Chapter 9 established a viable core, turns, flux, Lm, and gap candidate. Chapter 10 now converts the primary and secondary current envelopes into physical conductors while accounting for DC resistance, copper temperature, skin effect, proximity effect, litz-wire packing, foil thickness, planar geometry, terminations, window fill, and the winding-field interactions that determine high-frequency AC loss.
The main lesson is that conductor area solves only the low-frequency part of the problem. At LLC switching frequencies, the magnetic field created by neighboring turns and winding layers can redistribute current far more severely than isolated-conductor skin effect. The conductor type, strand size, number of layers, interleaving, foil thickness, and winding placement must therefore be chosen as one coupled winding design.
← Previous Chapter
Chapter 9 — Core Selection, Turns, Flux Density, and Saturation Margin
In This Chapter — Click to Expand
Table of Contents
DESIGN ASSUMPTION
Current Envelopes Come from the Converter Model
The transformer designer should use primary and secondary RMS/peak waveforms from the Chapter 3–7 operating model or switching simulation. Output DC current is not a substitute for winding RMS current.
The worked example uses illustrative winding-current envelopes of 2.8 A RMS primary and 10.8 A RMS secondary to demonstrate conductor sizing. These are educational values, not final simulated currents for a released converter.
A first-pass current-density target of 4 A/mm² is used only for comparison; final allowable current density is set by AC loss, window geometry, cooling, insulation, and Chapter 12 thermal results.
1. Winding Design Begins with the Actual Current Waveforms
LLC winding current is not a simple square or DC waveform. Primary current contains transferred resonant current plus magnetizing current; secondary current depends on the rectification interval and resonant operating point. Conductor sizing therefore starts with the waveform at each important line/load/frequency corner.
- Primary peak current for termination and instantaneous stress.
- Primary RMS current for copper and semiconductor conduction loss.
- Magnetizing current contribution at light load and full load.
- Secondary peak and RMS current for conductor and rectifier design.
- Burst/startup/overload currents where they exceed steady-state values.
SOLIDMAG ENGINEERING INSIGHT
The Winding Must Be Designed from the Current Spectrum, Not One Current Number
RMS current establishes total resistive heating, but harmonic content and field distribution determine how much larger RAC becomes than RDC.
The same RMS current can produce very different winding loss in two different winding structures.
2. Peak, RMS, Average, and Magnetizing Current Serve Different Checks
| Current Quantity | Primary Use |
|---|---|
| Peak current | Lead/pin stress, local current density, switch/rectifier peak stress, transient checks. |
| RMS current | Copper I²R loss and thermal design. |
| Average current | Power flow and some rectifier/termination checks. |
| Magnetizing current | Primary circulating current, ZVS support, additional primary RMS loss. |
| Harmonic spectrum | Skin/proximity AC-resistance prediction. |
3. Current Density Is a First-Pass Copper-Area Constraint
A first-pass minimum copper area can be estimated from allowable RMS current density:
Equivalently:
ENGINEERING CAUTION
Current Density Is Not a Universal A/mm² Constant
Acceptable current density depends on conductor type, AC-resistance multiplier, winding location, thermal path, core temperature, insulation class, airflow, and allowable hotspot.
Use current density to generate candidates, then accept or reject them from loss and thermal analysis.
4. Calculate DC Resistance from Copper Length and Area
For copper length lCu and metallic cross-sectional area ACu:
A first-pass winding length is:
Include turns, layer transitions, lead exits, pins/tabs, center taps, and any conductor length outside the ideal bobbin window.
5. Correct Copper Resistance for Operating Temperature
Copper resistance rises with temperature:
Room-temperature DCR should therefore not be used as the final winding-loss value. Chapter 12 will iterate copper temperature and resistance together.
6. First-Pass DC Copper Loss Uses RMS Current
The first-pass DC-equivalent copper loss is:
This is a lower-bound electrical estimate at high frequency because RAC is normally greater than RDC.
7. Skin Depth Shrinks as Frequency Increases
For a good nonmagnetic conductor such as copper, skin depth is:
Therefore:
As frequency rises, AC current is increasingly confined toward conductor surfaces. Skin depth should be evaluated at the significant current harmonics, not only one nominal switching frequency.
8. Conductor Diameter Relative to Skin Depth Is Only One Loss Indicator
A useful normalized conductor diameter is:
Keeping a round strand diameter small relative to skin depth reduces isolated-conductor skin effect, but that does not guarantee low transformer winding loss because proximity effect is driven by the surrounding magnetic field.
9. Proximity Effect Can Dominate Transformer Winding Loss
TI’s magnetics design material emphasizes that proximity effect can be much more important than skin effect in transformer windings. Fields from adjacent turns and layers push AC current toward particular conductor surfaces; the effect can increase rapidly with the number of layers.
| Geometry Change | Typical Proximity-Effect Trend |
|---|---|
| More winding layers | Usually increases AC-resistance penalty. |
| Higher local MMF / leakage field | Increases eddy-current redistribution. |
| Thicker foil or large solid conductor | Can increase field-driven eddy loss if current cannot use the full thickness. |
| Effective interleaving | Can reduce field buildup and RAC, but may increase capacitance. |
| Gap fringing near conductor | Can create severe localized eddy-current loss. |

Figure 10-1. Skin and proximity current distribution in round-wire and foil transformer conductors.
10. Use RAC/RDC to Represent the Complete AC Winding Penalty
Represent the complete AC-resistance penalty with:
Thus:
and winding loss becomes:
FR should come from a winding-aware analytical model such as Dowell-based methods, a vendor calculation tool, field analysis, or measured RAC—not from skin depth alone.
11. Round Wire Works Best When Layers and Conductor Diameter Remain Manageable
Single or parallel round magnet wire is attractive because it is inexpensive, easy to terminate, and well supported by winding machines. It works best when conductor diameter and number of layers remain compatible with the operating frequency.
- Few layers.
- Moderate RMS current.
- Conductor diameter not excessively large compared with skin depth.
- Winding arrangement that limits proximity-field buildup.
- Termination and insulation requirements compatible with round wire.
12. Litz Wire Trades Strand Diameter Against Packing and Termination Complexity
Litz wire subdivides the conductor into many individually insulated strands and transposes them so strands experience a more equal average field environment. It can reduce both skin and proximity loss when strand diameter, construction, bundle size, and winding geometry are chosen correctly.
The disadvantages are reduced copper packing, larger physical bundle size, higher material cost, and more difficult stripping/termination. TI transformer-design guidance notes that every level of litz twisting reduces effective copper utilization of the winding area.
13. Estimate Litz Strand Count from Required Copper Area
For strand diameter ds:
The minimum strand count by copper area is:
Total litz copper area is:
ENGINEERING CAUTION
Strand Count from Copper Area Is Only the First Litz Check
The bundle must also fit the winding width and radial build, terminate reliably, and achieve acceptable RAC in the actual layer/field arrangement.
More or smaller strands are not automatically better once packing and termination losses are included.
14. Litz Bundle Area Is Larger Than Its Copper Area
A simple physical bundle-area estimate is:
where kpack represents the effective copper fraction after strand insulation, voids, twisting, serving, and outer insulation. Use actual supplier dimensions for released designs rather than relying on one generic packing factor.
15. Foil Can Provide High Copper Fill but Must Be Thin Enough for AC Loss
For rectangular foil of width w and thickness t:
Foil can achieve very high copper utilization and is attractive for low-turn, high-current secondary windings. TI reference designs use copper sheet on LLC secondary windings specifically to carry high current and improve space utilization.
ENGINEERING CAUTION
Do Not Select Foil Thickness from DC Area Alone
A thick foil can have low RDC and still have high RAC because proximity fields crowd current onto one or both surfaces.
Foil thickness, number of parallel foils, field orientation, interleaving, edge clearance, and termination geometry must be analyzed together.
16. Parallel Conductors Can Reduce Loss but Must Share Current
For Np equal parallel conductors:
The equivalent DC resistance is:
Current sharing follows conductor impedance. A first-pass resistive relation is:
At high frequency, equal DC resistance does not guarantee equal current sharing if the conductors occupy different field positions or have different loop inductance.
17. Planar Windings Offer Repeatability but Strong Field-Driven AC Effects
Planar windings can provide repeatable geometry, low profile, controlled interleaving, and excellent thermal spreading into copper planes. They can also create large overlapping areas and strong proximity fields, making AC loss and primary-secondary capacitance central design variables.
TI’s planar-magnetics seminar emphasizes that the magnetic field determines high-frequency current distribution in planar conductors; current may concentrate strongly on opposing surfaces rather than filling the copper thickness uniformly.
EARLY ENGINEERING ACCESS
Get Your First Custom Magnetic Design for $49
Need a custom inductor, flyback transformer, or currently supported LLC/resonant transformer design for a real project? SolidMagnetics Early Engineering Access gives you a lower-cost way to evaluate the platform while it continues to expand.
STANDARD SINGLE DESIGN PRICE: $249 • EARLY ACCESS PRICE: $49
Use coupon code EARLYACCESS. Your supported design package can include:
- Candidate magnetic design output and recommended design direction
- SolidWorks Reference CAD and STEP export where supported
- Engineering drawings, BOM, winding, and design data where supported
- A practical starting point for component matching, simulation, prototyping, or further development
Offer details: Limited to the first 10 qualified paid projects. One discounted project per customer. Expires February 12, 2027, or when all 10 uses are claimed, whichever comes first.
SolidMagnetics-generated designs are engineering starting points intended to accelerate development. Final component selection, manufacturability, tolerances, winding construction, insulation, creepage and clearance, thermal performance, regulatory requirements, and production suitability must be verified for the intended application.
18. Conductor Choice Changes Leakage and Interwinding Capacitance
Changing conductor form also changes winding geometry. A foil secondary may occupy one broad layer where round wire would require several layers; a litz bundle can be physically much larger than its copper area; a planar winding can create very high overlap.
| Conductor Choice | Leakage / Capacitance Interaction |
|---|---|
| Round wire | Flexible placement; layer count can increase leakage and proximity field. |
| Litz | Similar geometric freedom to round wire but larger bundle for the same copper area. |
| Foil | Broad overlap can lower leakage but increase winding capacitance. |
| Planar | Very repeatable overlap and spacing; leakage and capacitance can be tightly controlled but strongly coupled. |
19. Terminations, Leads, and Layer Transitions Belong in the Resistance Model
Copper length includes more than the active turns. Pins, tabs, foil neck-downs, solder joints, litz terminations, layer crossovers, and lead exits can contribute meaningful resistance and localized heating.
High-current secondaries are especially sensitive to termination resistance because the loss scales with current squared.
20. Window Fill Must Use Physical Winding Area, Not Bare Copper Area
Window fill should use the physical winding envelope—not only metallic copper cross section:
TDK winding guidance and TI transformer-design material both show that round wire, litz, foil, insulation, and voids produce very different space factors. A conductor candidate that passes AC loss but cannot be manufactured inside the usable window is infeasible.
21. Gap Fringing Can Create Severe Local Winding Eddy-Current Loss
The Chapter 9 air gap can create a strong fringing field that intersects nearby copper. This can produce eddy-current loss much larger than a simple skin-effect estimate and can create a winding hotspot adjacent to the gap.
- Move sensitive winding layers away from the gap when possible.
- Use distributed-gap cores where appropriate.
- Reduce conductor thickness near strong fringing fields.
- Use field analysis for foil/planar conductors near a large gap.
- Include fringing loss in Chapter 12 thermal validation.
ENGINEERING CAUTION
Gap Fringing Can Defeat an Otherwise Good Conductor Choice
A foil or large copper section that looks excellent from RDC can become very lossy if placed in a strong fringing field.
Core/gap and winding design must remain coupled.
22. Worked Example — Primary and Secondary Copper Area for the 500 W LLC
WORKED DESIGN EXAMPLE
500 W / 48 V LLC — First-Pass Copper Areas
Continue the 33:8, ~150 kHz design thread. For conductor-selection illustration, assume the switching model reports 2.8 A RMS primary current and 10.8 A RMS secondary current at the winding-loss-critical full-load condition.
Use a preliminary current-density target of 4.0 A/mm² only to generate conductor candidates.
Those areas are DC/thermal starting points. The final conductor may require more copper after RAC and hotspot calculations.
23. Worked Example — Skin Depth and 0.14 mm Litz Strands
For copper, the skin depth is approximately:
Consider 0.14 mm diameter strands, which are smaller than the skin depth at the top of the example’s steady-state frequency range. One strand has:
A practical supplier selection might therefore begin near 46 strands for the primary and 176 strands for the secondary, then move to available constructions with enough copper area and acceptable bundle dimensions. Proximity-effect modeling may still favor a different strand diameter or winding construction.

Figure 10-2. Worked litz-wire strand sizing for the 500 W LLC primary and secondary windings.
24. Worked Example — First-Pass Hot DC Resistance and Loss
For an illustrative primary copper length of 2.0 m and secondary copper length of 0.50 m, using the minimum copper areas above and correcting from 20 °C to 80 °C:
The combined DC-equivalent winding loss is already close to 1 W before skin effect, proximity effect, terminations, and fringing are added. That is why Chapter 12 must use RAC rather than stopping at the current-density calculation.
25. Worked Example — Secondary Foil Alternative
If the 2.70 mm² secondary copper target were implemented as one 12 mm wide foil, the DC-area thickness would be:
The resulting ~0.225 mm thickness is greater than the example’s ~0.158 mm skin depth at 169 kHz. That does not automatically reject the foil, because proximity-field direction and current on one or both surfaces matter, but it is a clear signal to evaluate RAC. Two thinner parallel foils could preserve copper area while reducing individual foil thickness.
26. Compare Round Wire, Litz, Foil, and Planar Candidates
| Conductor | Strengths | Risks / Costs | Good Candidate When |
|---|---|---|---|
| Round wire | Low cost, simple termination, easy winding | Skin/proximity loss if diameter/layers become large | Current moderate and layer count low |
| Litz | Good high-frequency current distribution when designed correctly | Low packing factor, cost, termination complexity | High-frequency wound primary or moderate/high current with multiple layers |
| Foil | High copper fill, excellent for low-turn high-current windings | Proximity/eddy loss, edge insulation, tab design | Secondary turns low and wide window available |
| Planar | Repeatable geometry, low profile, thermal spreading | Capacitance and proximity loss can be high; PCB cost | High-volume low-profile design with field-aware optimization |
| Parallel conductors | Flexible copper area and strand size | Current-sharing and termination balance | Symmetric geometry can be maintained |

Figure 10-3. Comparison of round wire, litz wire, foil, planar, and parallel-conductor options for an LLC transformer.
27. Recalculate Winding Loss after the Chapter 11 Winding Arrangement Is Chosen
The conductor choice cannot be finalized before Chapter 11 because winding order and interleaving change the field seen by each conductor. After the physical arrangement is selected, recalculate RAC/RDC and total winding loss.
- Update MLT and total copper length.
- Update number of layers and section widths.
- Update proximity-field / Dowell model.
- Update primary-secondary overlap and capacitance.
- Update leakage target and verify Chapter 8 Lr.
- Update window fill and manufacturability.
- Re-run Chapter 12 thermal model.

Figure 10-5. Transformer winding loss stack showing DC copper loss, skin effect, proximity effect, gap-fringing loss, leads and terminations, and temperature correction before Chapter 12 thermal validation.
28. Recommended Conductor-Selection Workflow
- Import primary and secondary RMS/peak waveforms from the converter model.
- Choose a preliminary allowable current density and calculate minimum copper area.
- Estimate copper length and hot RDC.
- Calculate skin depth over the full switching/harmonic range.
- Generate round-wire, litz, foil, planar, and parallel-conductor candidates appropriate to the turns/current.
- For litz, select candidate strand diameter and strand count, then obtain actual supplier bundle dimensions.
- For foil/planar, choose thickness and width candidates and model field-driven RAC.
- Estimate RAC/RDC using a winding-aware analytical/vendor/FEA method.
- Include termination and lead resistance.
- Check physical window fill including insulation and packing.
- Check gap-fringing exposure.
- Pass conductor candidates to Chapter 11 for section order/interleaving.
- Recalculate leakage, capacitance, RAC, and window fit after the winding arrangement is selected.
- Carry total winding loss and hotspot geometry into Chapter 12.

Figure 10-5. High-frequency conductor-selection workflow from current waveform through copper area, skin depth, conductor technology, RAC modeling, window fit, winding arrangement, and thermal iteration.
29. Design Handoff to Winding Arrangement, Leakage, and Capacitance
Chapter 11 should receive a small set of conductor candidates, not one prematurely frozen winding. For each candidate provide:
- Primary and secondary conductor type.
- Metallic copper area and physical insulated dimensions.
- Strand count/diameter for litz or thickness/width for foil.
- Estimated hot RDC.
- Preliminary RAC/RDC over important frequencies.
- Maximum allowed layers/sections.
- Termination geometry constraints.
- Gap-fringing restrictions.
- Window area consumed.
- Any required parallel paths.
30. Chapter 10 Engineering Checklist
- Primary/secondary RMS currents come from the actual converter waveform.
- Peak and RMS currents are not interchanged.
- Current density is used only as a candidate-generation rule.
- Hot copper resistance is used.
- Copper length includes leads, transitions, and terminations.
- Skin depth is evaluated across the actual frequency range.
- Proximity effect is included.
- RAC/RDC is calculated or measured for the actual winding geometry.
- Litz strand diameter and strand count are both justified.
- Litz physical bundle size—not copper area alone—fits the window.
- Foil thickness is checked for high-frequency field loss.
- Parallel-conductor current sharing is verified.
- Planar copper is evaluated with field-driven current distribution.
- Gap-fringing exposure is checked.
- Window fill uses physical insulated winding area.
- Termination loss is included for high-current windings.
- Conductor selection remains compatible with Chapter 8 controlled leakage.
- Final winding loss will be recalculated after Chapter 11 arrangement.
CHAPTER TAKEAWAY
Copper Area Sets the Floor; AC Field Distribution Sets the Final Winding
A conductor must first provide enough copper area for RMS current and temperature. At LLC frequencies, however, the final loss depends strongly on where the conductor sits in the winding field and how current redistributes inside it.
The best winding is therefore a field-aware geometry, not simply the largest conductor that fits.
31. Conclusion — Copper Area Is Necessary but High-Frequency Field Control Determines the Final Winding
High-frequency resonant-transformer winding design begins with RMS current and copper area but cannot end there. Skin effect, proximity effect, gap fringing, winding layers, interleaving, conductor form, packing factor, and termination geometry can make RAC several times RDC if the physical structure is poorly chosen.
Round wire, litz, foil, planar copper, and parallel conductors are all viable technologies when matched to the current waveform and winding field. Litz is not automatically lowest loss, foil is not automatically too thick, and planar is not automatically high efficiency—the geometry determines the result.
With conductor candidates now defined, Chapter 11 can arrange the windings to control leakage and capacitance while minimizing proximity loss and preserving the insulation system.
Technical References for This Chapter
The high-frequency winding principles in this chapter follow established TI and TDK magnetics guidance. Final conductor choices should use actual supplier dimensions, winding-aware RAC calculations, and prototype temperature/impedance measurements.
- Texas Instruments SLUP126 — Power Transformer Design.
- Texas Instruments SLUP132 — Magnetics Design Handbook.
- Texas Instruments SLUP338 — High-Frequency Transformer Winding / Skin and Proximity Effects.
- Texas Instruments — Designing Planar Magnetics.
- TDK Electronics — Ferrite Magnetic Design Tool.
- TDK Electronics — Ferrite Winding Processing Notes.
Related SolidMagnetics Resources
Chapter 9 — Core, Turns, Flux, and Saturation
Review the core, turns, gap, and usable window that constrain conductor selection.
Chapter 11 — Winding Arrangement, Leakage, and Capacitance
Chapter 12 — Core Loss, Copper Loss, and Thermal Design
Combine final RAC winding loss with core loss and temperature rise.
Chapter 13 — Isolation, Insulation, and EMI
Verify conductor insulation, creepage, clearance, winding margins, and common-mode capacitance.
Chapter 14 — Manufacturing, Testing, and Validation
Turn conductor, DCR, ratio, leakage, dielectric, and dimensional requirements into production tests.
Ultimate Guide to Resonant Converter Transformer Design
RESONANT CONVERTER TRANSFORMER DESIGN
Ready to Design a Resonant Converter Transformer?
Enter your resonant-converter requirements and begin a SolidMagnetics transformer design workflow built around the electrical, magnetic, winding, thermal, mechanical, and manufacturing constraints that shape a practical LLC or related resonant transformer.
Use the design interface to define the converter operating range, transformer requirements, resonant and magnetizing inductance targets, winding priorities, isolation needs, thermal limits, physical constraints, and optimization goals.
Return to the Ultimate Guide to Resonant Converter Transformer Design
← Previous Chapter
Chapter 9 — Core Selection, Turns, Flux Density, and Saturation Margin
READY TO APPLY THIS?
Turn Your Requirements Into a Real Magnetic Design
If you are working on a real inductor, flyback transformer, or supported LLC/resonant transformer project, SolidMagnetics can help you move faster from electrical requirements to calculated magnetic geometry and engineering output.
FOUNDING EARLY ENGINEERING ACCESS: $249 → $49
Use coupon code EARLYACCESS for the Single Design package. This offer is intended for engineers who want to evaluate the current SolidMagnetics workflow and provide practical feedback that helps improve the platform.
What the Current Package Can Include
- Requirements and feasibility review
- Candidate design comparison and recommended design
- Electrical, magnetic, loss, and thermal calculations
- SolidWorks Reference CAD and STEP files where supported
- Drawings, BOM, winding, and engineering data where supported
- A basis for comparing custom geometry with commercial core and bobbin options
Early Access Offer Details
- Single Design standard price: $249
- Early Engineering Access price: $49
- Coupon code: EARLYACCESS
- Limited to 10 total qualified paid projects
- One discounted project per customer
- Expires February 12, 2027, or when all 10 uses are claimed
- Brief post-delivery feedback is requested
The standard package provides a Reference CAD representation of the generated design rather than the complete underlying SolidMagnetics parametric automation structure. Fully parametric engineering CAD may be available separately for qualifying advanced or Enterprise projects.
Early Access calculations, CAD, drawings, and related deliverables are intended to accelerate engineering evaluation and prototype development. Final mechanical, electrical, thermal, insulation, regulatory, manufacturing, and production validation remains the responsibility of the customer and their engineering team.