr+ΔCrCr)\frac{\Delta f_r}{f_r}\approx-\frac{1}{2}\left(\frac{\Delta L_r}{L_r}+\frac{\Delta C_r}{C_r}\right)

If leakage supplies most of Lr, winding and assembly tolerances become resonant-frequency tolerances. That is a major difference from a conventional transformer where leakage may only have an upper limit.

SOLIDMAG ENGINEERING INSIGHT

Leakage Tolerance Becomes a Frequency-Control Tolerance

An integrated LLC transformer must hold leakage tightly enough that the controller’s gain and switching-frequency margins remain valid.

The production leakage tolerance should therefore come from converter analysis, not from an arbitrary transformer-manufacturing percentage.

11. Leakage Is Stored Magnetic-Field Energy Outside Ideal Coupling

Leakage inductance is a convenient circuit representation of magnetic-field energy that does not participate in ideal mutual coupling. For current I:

Wlk=12LlkI2W_{lk}=\frac{1}{2}L_{lk}I^2

Equivalently:

Llk=2WlkI2L_{lk}=\frac{2W_{lk}}{I^2}

The field-energy viewpoint can be expressed as:

Wlk=12∫Vμ0H2dVW_{lk}=\frac{1}{2}\int_V\mu_0H^2\,dV

This viewpoint is useful for CAD/FEA automation because it connects a 3D winding geometry directly to the leakage energy and therefore to an equivalent inductance.

12. Winding Separation Is a Direct Leakage-Control Knob

Increasing physical separation between primary and secondary generally increases leakage because a larger region of magnetic field exists between windings without linking both equally.

  • Increase radial insulation thickness between primary and secondary.
  • Use separate winding chambers or a sectional bobbin.
  • Reduce axial overlap between winding sections.
  • Move windings toward opposite sides of the window.
  • Change section order or number of winding subsections.

Those same changes can reduce primary-secondary capacitance, but they consume window area and can increase mean turn length or AC loss.

13. Interleaving Reduces Leakage but Usually Raises Capacitance

Interleaving increases the overlap between primary and secondary fields and therefore normally improves coupling and reduces leakage. A split-primary structure such as P/2–S–P/2 is a common example.

More Interleaving Tends ToLess Interleaving / More Separation Tends To
Reduce leakage inductanceIncrease leakage inductance
Reduce some proximity-loss mechanisms when current distribution improvesPotentially increase local leakage-field proximity loss
Increase primary-secondary overlap capacitanceReduce primary-secondary capacitance
Make integrated high-Lr targets harderMake integrated Lr easier to achieve
Add winding complexity and section transitionsSimplify some sectioning but may consume more window width

SOLIDMAG ENGINEERING INSIGHT

Minimum Leakage Is Not the Goal for an Integrated LLC Transformer

Interleaving should be chosen to hit the required leakage while keeping AC loss and capacitance acceptable.

The correct winding is a compromise, not the construction with the highest possible coupling.

LLC transformer winding geometry comparison showing primary-secondary, split-primary P/2-S-P/2, and separated-chamber constructions with their leakage inductance and interwinding capacitance tradeoffs.

Figure 8-3. Winding-geometry comparison showing high interleaving/low leakage/high capacitance versus separated windings/high leakage/lower capacitance.

14. Sectional Bobbins and Split Windings Change the Trade Space

Sectional bobbins, split windings, and deliberate non-overlap can create controlled leakage without relying on a separate resonant inductor. They also change the electric-field and manufacturing problem.

  • Section chamber width tolerance.
  • Insulation barrier thickness.
  • Actual layer buildup.
  • Lead crossover location.
  • Winding axial placement and centering.
  • Bobbin molding tolerance.

For a leakage-critical design, these dimensions should be treated as electrical dimensions, not only mechanical dimensions.

15. Core, Bobbin, and Nearby Metal Affect Leakage Fields

Leakage flux extends outside the ideal core path. Nearby conductive hardware can therefore intercept that field and develop eddy-current loss. onsemi has documented an LLC case where a metal cover located close to a high-leakage transformer made an external shielded resonant inductor preferable.

  • Metal enclosure distance.
  • Copper planes under or around the transformer.
  • Core clamps or conductive mounting hardware.
  • Magnetic shields or flux bands.
  • Air gap location and fringing field.

ENGINEERING CAUTION

A Leakage Target Can Change After the Transformer Is Installed in the Product

Nearby metal can alter stray-field loss and sometimes the effective resonant behavior.

Validate integrated-leakage magnetics in the intended mechanical environment, not only on an open bench.

EARLY ENGINEERING ACCESS

Get Your First Custom Magnetic Design for $49

Need a custom inductor, flyback transformer, or currently supported LLC/resonant transformer design for a real project? SolidMagnetics Early Engineering Access gives you a lower-cost way to evaluate the platform while it continues to expand.

STANDARD SINGLE DESIGN PRICE: $249   •   EARLY ACCESS PRICE: $49

Use coupon code EARLYACCESS. Your supported design package can include:

  • Candidate magnetic design output and recommended design direction
  • SolidWorks Reference CAD and STEP export where supported
  • Engineering drawings, BOM, winding, and design data where supported
  • A practical starting point for component matching, simulation, prototyping, or further development

Offer details: Limited to the first 10 qualified paid projects. One discounted project per customer. Expires February 12, 2027, or when all 10 uses are claimed, whichever comes first.

SolidMagnetics-generated designs are engineering starting points intended to accelerate development. Final component selection, manufacturability, tolerances, winding construction, insulation, creepage and clearance, thermal performance, regulatory requirements, and production suitability must be verified for the intended application.

16. Lead Routing and PCB Inductance Can Become Part of Lr

The resonant current path includes transformer leads, PCB traces, vias, connector structures, and any external resonant inductor. If the design model intends to use total power-stage inductance, a useful bookkeeping relation is:

Llk,board=Llk,xfmr+Lstray,pcbL_{lk,board}=L_{lk,xfmr}+L_{stray,pcb}

Decide whether the transformer production specification excludes PCB stray inductance while system tuning includes it, or whether a board-level measurement is used to capture both. TI notes that in-circuit measurements can be useful specifically because they include power-stage parasitics.

17. Center-Tapped and Multiple Secondaries Need Leakage-Balance Checks

Center-tapped and multiple-secondary LLC transformers can have different leakage values for different active secondary paths. That mismatch can make the resonant tank different on alternating half cycles.

ΔLimb=|Llk,S1′−Llk,S2′|\Delta L_{imb}=|L_{lk,S1}’-L_{lk,S2}’|

A normalized mismatch metric is:

εimb=ΔLimbLlk,avg×100%\varepsilon_{imb}=\frac{\Delta L_{imb}}{L_{lk,avg}}\times100\%

ST’s recent LLC transformer specification measures leakage with one secondary shorted and requires the difference between the two measured leakage values to stay below a defined limit. This is a strong production practice for center-tapped or dual-path secondaries.

18. Define the Leakage Measurement Method Before Manufacturing

A leakage value without a test method is incomplete. The production specification should state:

  • Driven winding and exact test terminals.
  • Which opposite winding or winding section is shorted.
  • Whether one secondary is shorted at a time or all secondaries are shorted.
  • Test frequency.
  • Test amplitude.
  • Fixture and lead compensation.
  • Reference temperature.
  • Core clamp / assembly condition.
  • Whether the measurement is transformer-only or in-circuit.

The production leakage range can be written as:

Llk,spec=Llk,nom±ΔLlkL_{lk,spec}=L_{lk,nom}\pm\Delta L_{lk}

A useful normalized half-range is:

δlk=Llk,max⁡−Llk,min⁡2Llk,nom\delta_{lk}=\frac{L_{lk,\max}-L_{lk,\min}}{2L_{lk,nom}}

19. When FEA or Field-Energy Extraction Becomes Valuable

Analytical leakage formulas are useful for first-pass design, but complex interleaving, foil, planar windings, shields, sectional bobbins, asymmetric secondaries, and nearby metal can make a field solution more valuable.

  • Extract leakage energy from a 2D or 3D magnetic field model.
  • Sweep winding spacing and overlap parametrically.
  • Map high leakage-field regions into conductor proximity-loss models.
  • Estimate the effect of shields or conductive hardware.
  • Use measured prototype data to calibrate the model.

The field-energy equations above are especially suitable for CAD-linked automation because geometry changes can be converted into leakage-inductance predictions before a physical transformer is wound.

20. Worked Example — Allocate the Chapter 4 Lr Target

WORKED DESIGN EXAMPLE

Allocate the Chapter 4 Lr Target

Continue the 500 W / 48 V design thread: total resonant inductance Lr,total = 31.7 µH, Cr ≈ 35.5 nF, fr ≈ 150 kHz, and Chapter 7 Lm ≈ 158.5 µH.

Three architectures are compared using the same total target. The leakage values are illustrative architecture targets, not final winding designs.

Lr,total=31.7 μHL_{r,total}=31.7\ \mu\mathrm{H}

External-Lr candidate: assume transformer effective leakage is limited to 3.0 µH:

Lr,ext=31.7−3.0=28.7 μHL_{r,ext}=31.7-3.0=28.7\ \mu\mathrm{H}

Hybrid candidate: intentionally design 11.7 µH of effective transformer leakage:

Lr,ext=31.7−11.7=20.0 μHL_{r,ext}=31.7-11.7=20.0\ \mu\mathrm{H}

Integrated candidate: target the full 31.7 µH through the validated transformer leakage model and use no separate Lr.

For any candidate that preserves total Lr = 31.7 µH and fr = 150 kHz, the nominal Cr remains:

Cr=14π2(31.7 μH)(150000)2≈35.5 nFC_r=\frac{1}{4\pi^2(31.7\ \mu\mathrm{H})(150\,000)^2}\approx35.5\ \mathrm{nF}

21. Worked Measurement Example — Estimate Coupling from Lopen and Lshort

Suppose an illustrative two-winding prototype measures LP = 180 µH with the secondary open and Llk,P = 31.7 µH with the secondary shorted. The ideal linear coupled-inductor estimate gives:

k=1−31.7180≈0.908k=\sqrt{1-\frac{31.7}{180}}\approx0.908

A coupling coefficient around 0.91 is intentionally far from an ideal transformer and illustrates why the full integrated-transformer model may be necessary.

ENGINEERING CAUTION

Do Not Automatically Compute LLC Lm as Lopen − Lshort in a Strongly Integrated Transformer

That shortcut can be useful in some simplified models but may not preserve the separate primary and secondary leakage behavior needed for accurate LLC prediction.

Use the model associated with the converter analysis and validate it against measured switching behavior.

22. Tolerance Example — Lr and Cr Move fr

Assume the integrated Lr target and Cr are each controlled to ±5%. The nominal resonance is 150 kHz. A first-order estimate predicts approximately ±5% resonant-frequency shift when both tolerances move in the same direction.

fr,min≈1501.05=142.9 kHzf_{r,min}\approx\frac{150}{1.05}=142.9\ \mathrm{kHz}
fr,max≈1500.95=157.9 kHzf_{r,max}\approx\frac{150}{0.95}=157.9\ \mathrm{kHz}

The controller and gain analysis must tolerate that resonant-frequency movement. If the leakage tolerance is wider than the capacitor tolerance, leakage manufacturing can become the dominant frequency uncertainty.

23. Compare External, Integrated, and Hybrid Candidates

CandidateTransformer Leakage TargetExternal LrLikely StrengthLikely Risk
External≤ 3.0 µH example≈ 28.7 µHIndependent tuning; low stray transformer fieldExtra magnetic component
Hybrid≈ 11.7 µH example≈ 20.0 µHModerate integration with tuning freedomTwo tolerance contributors
Integrated≈ 31.7 µH effective target0Minimum magnetic part countHardest leakage/capacitance/model/manufacturing control

SOLIDMAG ENGINEERING INSIGHT

Architecture Is an Optimization Variable

The fully integrated transformer is not automatically superior.

External or hybrid Lr can be the better engineering choice when leakage tolerance, metal proximity, EMI, winding loss, or manufacturability dominate.

Comparison of external, hybrid, and integrated LLC resonant-inductance architectures for a 31.7 microhenry Lr target, showing transformer leakage contribution, external inductor value, capacitance, leakage field, and manufacturing control.

Figure 8-4. Worked architecture comparison for the 31.7 µH Lr target: external, hybrid, and integrated transformer leakage.

24. Production Leakage Specification and Acceptance Limits

A production leakage specification should be written so two different factories or test technicians obtain the same electrical result.

Specification FieldExample Requirement
ParameterPrimary leakage inductance / effective resonant leakage.
TerminalsPrimary pins X–Y.
Short conditionSpecified secondary half or complete secondary shorted.
Test frequencyDefined frequency such as 100 kHz or application-specific value.
Test amplitudeDefined small-signal voltage/current.
ToleranceTarget ± defined percentage.
BalanceMaximum mismatch between active secondary paths if applicable.
FixtureDefined lead/fixture compensation.
Reference temperatureSpecified production condition.

If an external resonant inductor is trimmed or selected to compensate transformer leakage, the tolerance allocation may be treated as complementary:

ΔLr,ext≈−ΔLlk,eff\Delta L_{r,ext}\approx-\Delta L_{lk,eff}

That approach can reduce total-Lr variation but adds component-selection or tuning complexity.

  1. Import total Lr, Cr, fr, Lm, n, and gain/frequency requirements from Chapters 4–7.
  2. Choose external, integrated, or hybrid Lr architecture.
  3. Define exactly what leakage quantity the electrical model requires.
  4. Build a transformer equivalent circuit that includes secondary leakage when significant.
  5. Allocate the total Lr target between external inductance and transformer leakage.
  6. Choose an initial winding arrangement and insulation spacing.
  7. Estimate leakage analytically or with field-energy/FEA methods.
  8. Estimate interwinding capacitance and AC-loss consequences of the same geometry.
  9. Generate several geometry candidates rather than one nominal winding.
  10. Prototype or simulate the most promising candidates.
  11. Measure leakage with the exact intended production method.
  12. Calibrate the model against measured resonant frequency and switching behavior.
  13. Apply leakage, Cr, and assembly tolerances and regenerate the gain/frequency map.
  14. Check secondary-path leakage balance where applicable.
  15. Freeze the winding geometry dimensions that materially control leakage.
  16. Release a production leakage specification with terminals, shorting condition, frequency, amplitude, fixture, tolerance, and balance limits.
Controlled transformer leakage design workflow showing total Lr allocation, equivalent circuit modeling, winding geometry, FEA, capacitance and loss tradeoffs, prototype measurement, tolerance analysis, and production specification.

Figure 8-5. Controlled transformer-leakage workflow from total Lr allocation through equivalent circuit, winding geometry, FEA, capacitance/loss tradeoffs, prototype measurement, tolerance, and production specification.

26. Design Handoff to Core, Turns, and Flux

At the end of Chapter 8, the magnetic design should provide Chapter 9 with both inductive targets and enough geometry constraints to begin selecting core, turns, and flux.

  • Lm nominal/min/max from Chapter 7.
  • Total Lr nominal/min/max.
  • External, integrated, or hybrid Lr allocation.
  • Target transformer leakage and measurement method.
  • Primary/secondary leakage model used in converter simulation.
  • Provisional winding separation/interleaving constraints.
  • Primary-secondary capacitance target or upper limit.
  • Any secondary-path leakage-balance requirement.
  • Nearby-metal or mechanical constraints that affect stray fields.

Chapter 9 now selects the core, material, and absolute turns while checking flux density and saturation margin.

27. Chapter 8 Engineering Checklist

  • Total Lr target is defined.
  • External/integrated/hybrid Lr architecture is defined.
  • The effective leakage quantity used by the electrical model is clearly defined.
  • Secondary leakage is included when significant.
  • Measured short-circuit leakage is not double-counted with explicit T-model leakage elements.
  • Cr has been recalculated from the realized/measured Lr where appropriate.
  • Lr and Cr tolerance effects on fr have been checked.
  • Winding separation/interleaving has been evaluated for leakage, capacitance, and AC loss together.
  • Nearby metal and PCB conductors have been considered.
  • Lead/PCB stray inductance is included or explicitly excluded from the leakage model.
  • Center-tapped / multiple-secondary leakage balance has been checked.
  • Leakage measurement terminals and shorting conditions are defined.
  • Test frequency, amplitude, fixture, and temperature are defined.
  • FEA or field-energy extraction is used where geometry is too complex for reliable first-pass formulas.
  • The final leakage target is manufacturable with sufficient tolerance margin.

CHAPTER TAKEAWAY

Controlled Leakage Requires One Consistent Chain from Geometry to Measurement to Model

The same physical leakage field must be represented consistently in CAD/FEA, terminal measurement, resonant-tank equations, and production testing.

Most integrated-LLC errors occur when those four views use different definitions of ‘leakage inductance.’

28. Conclusion — Leakage Must Be Designed, Measured, and Modeled Consistently

LLC resonant inductance can be implemented as a separate inductor, transformer leakage, or a hybrid of both. The integrated approach can reduce part count and improve power density, but it makes leakage an intentional manufacturing parameter and requires a more complete transformer model when secondary leakage is significant.

Winding separation, interleaving, sectioning, insulation thickness, bobbin geometry, lead routing, and nearby metal all affect the leakage field. Those same changes also affect capacitance, AC loss, isolation, and thermal behavior.

With the resonant-inductance architecture and leakage target now defined, Chapter 9 can select the actual core, turns, and flux-density operating point that realizes Lm and the chosen leakage structure without violating saturation or loss limits.

Technical References for This Chapter

The integrated-transformer and leakage-measurement guidance in this chapter is consistent with manufacturer LLC application material from TI, onsemi, and ST. Final designs should validate the chosen equivalent circuit and measurement method against the actual converter hardware.

RESONANT CONVERTER TRANSFORMER DESIGN

Ready to Design a Resonant Converter Transformer?

Enter your resonant-converter requirements and begin a SolidMagnetics transformer design workflow built around the electrical, magnetic, winding, thermal, mechanical, and manufacturing constraints that shape a practical LLC or related resonant transformer.

Use the design interface to define the converter operating range, transformer requirements, resonant and magnetizing inductance targets, winding priorities, isolation needs, thermal limits, physical constraints, and optimization goals.

Return to the Ultimate Guide to Resonant Converter Transformer Design

READY TO APPLY THIS?

Turn Your Requirements Into a Real Magnetic Design

If you are working on a real inductor, flyback transformer, or supported LLC/resonant transformer project, SolidMagnetics can help you move faster from electrical requirements to calculated magnetic geometry and engineering output.

FOUNDING EARLY ENGINEERING ACCESS: $249   →   $49

Use coupon code EARLYACCESS for the Single Design package. This offer is intended for engineers who want to evaluate the current SolidMagnetics workflow and provide practical feedback that helps improve the platform.

What the Current Package Can Include

  • Requirements and feasibility review
  • Candidate design comparison and recommended design
  • Electrical, magnetic, loss, and thermal calculations
  • SolidWorks Reference CAD and STEP files where supported
  • Drawings, BOM, winding, and engineering data where supported
  • A basis for comparing custom geometry with commercial core and bobbin options

Early Access Offer Details

  • Single Design standard price: $249
  • Early Engineering Access price: $49
  • Coupon code: EARLYACCESS
  • Limited to 10 total qualified paid projects
  • One discounted project per customer
  • Expires February 12, 2027, or when all 10 uses are claimed
  • Brief post-delivery feedback is requested

The standard package provides a Reference CAD representation of the generated design rather than the complete underlying SolidMagnetics parametric automation structure. Fully parametric engineering CAD may be available separately for qualifying advanced or Enterprise projects.

Early Access calculations, CAD, drawings, and related deliverables are intended to accelerate engineering evaluation and prototype development. Final mechanical, electrical, thermal, insulation, regulatory, manufacturing, and production validation remains the responsibility of the customer and their engineering team.

ABOUT THE AUTHOR

Stan Gibson

Electrical Engineer & Founder, SolidMagnetics

Stan Gibson is an electrical engineer and founder of SolidMagnetics, an engineering platform focused on magnetic-component design automation. His work includes power electronics, inductor and transformer design, magnetic-core selection, winding design, thermal analysis, and manufacturable CAD development. Through SolidMagnetics, he develops technical guides, calculators, and automated design tools intended to help engineers move from electrical requirements to practical magnetic-component designs.