Chapter 9: Core Selection, Turns, Flux Density, and Saturation Margin

Chapters 6–8 established the transformer ratio, magnetizing inductance, and resonant/leakage-inductance architecture. Chapter 9 now turns those electrical targets into a magnetic structure by selecting a core family and ferrite material, determining the absolute primary and secondary turns, calculating flux swing, checking core loss and saturation margin, and choosing the AL / gap needed to realize the required Lm.

The key idea is that turns are not chosen from Lm alone. Primary turns are first constrained by volt-seconds, core area, allowable flux density, frequency, core loss, and transient margin. Only then can the core AL and gap be adjusted to realize the required magnetizing inductance. The final candidate must also leave enough winding window for Chapter 10 and preserve the leakage/capacitance architecture from Chapter 8.

In This Chapter — Click to Expand

Table of Contents

DESIGN ASSUMPTION

Flux Calculations Use the Actual Transformer Voltage

Faraday’s law applies to the voltage across the transformer primary winding, not automatically to the half-bridge switch-node voltage.

For the worked example near normal secondary conduction, VP,flat is approximated from the reflected effective secondary voltage n·VS,eff. When a square/flat-topped approximation is used, it is identified explicitly.

Final flux calculations should integrate the actual primary winding voltage from switching simulation or measurement over the complete operating envelope.

1. Core Selection Begins After the Electrical Targets Are Known

A core should be selected only after turns ratio, Lm, Lr architecture, frequency range, current envelope, isolation, thermal limits, and mechanical envelope are known. Otherwise the design process becomes a sequence of arbitrary part choices that later force the converter to adapt to the magnetics.

The core is feasible only if it provides enough effective area for the required volt-seconds, enough window area for the winding and insulation, acceptable core loss over temperature, a realizable Lm/gap target, and a geometry compatible with the controlled-leakage strategy.

SOLIDMAG ENGINEERING INSIGHT

The Core Is a Candidate to Be Verified, Not a Starting Assumption

Automated magnetic design is stronger when it can screen several core/material combinations against the same electrical requirements.

Core selection should follow the requirements—not define them.

2. Core Material, Shape, and Size Solve Different Problems

DecisionWhat It Primarily Controls
MaterialCore loss vs. frequency/flux/temperature, permeability, saturation behavior.
ShapeWindow geometry, winding breadth, leakage/capacitance opportunity, cooling surface, PCB footprint.
SizeEffective area Ae, window area Aw, core volume Ve, thermal capacity, available turns/winding space.
Gap / ALMagnetizing inductance for the selected NP and core.

Power ferrite is the normal starting point for high-frequency LLC transformers. TI transformer-design material and current LLC support guidance both point designers toward ferrite core families selected for the intended switching-frequency range.

3. Know the Core Parameters Before Calculating Turns

Core ParameterMeaning in This Chapter
AeEffective magnetic cross-sectional area; central to volt-second / flux calculations.
AwAvailable winding-window area before insulation and manufacturing allowances.
VeEffective magnetic volume; used with vendor loss density to estimate total core loss.
leEffective magnetic path length; relevant to reluctance/permeability calculations.
ALInductance factor for the assembled/gapped core, typically inductance per turns squared.
MLTMean length per turn; important to copper length and winding loss.
Ap = AeAwArea product; useful only as a preliminary core-size screening metric.

4. Faraday’s Law Is the Foundation of the Turns Calculation

Faraday’s law for the transformer primary is:

vP=NPAedBdtv_P=N_PA_e\frac{dB}{dt}

The flux-density change over any interval is:

ΔB=1NPAe∫t1t2vP(t)dt\Delta B=\frac{1}{N_PA_e}\int_{t_1}^{t_2}v_P(t)\,dt

SOLIDMAG ENGINEERING INSIGHT

Volt-Seconds Determine Flux; Inductance Does Not Replace Faraday’s Law

Lm controls magnetizing-current slope, while primary volt-seconds and turns/core area determine flux swing.

Both must be satisfied simultaneously.

5. Use the Actual Transformer Primary-Voltage Waveform

In an LLC converter, the bridge drives the resonant tank, so not all bridge voltage necessarily appears across the transformer primary at every instant. The transformer voltage can be clamped by the reflected secondary during conduction and shaped by resonance during commutation intervals.

Infineon LLC guidance calculates primary turns from the actual transformer primary voltage, using the reflected output voltage and half switching-cycle duration. That is the correct principle to preserve even when the waveform is obtained from simulation rather than a simple closed-form approximation.

VP,flat≈nVS,effV_{P,flat}\approx nV_{S,eff}

ENGINEERING CAUTION

Do Not Blindly Substitute Vin/2 for the Transformer Primary Voltage

Vin/2 is the half-bridge drive amplitude at the tank input. The transformer primary waveform depends on Lr, Cr, Lm, load, frequency, rectification state, and resonant transitions.

Use the actual winding waveform for the final flux calculation.

6. Flux Balance and DC Bias Must Be Checked Separately

In periodic steady state, the net volt-seconds applied to the transformer over a complete cycle should be approximately zero:

∮vP(t)dt≈0\oint v_P(t)\,dt\approx0

If positive and negative volt-seconds do not balance, flux can walk away from the intended center point. The series resonant capacitor helps block DC, but startup, asymmetric gate timing, controller faults, capacitor precharge, and transient operating states should still be checked.

7. Convert Volt-Seconds into Peak-to-Peak Flux Swing

If the primary winding sees approximately ±VP,flat for one half-cycle each, the peak-to-peak flux-density swing is:

ΔBpp≈VP,flat2fsNPAe\Delta B_{pp}\approx\frac{V_{P,flat}}{2f_sN_PA_e}

This is the flux excursion from the negative extreme to the positive extreme under a balanced, approximately flat-topped winding-voltage assumption.

8. Relate Flux Swing to Peak Flux Density

Peak flux density should include any offset of the flux center:

Bpk=|Bcenter|+ΔBpp2B_{pk}=|B_{center}|+\frac{\Delta B_{pp}}{2}

If the waveform is well balanced and Bcenter ≈ 0:

Bpk≈VP,flat4fsNPAeB_{pk}\approx\frac{V_{P,flat}}{4f_sN_PA_e}
Transformer primary voltage and flux-density waveform for a balanced LLC interval showing voltage pulse polarity, flux-density ramp, centered peak flux, and peak-to-peak flux swing Delta Bpp.

Figure 9-1. Transformer primary voltage, flux-density ramp, peak-to-peak flux swing, and centered peak flux density for a balanced LLC operating interval.

9. Half-Bridge and Full-Bridge Shortcuts Require Clear Assumptions

For a half bridge near a condition where the transformer primary magnitude is approximately Vin/2, the first-pass shortcut is:

VP,flat≈KBVinV_{P,flat}\approx K_BV_{in}
Primary BridgeKB in the Shortcut
Half bridge0.5
Full bridge1.0

Use this only when the actual primary winding waveform supports the approximation. The general volt-second integral remains authoritative.

10. The Worst Flux Corner Is the Worst V/f Corner

Flux is proportional to primary volt-seconds per turn. Therefore the worst steady-state flux corner is the operating point with the largest VP,flat/fs ratio—not necessarily the highest input voltage.

CornerPotential Flux Effect
Low line / boostLower switching frequency can increase volt-seconds even though bus voltage is lower.
Nominal / resonanceOften a major loss point because power is high and frequency is near fr.
High line / buckHigher frequency can reduce volt-seconds despite higher bus voltage.
Startup / faultCan produce unusual pulse patterns or asymmetry not present in steady state.

ENGINEERING CAUTION

Do Not Use Vin,max and fs,min If the Controller Can Never Produce Them Together

A conservative worst case should still be physically possible.

Build the flux corner from the actual gain/frequency operating map developed in Chapters 3–7.

11. Solve Minimum Turns or Minimum Core Area from the Flux Limit

For the balanced flat-topped approximation, minimum primary turns are:

NP≥VP,flat4fsAeBpk,allowN_P\ge\frac{V_{P,flat}}{4f_sA_eB_{pk,allow}}

For a provisional NP, minimum effective core area is:

Ae≥VP,flat4fsNPBpk,allowA_e\ge\frac{V_{P,flat}}{4f_sN_PB_{pk,allow}}

These equations allow the core search and turns search to be coupled: a larger Ae can reduce required turns; more turns can allow a smaller Ae but consume more copper/window area and raise winding resistance/capacitance.

12. Saturation Is Not Usually the Only Flux Limit

The allowable operating flux should be the most restrictive of several limits:

Ballow=min⁡(Bloss,Bsat,derated,Btransient)B_{allow}=\min(B_{loss},B_{sat,derated},B_{transient})
  • Core-loss / thermal limit at the actual switching frequency and temperature.
  • Derated saturation limit at the hottest credible core temperature.
  • Transient / startup / fault flux limit.
  • Any additional reliability or acoustic constraint.

At high switching frequency, ferrite designs are often core-loss limited well below the material’s saturation flux density. TI transformer-design guidance explicitly recommends checking loss after the initial flux-density selection because the loss limit can be more restrictive than saturation.

13. Define Saturation Margin at the Hot Worst-Case Condition

Use the minimum credible hot saturation flux density from the material vendor and the worst-case peak operating flux. A useful margin metric is:

MB=Bsat,min−Bpk,wcBsat,min×100%M_B=\frac{B_{sat,min}-B_{pk,wc}}{B_{sat,min}}\times100\%

The required margin depends on controller behavior, startup, tolerances, material data, temperature, reliability target, and how rapidly inductance collapses near saturation.

14. Core Loss Usually Sets a Lower Practical Flux Density

Core loss can dominate before the core approaches saturation. Increasing turns lowers flux and often lowers core loss, but also increases copper length and can force smaller conductor cross section or more winding layers.

Infineon LLC guidance shows this directly: increasing transformer turns can substantially reduce core excitation loss while raising winding resistance. Core turns are therefore an efficiency optimization variable, not simply the minimum value that avoids saturation.

SOLIDMAG ENGINEERING INSIGHT

Minimum Turns Is Usually Not Optimum Turns

The minimum-turn calculation defines a feasibility floor.

The efficient design often uses more turns until the reduction in core loss is no longer worth the increase in copper and winding loss.

15. Use Manufacturer Loss Data at Frequency, Flux, and Temperature

Use the selected material’s loss density as a function of actual frequency, flux waveform/amplitude, and temperature. If Pv is the vendor loss density and Ve is effective core volume:

Pcore=Pv(f,B^,T)VeP_{core}=P_v(f,\hat B,T)V_e

For a vendor-supported sinusoidal Steinmetz region, a simplified empirical form may be written:

Pv≈ksfαBβP_v\approx k_sf^\alpha B^\beta

ENGINEERING CAUTION

Use Steinmetz Coefficients Only Within Their Valid Conditions

Vendor Steinmetz coefficients may assume sinusoidal excitation and a limited frequency, flux, and temperature range.

For non-sinusoidal LLC transformer flux, use manufacturer waveform guidance, generalized/iGSE methods where appropriate, or measured loss correlation.

16. Choose the Ferrite Material for the Actual Frequency Window

Ferrite material selection should cover the entire frequency and temperature window, not only nominal fr. Current TDK power-ferrite catalogs separate materials by useful frequency range and provide loss, permeability, saturation, and performance-factor data.

  • Power-loss density at minimum, nominal, and maximum switching frequency.
  • Loss versus temperature at the expected flux density.
  • Saturation flux density versus temperature.
  • Initial / amplitude permeability where relevant to the Lm/gap design.
  • Availability in the required core shape and size.
  • Supplier lifecycle and production availability.

TDK’s current Magnetic Design Tool can plot power loss versus temperature, frequency, and flux density for current materials and can calculate AL versus air gap for supported core forms.

17. Core Shape Changes Winding Loss, Leakage, Capacitance, and Cooling

Core Shape CharacteristicDesign Effect
Wide winding windowFewer winding layers and potentially lower proximity loss; fixed creepage margins consume a smaller fraction of width.
Large center-post / AeMore volt-second capability per turn and lower flux for a given NP.
Large window height / radial buildMore space for insulation and multiple winding sections; can change leakage/capacitance.
Planar geometryLow profile and repeatable winding geometry; high coupling can make large integrated leakage harder without deliberate structure.
PQ / compact power shapeGood volume utilization and common in high-density power designs; thermal and winding breadth still must be checked.
ETD/EER-style geometryCan provide broad winding width and practical bobbins; footprint/height and leakage strategy vary by size.

TI transformer-design guidance emphasizes winding-window geometry because a wider winding breadth can reduce the number of layers and AC resistance. In an integrated LLC transformer, however, Chapter 8 may intentionally require reduced overlap or sectioning to create leakage.

EARLY ENGINEERING ACCESS

Get Your First Custom Magnetic Design for $49

Need a custom inductor, flyback transformer, or currently supported LLC/resonant transformer design for a real project? SolidMagnetics Early Engineering Access gives you a lower-cost way to evaluate the platform while it continues to expand.

STANDARD SINGLE DESIGN PRICE: $249   •   EARLY ACCESS PRICE: $49

Use coupon code EARLYACCESS. Your supported design package can include:

  • Candidate magnetic design output and recommended design direction
  • SolidWorks Reference CAD and STEP export where supported
  • Engineering drawings, BOM, winding, and design data where supported
  • A practical starting point for component matching, simulation, prototyping, or further development

Offer details: Limited to the first 10 qualified paid projects. One discounted project per customer. Expires February 12, 2027, or when all 10 uses are claimed, whichever comes first.

SolidMagnetics-generated designs are engineering starting points intended to accelerate development. Final component selection, manufacturability, tolerances, winding construction, insulation, creepage and clearance, thermal performance, regulatory requirements, and production suitability must be verified for the intended application.

18. Area Product Is a Screening Tool, Not a Final Design Rule

The core area product is:

Ap=AeAwA_p=A_eA_w

Area product is useful for quickly rejecting cores that are obviously too small, but it does not include the full LLC winding, leakage, capacitance, insulation, core-loss, and thermal problem.

ENGINEERING CAUTION

Do Not Release an LLC Transformer from Area Product Alone

A core can have adequate Ap and still fail because its window shape creates too many layers, its leakage target is unreachable, or its material loss is excessive at the required frequency.

Use area product as a filter, then run the full design.

19. Reserve Enough Window Area for the Real Winding

Before committing to a core, reserve enough window area for conductor, insulation, margins, shields, section gaps, and manufacturing variation. A simple fill metric is:

Kfill=AusedAw,usableK_{fill}=\frac{A_{used}}{A_{w,usable}}

Chapter 10 will calculate the actual conductor area and AC-loss-aware winding structure. Chapter 9 should only reject cores whose usable window is clearly incompatible with the required windings and insulation.

20. Realize Lm with AL, Turns, and Magnetic Reluctance

Once primary turns are chosen from volt-seconds/core-loss considerations, the core must be adjusted to realize the Chapter 7 magnetizing inductance. The AL relationship is:

Lm=ALNP2L_m=A_LN_P^2

Therefore:

AL,req=LmNP2A_{L,req}=\frac{L_m}{N_P^2}

The equivalent magnetic reluctance required by the primary is:

Rm=NP2LmR_m=\frac{N_P^2}{L_m}

SOLIDMAG ENGINEERING INSIGHT

Turns Are Chosen for Flux; Gap / AL Is Adjusted for Lm

Trying to choose NP from Lm = ALN² using an ungapped catalog AL can produce far too few or far too many turns for the actual volt-seconds.

Determine the turns needed by the transformer voltage/flux problem, then design the magnetic reluctance to obtain Lm.

21. Gap-Dominated Lm Creates Fringing and Local Winding Loss

If an intentional gap dominates the magnetic reluctance, a useful first-pass total effective-gap estimate is:

geff≈μ0NP2AeLmg_{eff}\approx\frac{\mu_0N_P^2A_e}{L_m}

The approximate magnetic field in the gap is:

Hg≈Bμ0H_g\approx\frac{B}{\mu_0}

A first-order gap-energy estimate is:

Wg≈B22μ0AegeffW_g\approx\frac{B^2}{2\mu_0}A_eg_{eff}

Large gaps create fringing fields that can raise nearby winding AC loss and change leakage. Physical gap placement—center leg, distributed mating surfaces, spacers, or vendor-defined gapped cores—should be evaluated with the winding geometry.

22. Integrated Leakage Changes the Core-and-Gap Trade Space

Chapter 8 may require controlled leakage as part of Lr. Core and gap choices can change that leakage field even if the winding stack is unchanged. Gap fringing can also add local field to the conductor and alter AC loss.

  • Core window width and winding separation available for leakage control.
  • Gap location relative to primary/secondary turns.
  • Sectional bobbin availability.
  • Planar versus wound construction.
  • Nearby metal and shield placement.
  • Ability to hold leakage and Lm simultaneously through production tolerance.

Chapter 11 will return to the detailed winding arrangement, leakage, and capacitance tradeoff after conductor requirements are known.

23. Worked Example — Core Area and Flux for the 500 W / 48 V LLC

WORKED DESIGN EXAMPLE

500 W / 48 V LLC — Core Area and Flux

Continue the prior design thread: n = 33/8 = 4.125, VS,eff = 48.5 V, NP = 33 provisional turns, nominal fr = 150 kHz, low-line operating frequency ≈ 132 kHz, high-line operating frequency ≈ 169 kHz, and Lm = 158.5 µH.

Assume a preliminary peak-flux design target of 0.12 T for the core-screening calculation. This is not a material limit; it must later be checked against the selected ferrite’s loss and hot-saturation data.

The approximate flat-topped primary winding magnitude is:

VP,flat≈4.125(48.5)≈200.1 VV_{P,flat}\approx4.125(48.5)\approx200.1\ \mathrm{V}

At the low-line / minimum-frequency corner, the minimum effective area for 33 turns and Bpk ≤ 0.12 T is:

Ae,req≥200.14(132000)(33)(0.12)≈95.7 mm2A_{e,req}\ge\frac{200.1}{4(132\,000)(33)(0.12)}\approx95.7\ \mathrm{mm^2}

Choose an illustrative candidate with Ae = 100 mm² for first-pass screening. The low-line peak flux becomes:

Bpk,132k≈200.14(132000)(33)(100 mm2)≈0.115 TB_{pk,132k}\approx\frac{200.1}{4(132\,000)(33)(100\ \mathrm{mm^2})}\approx0.115\ \mathrm{T}

At nominal resonance:

Bpk,150k≈0.101 TB_{pk,150k}\approx0.101\ \mathrm{T}

At the high-line / higher-frequency operating point:

Bpk,169k≈0.090 TB_{pk,169k}\approx0.090\ \mathrm{T}

The low-line minimum-frequency corner controls flux in this simplified example even though it does not have the highest input voltage.

Worked 500 W LLC transformer example showing 33 primary turns, 100 square millimeter effective core area, and peak flux density at 132, 150, and 169 kilohertz.

Figure 9-2. Worked 500 W LLC example showing 33 primary turns, Ae = 100 mm² candidate core area, and peak flux at 132, 150, and 169 kHz.

24. Worked Example — AL and First-Pass Gap for Lm = 158.5 µH

For the Chapter 7 magnetizing-inductance target Lm = 158.5 µH and NP = 33, the required AL is:

AL,req=158.5 μH332≈145.5 nH/turn2A_{L,req}=\frac{158.5\ \mu\mathrm{H}}{33^2}\approx145.5\ \mathrm{nH/turn^2}

Using the illustrative Ae = 100 mm² and assuming the gap dominates reluctance, the first-pass total effective gap is:

geff≈μ0(33)2(100 mm2)158.5 μH≈0.86 mmg_{eff}\approx\frac{\mu_0(33)^2(100\ \mathrm{mm^2})}{158.5\ \mu\mathrm{H}}\approx0.86\ \mathrm{mm}

ENGINEERING CAUTION

0.86 mm Is an Effective-Gap Estimate, Not a Manufacturing Drawing Dimension

Core reluctance, fringing, actual gap placement, mating-surface geometry, tolerance, adhesive/spacer thickness, and vendor AL data will change the required physical gap.

Use the selected core manufacturer’s AL-versus-gap data or calibrated magnetic model for the production gap.

Illustrative LLC transformer ferrite core with a center-leg air gap showing the 158.5 microhenry magnetizing inductance target, effective core area, fringing field, and nearby conductor warning zone.

Figure 9-3. Illustrative gapped ferrite core for the 158.5 µH Lm target, showing effective gap, center-leg area, and fringing field near the winding window.

25. Worked Saturation-Margin Check

As an educational saturation-margin check only, assume the selected material’s minimum hot saturation flux density after vendor/tolerance review is 0.30 T. Using the low-line Bpk ≈ 0.115 T:

MB=0.30−0.1150.30×100%≈61.7%M_B=\frac{0.30-0.115}{0.30}\times100\%\approx61.7\%

That large saturation margin does not prove the core is suitable. At ~150 kHz, core loss and winding/thermal limits may be far more restrictive than saturation.

26. Core-Loss Verification Must Use the Selected Material Data

For the Ae = 100 mm² candidate, the next step is to choose actual ferrite materials and core sizes, obtain Ve, and query loss density at approximately 0.09–0.115 T across the 132–169 kHz operating range and expected temperature.

  • Check loss at low-line minimum frequency / highest flux.
  • Check loss near nominal full-power resonance.
  • Check loss at high-line maximum steady switching frequency.
  • Check temperature dependence of loss.
  • Check saturation data at the hottest expected core temperature.
  • Repeat after any NP, Ae, gap, or frequency change.

SOLIDMAG ENGINEERING INSIGHT

A Core Candidate Is Accepted by Loss and Temperature, Not by Flux Alone

Passing a saturation check is necessary but not sufficient.

Use vendor material curves or tools to convert the actual f/B/T operating points into loss density, then include that loss in Chapter 12 thermal iteration.

27. Core Candidate Screening and Iteration

Candidate CheckReject the Core If…
Ae / fluxRequired NP is incompatible with ratio or winding/window constraints.
Material lossCore loss exceeds the allocated loss/temperature budget.
Aw / windowConductor + insulation + leakage geometry cannot fit with manufacturing margin.
AL / gapRequired Lm needs an impractical gap or unstable production tolerance.
Leakage architectureCore/bobbin cannot achieve the Chapter 8 controlled-leakage target.
ThermalCore volume/surface and winding arrangement cannot meet hotspot limits.
MechanicalHeight, footprint, pin pattern, or keep-out requirements fail.
SourcingMaterial/core/bobbin availability does not meet product requirements.
  1. Import n, NP:NS candidate, Lm, Lr architecture, frequency range, current, isolation, thermal, and mechanical requirements.
  2. Select several ferrite material families valid across the frequency/temperature window.
  3. Select several core shapes/sizes with plausible Ae and Aw.
  4. Use the actual transformer primary-voltage waveform to calculate worst-case volt-seconds.
  5. Calculate minimum NP or minimum Ae from the chosen first-pass flux target.
  6. Choose integer NP consistent with the Chapter 6 ratio.
  7. Recalculate peak flux at every important operating corner.
  8. Check hot saturation margin.
  9. Query vendor core-loss data at actual f/B/T points.
  10. Reject loss-limited or mechanically unsuitable candidates.
  11. Calculate required AL from Lm/NP².
  12. Estimate / calculate the physical gap and fringing implications.
  13. Check whether the core/window/gap structure remains compatible with the Chapter 8 leakage target.
  14. Reserve usable window for conductor and insulation with manufacturing margin.
  15. Carry several candidates into Chapter 10 for conductor/AC-loss optimization.
  16. Iterate NP, core, material, gap, and winding until flux, Lm, leakage, loss, thermal, and fit all close.
LLC transformer core design workflow showing ferrite core screening, turns selection, flux and saturation checks, core loss, AL and gap realization, leakage compatibility, window fit, prototype correlation, and winding-design handoff.

Figure 9-4. Core, turns, flux, loss, AL, and gap design workflow from converter requirements through ferrite/core candidate screening and handoff to winding design.

LLC transformer core candidate trade-space comparing E-core, ETD, PQ, RM, and planar core families by effective area, window area, core volume, loss, gap requirement, leakage compatibility, mechanical size, and overall fit.

Figure 9-5. Core candidate trade-space comparing effective area, window area, core volume, loss, gap requirement, leakage compatibility, and mechanical size.

29. Design Handoff to Winding Current and Conductor Selection

At the end of Chapter 9, Chapter 10 should receive more than a core part number. It needs the complete magnetic candidate definition:

  • Core manufacturer/family/size and candidate ferrite material.
  • Ae, Aw, Ve, le, MLT, and bobbin data.
  • Primary turns NP and secondary turns NS from the selected ratio.
  • Worst-case Bpk / ΔB across the operating window.
  • Core-loss estimate across the important f/B/T corners.
  • Lm target and required AL.
  • Gap architecture and nominal/tolerance estimate.
  • Controlled-leakage constraints inherited from Chapter 8.
  • Usable winding window after insulation/margin reservations.

Chapter 10 now selects round wire, litz, foil, planar copper, or parallel conductors from the actual winding RMS/peak current and high-frequency loss requirements.

30. Chapter 9 Engineering Checklist

  • Core material is appropriate for the full frequency and temperature range.
  • Core shape is compatible with leakage, capacitance, insulation, and winding strategy.
  • Actual transformer primary voltage—not blindly the bridge voltage—is used for flux.
  • Volt-second balance is checked.
  • Worst-case flux corner comes from a physically possible V/f operating point.
  • Peak-to-peak flux and centered peak flux are distinguished.
  • Minimum turns / minimum Ae are calculated from a defined Bpk target.
  • Ballow considers core loss, hot saturation, and transients.
  • Hot saturation margin is explicitly calculated.
  • Core loss uses selected material data at actual f/B/T.
  • Area product is used only as a screening aid.
  • Usable window area is reserved for real conductor and insulation.
  • Lm is realized through required AL after turns are chosen for flux.
  • Gap/fringing is included in the physical design.
  • Integrated leakage requirements remain achievable with the selected core/gap/window.
  • Multiple core/material candidates have been compared before release.

CHAPTER TAKEAWAY

Turns, Flux, Lm, and Core Loss Must Be Solved Together

Faraday’s law chooses the minimum magnetic scale and turns needed for the applied volt-seconds. The Chapter 7 Lm target then determines AL/gap. The selected material and core volume determine whether the resulting flux is thermally acceptable.

A viable transformer candidate closes all three relationships simultaneously.

31. Conclusion — Turns, Core, Flux, Lm, and Gap Must Close Together

Core selection for an LLC transformer is not a catalog lookup based only on power. The core must support the actual transformer volt-seconds at the minimum operating frequency, keep flux and core loss within temperature-dependent limits, provide enough window for the winding and isolation system, and allow the required Lm and controlled leakage to be built repeatably.

Primary turns are constrained first by flux and loss. Magnetizing inductance is then realized through AL and gap. Because more turns lower core flux but increase winding resistance and complexity, the final solution is an optimization between core and copper loss rather than a minimum-turn calculation.

With a viable core/turns/gap candidate established, Chapter 10 can now convert the primary and secondary current envelopes into a practical high-frequency conductor system.

Technical References for This Chapter

The core-selection, Faraday-law, loss, and ferrite-material methods in this chapter follow established manufacturer guidance. Final designs should always use the actual selected core/material data and validate the loss/temperature result on hardware.

RESONANT CONVERTER TRANSFORMER DESIGN

Ready to Design a Resonant Converter Transformer?

Enter your resonant-converter requirements and begin a SolidMagnetics transformer design workflow built around the electrical, magnetic, winding, thermal, mechanical, and manufacturing constraints that shape a practical LLC or related resonant transformer.

Use the design interface to define the converter operating range, transformer requirements, resonant and magnetizing inductance targets, winding priorities, isolation needs, thermal limits, physical constraints, and optimization goals.

Return to the Ultimate Guide to Resonant Converter Transformer Design

READY TO APPLY THIS?

Turn Your Requirements Into a Real Magnetic Design

If you are working on a real inductor, flyback transformer, or supported LLC/resonant transformer project, SolidMagnetics can help you move faster from electrical requirements to calculated magnetic geometry and engineering output.

FOUNDING EARLY ENGINEERING ACCESS: $249   →   $49

Use coupon code EARLYACCESS for the Single Design package. This offer is intended for engineers who want to evaluate the current SolidMagnetics workflow and provide practical feedback that helps improve the platform.

What the Current Package Can Include

  • Requirements and feasibility review
  • Candidate design comparison and recommended design
  • Electrical, magnetic, loss, and thermal calculations
  • SolidWorks Reference CAD and STEP files where supported
  • Drawings, BOM, winding, and engineering data where supported
  • A basis for comparing custom geometry with commercial core and bobbin options

Early Access Offer Details

  • Single Design standard price: $249
  • Early Engineering Access price: $49
  • Coupon code: EARLYACCESS
  • Limited to 10 total qualified paid projects
  • One discounted project per customer
  • Expires February 12, 2027, or when all 10 uses are claimed
  • Brief post-delivery feedback is requested

The standard package provides a Reference CAD representation of the generated design rather than the complete underlying SolidMagnetics parametric automation structure. Fully parametric engineering CAD may be available separately for qualifying advanced or Enterprise projects.

Early Access calculations, CAD, drawings, and related deliverables are intended to accelerate engineering evaluation and prototype development. Final mechanical, electrical, thermal, insulation, regulatory, manufacturing, and production validation remains the responsibility of the customer and their engineering team.

ABOUT THE AUTHOR

Stan Gibson

Electrical Engineer & Founder, SolidMagnetics

Stan Gibson is an electrical engineer and founder of SolidMagnetics, an engineering platform focused on magnetic-component design automation. His work includes power electronics, inductor and transformer design, magnetic-core selection, winding design, thermal analysis, and manufacturable CAD development. Through SolidMagnetics, he develops technical guides, calculators, and automated design tools intended to help engineers move from electrical requirements to practical magnetic-component designs.

View Full Author Profile