Chapter 7: Magnetizing Inductance — Lm, Gain, Circulating Current, and ZVS

Chapter 6 selected the transformer turns ratio and showed how that integer ratio feeds back into the LLC gain and reflected-load model. Chapter 7 now focuses on magnetizing inductance Lm—the transformer parameter that directly shapes the LLC gain characteristic while also controlling magnetizing current, circulating current, conduction loss, lower characteristic resonance, and primary-side ZVS margin.

The central design tradeoff is simple to state but difficult to optimize: reducing Lm provides more gain and more commutation current, but raises primary circulating/RMS current and conduction loss; increasing Lm reduces that current, but can reduce available gain and make light-load ZVS harder to maintain. The best Lm is therefore the value that satisfies gain, frequency range, ZVS, current, loss, thermal, and manufacturability requirements together.

In This Chapter — Click to Expand

DESIGN ASSUMPTION

Chapter 4 / Chapter 6 LLC Convention

This chapter continues the guide convention Ln = Lm/Lr and n = NP/NS. Quality factor remains Q = Zr/Rac.

Some manufacturer documents use m = (Lr + Lm)/Lr = 1 + Ln. This chapter explicitly translates between the two so the external guidance can be compared without changing the internal SolidMagnetics notation.

Near-resonance magnetizing-current equations are used as first-pass estimates only; final current and ZVS margin must be verified with the actual switching waveforms and device output-charge behavior.

1. Magnetizing Inductance Is an LLC System Parameter

In a conventional transformer, magnetizing inductance is often treated mainly as a no-load-current parameter that should be made large enough to avoid excessive excitation current. In an LLC converter, that view is incomplete because Lm is one of the intentional resonant-tank parameters.

Lm changes the gain curve, the lower characteristic resonance, magnetizing current, primary circulating current, and the energy/current available during dead time for primary-side MOSFET commutation.

SOLIDMAG ENGINEERING INSIGHT

Lm Is Not a Parasitic to Maximize Away

The correct Lm is chosen at the converter level and then realized by the transformer.

A transformer with excellent coupling and very high magnetizing inductance can still be the wrong transformer if the converter no longer reaches its gain target or loses ZVS margin.

2. Keep the Ln Convention Consistent

The inductance ratio used throughout this guide is:

Ln=LmLrL_n=\frac{L_m}{L_r}

Therefore:

Lm=LnLrL_m=L_nL_r

When Lr is fixed, selecting Ln is equivalent to selecting Lm. That is why Chapter 4 treated Ln as a gain-shaping coordinate and Chapter 7 treats Lm as the physical transformer target.

3. Translate Between Ln and the Alternative m Ratio

Infineon and other LLC references often use the ratio m defined from total primary inductance to resonant inductance. With this guide’s notation:

m=Lr+LmLr=1+Lnm=\frac{L_r+L_m}{L_r}=1+L_n
This GuideAlternative Manufacturer Notation
Ln = 5m = 6
Ln = 3.5m = 4.5
Ln = 8m = 9

ENGINEERING CAUTION

Do Not Compare Ln and m as Though They Were the Same Number

The two ratios differ by one under these definitions.

Before copying a recommended range or gain curve, translate the notation used by the source.

4. Lm Sets the Lower Characteristic Resonant Frequency

The lower characteristic resonance is:

fm=12π(Lr+Lm)Crf_m=\frac{1}{2\pi\sqrt{(L_r+L_m)C_r}}

Normalized to the series resonant frequency:

Fm=fmfr=11+LnF_m=\frac{f_m}{f_r}=\frac{1}{\sqrt{1+L_n}}

Increasing Lm increases Ln and pushes fm farther below fr. Decreasing Lm pulls the lower characteristic frequency upward toward series resonance.

LLC characteristic-frequency comparison showing how Ln values of 3.5, 5, and 8 move the lower characteristic frequency fm while the series resonant frequency fr remains fixed at Fn equals 1.

Figure 7-1. LLC characteristic-frequency comparison showing how changing Lm/Ln moves the lower characteristic resonance fm relative to the fixed series resonance fr.

5. Lm Shapes the Available Gain

Lower Lm generally increases the available LLC boost gain below resonance, while higher Lm reduces it. This is one reason a wide input-voltage range often drives the designer toward a lower Ln.

Lm / Ln DirectionGain BehaviorSystem Consequence
Lower Lm / lower LnMore available boost gainCan reduce required frequency excursion but increases magnetizing/circulating current.
Higher Lm / higher LnLess available boost gainCan improve conduction efficiency but may require a narrower input range, different turns ratio, or larger frequency span.

ENGINEERING CAUTION

Do Not Select Lm from Gain Alone

A low Lm can make the gain curve look excellent while producing unacceptable primary RMS current and transformer heating.

Every gain benefit must be evaluated against current and loss.

6. Magnetizing Current Follows the Inductor Voltage Law

Magnetizing current follows the basic inductor law:

dimdt=vPLm\frac{di_m}{dt}=\frac{v_P}{L_m}

Over a finite interval:

Δim=1Lm∫t1t2vP(t)dt\Delta i_m=\frac{1}{L_m}\int_{t_1}^{t_2}v_P(t)\,dt

For the same applied volt-seconds, magnetizing-current excursion is inversely proportional to Lm. This direct relationship is the physical reason lower Lm creates more circulating current.

7. A Useful Near-Resonance Magnetizing-Current Estimate

For a common LLC operating condition near resonance, with a roughly square magnetizing voltage associated with the reflected secondary voltage, a useful first-pass peak magnetizing-current estimate is:

Im,pk≈nVS,eff4LmfsI_{m,pk}\approx\frac{nV_{S,eff}}{4L_mf_s}

For an approximately symmetric triangular magnetizing waveform:

Im,pp≈2Im,pkI_{m,pp}\approx2I_{m,pk}

and a first-pass RMS estimate is:

Im,rms≈Im,pk3I_{m,rms}\approx\frac{I_{m,pk}}{\sqrt{3}}

ENGINEERING CAUTION

The Near-Resonance Current Formula Is Not a Universal LLC Waveform Equation

It assumes a specific first-pass operating condition and approximately triangular magnetizing current.

At boost operation, high frequency, burst, startup, or with significant parasitics, use the actual time-domain magnetizing voltage/current waveform.

8. Lower Lm Increases Circulating Current and Conduction Loss

Magnetizing current circulates on the primary side even when it does not represent useful transferred load current. That current contributes to MOSFET conduction loss, primary winding loss, resonant-component current, and thermal stress.

A generic first-pass circulating-loss expression is:

Pcirc≈Icirc,rms2ReqP_{circ}\approx I_{circ,rms}^2R_{eq}

Because current enters as a square, a modest increase in circulating RMS current can produce a large increase in conduction loss. Infineon LLC guidance explicitly highlights this tradeoff: lower magnetizing inductance increases gain but also increases primary RMS current and conduction loss.

9. Lower Lm Also Provides More ZVS-Supporting Current

The same magnetizing current that creates conduction loss can help commutate the primary switches during dead time. Lower Lm therefore tends to increase the available current and energy for ZVS.

Peak energy in the magnetizing inductance is:

Em,pk=12LmIm,pk2E_{m,pk}=\frac{1}{2}L_mI_{m,pk}^2

Substituting the near-resonance current estimate gives:

Em,pk≈n2VS,eff232Lmfs2E_{m,pk}\approx\frac{n^2V_{S,eff}^2}{32L_mf_s^2}

Under those assumptions, available magnetizing energy decreases as Lm increases. This is why excessively high Lm can weaken light-load ZVS even while it reduces circulating loss.

10. ZVS Should Be Checked with Charge or Energy, Not Current Alone

Actual ZVS depends on charging and discharging nonlinear switch-node capacitances during dead time. A useful current/charge requirement is:

|Icomm|≳Qreqtd|I_{comm}|\gtrsim\frac{Q_{req}}{t_d}

An equivalent energy statement is:

Ecomm,avail≥Eoss,reqE_{comm,avail}\ge E_{oss,req}

The available commutation energy can include both resonant and magnetizing contributions. At light load, magnetizing current often becomes especially important because transferred load current is small.

ENGINEERING CAUTION

Do Not Use Lm Alone to Declare ZVS

Device Qoss/Eoss is nonlinear with voltage, dead time is finite, resonant current contributes, and parasitic capacitances exist outside the MOSFET.

Use charge/energy analysis plus switching waveforms to verify ZVS at the worst relevant line/load/frequency corners.

LLC magnetizing inductance tradeoff showing circulating current decreasing as Lm increases while ZVS-supporting commutation energy also falls, with a practical design region between the extremes.

Figure 7-2. Magnetizing-inductance tradeoff between circulating current and ZVS-supporting commutation energy.

11. High Lm Can Improve Efficiency but Shrink the Gain Window

Increasing Lm can reduce magnetizing and circulating current, which improves conduction efficiency. Infineon high-power LLC guidance uses larger magnetizing-inductance ratios as one lever for reducing circulating primary current.

The cost is reduced available gain and reduced commutation energy. If the converter then needs a lower minimum switching frequency to reach low-line gain, the design can approach an undesirable operating boundary.

Higher Lm BenefitHigher Lm Cost
Lower primary magnetizing RMS currentReduced boost-gain capability
Lower circulating/conduction lossPotentially larger required frequency span
Potentially lower transformer copper lossWeaker light-load ZVS current/energy
Lower resonant current contribution from magnetizing branchMore sensitivity to device Qoss and dead-time choice

12. Light Load Often Sets the Maximum Useful Lm

At light load, transferred current falls while magnetizing current remains. This makes light load one of the most important conditions for deciding how high Lm can be.

  • Minimum load at which continuous switching is required.
  • Maximum switching frequency at light load.
  • Minimum magnetizing current available during dead time.
  • MOSFET Qoss / Eoss at actual bus voltage and temperature.
  • Controller dead-time range.
  • Burst-entry and burst-exit behavior.

SOLIDMAG ENGINEERING INSIGHT

The Maximum Useful Lm Is Often a ZVS Limit, Not a Gain Limit

A design may still regulate with a high Lm but lose efficient primary commutation at light load.

Use the minimum required ZVS load point as an explicit Lm design input.

13. Full Load Often Sets the Cost of Choosing Lm Too Low

At full load, the problem reverses. Resonant/load current is large, so ZVS may be easy, but a low Lm adds magnetizing current on top of already high transferred current.

  • Primary winding RMS current.
  • MOSFET conduction current.
  • Resonant inductor and capacitor RMS current.
  • Transformer copper loss.
  • Thermal rise.
  • Efficiency at nominal and maximum power.

The minimum useful Lm is therefore often constrained by current and loss rather than gain alone.

14. Lm Tolerance Must Be Treated as a Converter Tolerance

A production Lm target must include tolerance. If δm is the allowed fractional tolerance around nominal:

Lm,min⁡=Lm,nom(1−δm)L_{m,\min}=L_{m,nom}(1-\delta_m)
Lm,max⁡=Lm,nom(1+δm)L_{m,\max}=L_{m,nom}(1+\delta_m)
Tolerance CornerConverter Effect
Lm minimumHigher magnetizing current, circulating loss, and commutation energy; altered gain.
Lm nominalIntended gain/current/ZVS balance.
Lm maximumLower current/loss but reduced gain and light-load ZVS support.

ENGINEERING CAUTION

Check Both Ends of the Lm Tolerance

Designers sometimes treat only low Lm as dangerous because current rises.

For LLC, high Lm can also be a failure corner if gain or ZVS margin becomes insufficient.

EARLY ENGINEERING ACCESS

Get Your First Custom Magnetic Design for $49

Need a custom inductor, flyback transformer, or currently supported LLC/resonant transformer design for a real project? SolidMagnetics Early Engineering Access gives you a lower-cost way to evaluate the platform while it continues to expand.

STANDARD SINGLE DESIGN PRICE: $249   •   EARLY ACCESS PRICE: $49

Use coupon code EARLYACCESS. Your supported design package can include:

  • Candidate magnetic design output and recommended design direction
  • SolidWorks Reference CAD and STEP export where supported
  • Engineering drawings, BOM, winding, and design data where supported
  • A practical starting point for component matching, simulation, prototyping, or further development

Offer details: Limited to the first 10 qualified paid projects. One discounted project per customer. Expires February 12, 2027, or when all 10 uses are claimed, whichever comes first.

SolidMagnetics-generated designs are engineering starting points intended to accelerate development. Final component selection, manufacturability, tolerances, winding construction, insulation, creepage and clearance, thermal performance, regulatory requirements, and production suitability must be verified for the intended application.

15. Temperature and Measurement Conditions Change Realized Lm

The Lm value measured on an LCR meter is meaningful only when the measurement condition is defined. Core permeability, gap, frequency, test amplitude, temperature, assembly pressure, and winding connections can change the measured result.

  • Test frequency.
  • Test amplitude / flux level.
  • Primary winding terminals used.
  • Secondary windings open or in a defined state.
  • Reference temperature.
  • Core assembly / clamp condition.
  • Whether the specification is small-signal inductance or operating large-signal behavior.

SOLIDMAG ENGINEERING INSIGHT

The Production Test Must Measure the Parameter the Converter Actually Needs

A precise small-signal room-temperature Lm measurement is not enough if the operating inductance shifts materially at bias, temperature, or frequency.

Define a production test that is repeatable, then validate its correlation to converter behavior.

16. Lm Must Be Realized with Turns, Core, and Gap

The converter specifies Lm, but the transformer realizes it through primary turns, magnetic reluctance, core geometry, and any intentional gap. A common AL relationship is:

Lm=ALNP2L_m=A_LN_P^2

The required AL for a chosen primary turn count is:

AL,req=LmNP2A_{L,req}=\frac{L_m}{N_P^2}

Chapter 9 will determine whether the Chapter 6 turns candidate and Chapter 7 Lm target can be realized with acceptable flux, core loss, gap, window fill, and saturation margin.

17. Gap-Dominated Magnetizing Inductance and AL

When an intentional air gap dominates magnetic reluctance, a useful first-order relationship is:

L≈μ0N2AegeffL\approx\frac{\mu_0N^2A_e}{g_{eff}}

This form shows why Lm, turns, core area, and effective gap cannot be selected independently. Increasing gap lowers Lm for the same turns; increasing turns raises Lm but also changes flux per volt, copper length, winding capacitance, and leakage.

For a simple AL-based relation, first-order variation can be expressed as:

ΔLmLm≈ΔALAL+2ΔNPNP\frac{\Delta L_m}{L_m}\approx\frac{\Delta A_L}{A_L}+2\frac{\Delta N_P}{N_P}

ENGINEERING CAUTION

Gap Fringing and Nonlinear Core Behavior Require More Than the Simple Gap Formula

Large gaps create fringing fields that increase local winding loss and alter effective magnetic geometry.

Use actual core/gap data or field analysis when the simple reluctance approximation is no longer adequate.

18. Lm and Leakage Cannot Be Designed Independently in an Integrated Transformer

If transformer leakage supplies part or all of Lr, the same winding geometry that affects leakage can also affect Lm, coupling, interwinding capacitance, and AC resistance.

Increasing primary-secondary separation may increase leakage, but it also changes window utilization and capacitance. Interleaving may reduce leakage but move the design away from an integrated-Lr target.

Chapter 8 treats this coupled Lm/Lr physical design problem directly.

SOLIDMAG ENGINEERING INSIGHT

An Integrated LLC Transformer Has Two Inductance Targets

Lm and leakage-derived Lr are not independent checkboxes.

The winding/core structure must realize both simultaneously while still meeting capacitance, loss, isolation, and manufacturing constraints.

19. Worked Example — Ln = 5 for the 500 W / 48 V LLC

WORKED DESIGN EXAMPLE

Ln = 5 for the 500 W / 48 V LLC

Continue the Chapter 4 tank and Chapter 6 turns ratio: Lr = 31.7 µH, Cr = 35.5 nF, fr = 150 kHz, n = 33/8 = 4.125, and effective secondary voltage VS,eff = 48.5 V.

The Chapter 4 nominal Ln = 5 therefore sets the first-pass magnetizing-inductance target.

Lm=5(31.7 μH)=158.5 μHL_m=5(31.7\ \mu\mathrm{H})=158.5\ \mu\mathrm{H}

Near resonance at 150 kHz, the first-pass peak magnetizing current is:

Im,pk≈4.125(48.5)4(158.5 μH)(150000)≈2.10 AI_{m,pk}\approx\frac{4.125(48.5)}{4(158.5\ \mu\mathrm{H})(150\,000)}\approx2.10\ \mathrm{A}

The corresponding triangular-wave RMS estimate is:

Im,rms≈2.103≈1.21 AI_{m,rms}\approx\frac{2.10}{\sqrt{3}}\approx1.21\ \mathrm{A}

The associated peak magnetizing energy is approximately:

Em,pk≈12(158.5 μH)(2.10)2≈0.350 mJE_{m,pk}\approx\frac{1}{2}(158.5\ \mu\mathrm{H})(2.10)^2\approx0.350\ \mathrm{mJ}

ENGINEERING CAUTION

Do Not Use 0.350 mJ as the Final ZVS Energy Claim

This is magnetizing energy under a simplified near-resonance estimate. The actual commutation event also depends on resonant current, switching phase, nonlinear MOSFET output charge, parasitic capacitance, and dead time.

Use the value as a comparative Lm metric, then verify ZVS with the actual switching model.

20. Compare Ln = 3.5, 5, and 8

Compare three candidate inductance ratios while holding Lr = 31.7 µH, n = 4.125, VS,eff = 48.5 V, and fs = 150 kHz for the current estimate:

Lm=3.5(31.7 μH)≈111.0 μHL_m=3.5(31.7\ \mu\mathrm{H})\approx111.0\ \mu\mathrm{H}
Lm=8(31.7 μH)≈253.6 μHL_m=8(31.7\ \mu\mathrm{H})\approx253.6\ \mu\mathrm{H}
LnLmIm,pk @ 150 kHzIm,rmsEm,pkFn for M≈1.053*fs for fr=150 kHz*
3.5110.9 µH3.01 A1.74 A0.501 mJ0.917137 kHz
5158.5 µH2.10 A1.21 A0.351 mJ0.878132 kHz
8253.6 µH1.31 A0.76 A0.219 mJ0.757114 kHz

*The Fn/fs values use the Chapter 4 FHA gain equation with Q = 0.5 and show the approximate low-line frequency needed for M ≈ 1.053. They are illustrative; changing n changes Q and all final operating corners must be recalculated.

Comparison of LLC Ln candidates 3.5, 5, and 8 showing relative magnetizing inductance, peak magnetizing current, magnetizing energy, low-line gain, normalized frequency, and ZVS margin.

Figure 7-3. Comparison of Ln = 3.5, 5, and 8 showing magnetizing current, magnetizing energy, and low-line gain/frequency behavior.

SOLIDMAG ENGINEERING INSIGHT

The Numerical Tradeoff Is Visible Immediately

The low-Lm candidate produces substantially more magnetizing current and commutation energy, but that same current becomes conduction and winding loss.

The high-Lm candidate reduces circulating current but demands more from the gain/frequency/ZVS design.

21. Recalculate Gain and Frequency for Each Lm Candidate

Changing Lm changes Ln, so the Chapter 4 gain curve must be regenerated for each candidate. Do not compare magnetizing-current values while leaving the electrical gain model fixed.

  • Recalculate Ln = Lm/Lr.
  • Recalculate fm and normalized Fm.
  • Regenerate full-load and light-load gain curves.
  • Recalculate the frequency required for Mreq,max and Mreq,min.
  • Recheck the inductive/capacitive boundary.
  • Recalculate primary resonant and magnetizing RMS current.
  • Recheck ZVS charge/energy margin at light load.
  • Recheck full-load conduction loss and transformer temperature.
LLC gain curves for Ln values of 3.5, 5, and 8 at common Q showing differences in peak gain, switching-frequency range, magnetizing current, low-line required gain, and nominal resonance at Fn equals 1.

Figure 7-4. LLC gain curves for several magnetizing-inductance ratios showing the tradeoff between maximum gain, switching-frequency range, and magnetizing current.

22. Define the Production Lm Specification

Once the acceptable Lm range is known, convert it into a measurable transformer specification rather than only a nominal design value.

Specification ItemRequired Definition
Lm nominalTarget value at defined measurement condition.
Lm minimumLowest production value allowed by current/loss limits.
Lm maximumHighest production value allowed by gain/ZVS limits.
Test frequencyDefined LCR test frequency.
Test amplitudeDefined voltage/current or flux level.
Winding stateSecondary open and other windings in defined state unless another method is specified.
TemperatureReference room temperature or defined production-test range.
Core assemblyClamping, adhesive, spacer/gap, and assembly state.

Chapter 14 will combine this Lm specification with leakage, DCR, ratio, dielectric, and dimensional production tests.

  1. Import Lr, Cr, fr, gain window, n, Q, and current requirements from Chapters 4–6.
  2. Choose an initial Ln / Lm candidate.
  3. Generate gain curves and verify Mreq,min / Mreq,max.
  4. Calculate near-resonance magnetizing current.
  5. Calculate full-load circulating-current and conduction-loss impact.
  6. Calculate light-load commutation-current / ZVS requirement.
  7. Check minimum and maximum switching-frequency requirements.
  8. Apply Lm tolerance and repeat gain/current/ZVS checks.
  9. Choose a provisional NP and calculate required AL.
  10. Verify that core/gap candidates can realize Lm without unacceptable flux or loss.
  11. If leakage supplies Lr, iterate winding geometry so Lm and Lr are achieved together.
  12. Define the production Lm measurement condition and acceptance range.
  13. Retain multiple candidates until Chapters 8–12 close leakage, core, winding, parasitic, and thermal constraints.
LLC magnetizing-inductance design workflow showing Ln and Lm selection, gain and current checks, ZVS margin, tolerance analysis, AL and core realization, winding geometry, production testing, and iterative feedback.

Figure 7-5. Magnetizing-inductance design workflow from Ln/Lm selection through gain, current, ZVS, tolerance, AL/core realization, integrated leakage, production test, and iteration.

24. Design Handoff to Controlled Leakage and Resonant Inductance

At the end of Chapter 7, the design should hand Chapter 8 a defined magnetizing-inductance range plus the resonant-inductance target and architecture assumptions.

  • Selected Lm nominal, minimum, and maximum.
  • Selected Ln and the equivalent alternative m ratio if needed for supplier/controller documentation.
  • Magnetizing peak and RMS current envelope.
  • Light-load ZVS / commutation-current requirement.
  • Full-load circulating-current / loss constraint.
  • Target primary turns or provisional NP range for AL/core evaluation.
  • Measurement condition for Lm.
  • Target total Lr and whether transformer leakage is external, integrated, or hybrid.

Chapter 8 now determines how much resonant inductance should be created by controlled transformer leakage and how to measure it repeatably.

25. Chapter 7 Engineering Checklist

  • Ln = Lm/Lr convention is used consistently.
  • Alternative m notation has been translated correctly where referenced.
  • fm and Fm have been recalculated for the selected Lm.
  • Required gain is achieved across line/load with the selected Lm.
  • Minimum and maximum switching frequencies remain practical.
  • Near-resonance magnetizing current has been estimated.
  • Full-load primary RMS/conduction loss has been checked.
  • Light-load ZVS current/energy requirement has been checked.
  • MOSFET Qoss/Eoss and dead time are included in the final ZVS verification.
  • Lm minimum and maximum tolerance corners have both been checked.
  • Temperature and test conditions for Lm are defined.
  • Required AL is compatible with provisional NP and core candidates.
  • Gap/fringing implications are recognized.
  • If leakage supplies Lr, Lm and leakage are being designed together.
  • Production Lm specification includes value, tolerance, frequency, amplitude, winding state, and temperature.

CHAPTER TAKEAWAY

The Best Lm Is a Balanced System Value

Lower Lm buys gain and ZVS-supporting current at the cost of circulating loss. Higher Lm buys lower current and better conduction efficiency at the cost of gain and commutation margin.

The chosen Lm should sit between those failure modes with enough tolerance for production variation.

26. Conclusion — Lm Is a Tradeoff Between Gain, Current, and ZVS

Magnetizing inductance is one of the defining transformer parameters in an LLC converter. It sets the inductance ratio, moves the lower characteristic resonance, shapes gain, determines magnetizing-current slope, and changes both conduction loss and ZVS-supporting commutation energy.

The design objective is not maximum Lm or minimum Lm. It is an Lm range that provides the required gain and light-load ZVS while keeping full-load circulating current, copper loss, semiconductor conduction loss, and transformer temperature acceptable.

With Lm now bounded, Chapter 8 can solve the other inductive requirement that may be intentionally built into the transformer: resonant inductance through controlled leakage.

Technical References for This Chapter

The Lm tradeoffs described here are consistent with current manufacturer LLC guidance: lower magnetizing inductance increases gain and primary circulating current, while smaller inductance ratios can extend ZVS range at the cost of higher RMS current. Final designs should use the selected controller documentation, MOSFET Qoss/Eoss data, magnetic material data, switching simulation, and prototype measurements.

RESONANT CONVERTER TRANSFORMER DESIGN

Ready to Design a Resonant Converter Transformer?

Enter your resonant-converter requirements and begin a SolidMagnetics transformer design workflow built around the electrical, magnetic, winding, thermal, mechanical, and manufacturing constraints that shape a practical LLC or related resonant transformer.

Use the design interface to define the converter operating range, transformer requirements, resonant and magnetizing inductance targets, winding priorities, isolation needs, thermal limits, physical constraints, and optimization goals.

Return to the Ultimate Guide to Resonant Converter Transformer Design

READY TO APPLY THIS?

Turn Your Requirements Into a Real Magnetic Design

If you are working on a real inductor, flyback transformer, or supported LLC/resonant transformer project, SolidMagnetics can help you move faster from electrical requirements to calculated magnetic geometry and engineering output.

FOUNDING EARLY ENGINEERING ACCESS: $249   →   $49

Use coupon code EARLYACCESS for the Single Design package. This offer is intended for engineers who want to evaluate the current SolidMagnetics workflow and provide practical feedback that helps improve the platform.

What the Current Package Can Include

  • Requirements and feasibility review
  • Candidate design comparison and recommended design
  • Electrical, magnetic, loss, and thermal calculations
  • SolidWorks Reference CAD and STEP files where supported
  • Drawings, BOM, winding, and engineering data where supported
  • A basis for comparing custom geometry with commercial core and bobbin options

Early Access Offer Details

  • Single Design standard price: $249
  • Early Engineering Access price: $49
  • Coupon code: EARLYACCESS
  • Limited to 10 total qualified paid projects
  • One discounted project per customer
  • Expires February 12, 2027, or when all 10 uses are claimed
  • Brief post-delivery feedback is requested

The standard package provides a Reference CAD representation of the generated design rather than the complete underlying SolidMagnetics parametric automation structure. Fully parametric engineering CAD may be available separately for qualifying advanced or Enterprise projects.

Early Access calculations, CAD, drawings, and related deliverables are intended to accelerate engineering evaluation and prototype development. Final mechanical, electrical, thermal, insulation, regulatory, manufacturing, and production validation remains the responsibility of the customer and their engineering team.

ABOUT THE AUTHOR

Stan Gibson

Electrical Engineer & Founder, SolidMagnetics

Stan Gibson is an electrical engineer and founder of SolidMagnetics, an engineering platform focused on magnetic-component design automation. His work includes power electronics, inductor and transformer design, magnetic-core selection, winding design, thermal analysis, and manufacturable CAD development. Through SolidMagnetics, he develops technical guides, calculators, and automated design tools intended to help engineers move from electrical requirements to practical magnetic-component designs.

View Full Author Profile