Chapter 10 selected high-frequency conductor candidates. Chapter 11 now arranges those conductors physically inside the transformer window so the finished winding simultaneously meets the Chapter 8 resonant-leakage target, controls primary-to-secondary capacitance, avoids excessive proximity loss, preserves isolation spacing, balances multiple secondary paths, and remains manufacturable.
This is one of the most coupled stages in resonant-transformer design. More interleaving and overlap usually improve coupling and reduce leakage/AC winding field, but increase primary-secondary capacitance. More separation usually lowers capacitance but raises leakage and can increase proximity loss. The best stack is therefore not the one with minimum leakage or minimum capacitance—it is the geometry that satisfies both electrical targets with acceptable winding loss and safety margin.
← Previous Chapter
In This Chapter — Click to Expand
Table of Contents
DESIGN ASSUMPTION
Geometry Is Evaluated as an Electrical Structure
The simplified capacitance equations use overlap area, dielectric thickness, and dielectric constant only as first-pass screening tools. Real transformer windings have distributed voltage, fringing electric fields, leads, shields, bobbin walls, margins, and neighboring conductors.
Leakage and capacitance should ultimately be evaluated using a geometry-aware analytical model, field analysis, or prototype measurements that match the terminal conditions used by the converter model.
The Chapter 8 total resonant-inductance target remains 31.7 µH for the continuing 500 W example; the final share produced by transformer leakage depends on the selected external/integrated/hybrid architecture.
1. Winding Arrangement Is Part of the LLC Resonant Circuit
In an LLC transformer, winding order changes electrical circuit parameters. It changes coupling, effective leakage inductance, winding AC resistance, primary-secondary capacitance, common-mode current, and sometimes the resonant frequency itself.
The winding drawing is therefore part of the resonant-circuit definition—not merely a manufacturing document.
2. Three Competing Objectives: Leakage, Capacitance, and AC Resistance
| Objective | Geometry Direction That Often Helps | Typical Cost |
|---|---|---|
| Lower leakage | More overlap / interleaving | Higher interwinding capacitance |
| Lower CPS | More separation, less overlap, thicker dielectric | Higher leakage and potentially higher AC field |
| Lower proximity loss | Better ampere-turn balance / more effective interleaving | More interfaces and capacitance |
| Higher isolation margin | Larger spacing / barriers / margin tape | Less usable window and overlap |
| Repeatable manufacturing | Simple sections and hard bobbin features | May limit electrical optimization |
SOLIDMAG ENGINEERING INSIGHT
Leakage, Capacitance, and RAC Form a Three-Way Tradeoff
Optimizing only leakage can create an EMI problem. Optimizing only capacitance can create a resonant-inductance or copper-loss problem.
The winding stack should be ranked by all three quantities together.
3. Primary-to-Secondary Capacitance Begins with Geometry
For two broad overlapping conductors separated by a nearly uniform dielectric, a first-pass capacitance estimate is:
Larger overlap area Aov and higher dielectric constant εr increase capacitance; larger dielectric spacing d reduces it.
4. Interwinding Capacitance Carries Common-Mode Displacement Current
Fast transformer winding voltage transitions drive common-mode displacement current through interwinding capacitance:
TI notes that primary-secondary capacitance provides a direct path for switching noise across the isolation barrier. This becomes especially important in systems with high dv/dt semiconductor nodes or large common-mode voltage movement.
5. Capacitive Impedance Falls with Frequency
The magnitude of capacitive reactance is:
The same parasitic capacitance becomes a lower-impedance path at higher frequency, so fast edges can couple strongly even when the fundamental switching frequency is only hundreds of kilohertz.
6. Electric-Field Energy Provides a Better Capacitance Model for Complex Geometry
For complex geometry, electric-field energy provides a more general capacitance calculation:
An effective terminal capacitance can then be extracted as:
This is useful for 2D/3D electrostatic FEA because the same CAD winding geometry can be used to calculate capacitance after tape, margins, shields, and bobbin walls are included.
7. Distributed Winding Voltage Means Simple Parallel-Plate Area Is Only a First Pass
Turns within a winding do not all sit at the same voltage. The effective terminal capacitance is therefore not simply the sum of every local plate capacitance. A useful energy-weighted approximation is:
ENGINEERING CAUTION
Do Not Treat Every Overlap Area as Being at Full Primary-to-Secondary Voltage
Winding voltage is distributed along the turns, and interleaving changes which local voltage segments face each other.
Use the plate formula for geometry trends; use a distributed network or field-energy model for final CPS.
8. Leakage Inductance Is the Magnetic Dual of the Capacitance Problem
Leakage is the magnetic-field-energy counterpart of the capacitance problem:
The same winding separation that changes the electric field also changes the leakage magnetic field. That is why leakage and capacitance move in opposite directions so often.
9. Interleaving Reduces Leakage but Usually Increases Capacitance
Interleaving places primary and secondary sections closer together and balances ampere-turns over shorter distances. TI’s planar-magnetics example shows that adding one level of interleaving can halve leakage in the example structure while doubling interwinding capacitance. The exact factors are geometry specific, but the direction of the tradeoff is broadly useful.
ENGINEERING CAUTION
Do Not Turn the TI Example into a Universal 2× Rule
Leakage and capacitance scaling depend on number of sections, overlap, dielectric thickness, winding breadth, turns distribution, and core/window geometry.
Use the example to understand direction—not as a production formula.
10. Split-Primary Interleaving Can Also Reduce Proximity Loss
A split primary such as P/2–S–P/2 can reduce leakage and proximity-field buildup because secondary ampere-turns are bounded by primary sections. It can also expose the secondary to two primary interfaces instead of one, increasing capacitance.
This is why Chapter 10 RAC must be recalculated after the layer stack is selected.
11. P-S, P/2-S-P/2, and Sectional Windings Occupy Different Trade Spaces
| Arrangement | Leakage Trend | CPS Trend | AC-Loss Trend | Best Fit |
|---|---|---|---|---|
| P–S | Moderate | Moderate | Depends on layers/field | Simple baseline |
| P/2–S–P/2 | Lower | Higher | Often lower field buildup | External-Lr or low-leakage transformer |
| Separated P | S chambers | Higher | Lower | Can raise leakage-field proximity loss | Integrated/high-Lr or low-CPS designs |
| Sectioned / partial overlap | Adjustable | Adjustable | Requires geometry-specific analysis | Hybrid optimization |

Figure 11-1. Comparison of P–S, P/2–S–P/2, and separated/sectional winding arrangements with leakage-field and capacitance trends.
12. Insulation Thickness Reduces Capacitance but Raises Leakage
Increasing primary-secondary insulation thickness reduces capacitance because d increases in the capacitance equation. TI planar guidance notes that the same increased spacing raises leakage inductance.
That spacing may be electrically required by Chapter 13 safety rules, so the resonant design must absorb the leakage consequence rather than treating insulation thickness as an independent mechanical detail.
13. Dielectric Constant Changes Capacitance without Directly Changing Leakage
Lower-permittivity insulation reduces capacitance without directly requiring more magnetic separation. This makes dielectric constant an attractive EMI parameter when materials satisfying safety, thermal, mechanical, and manufacturing requirements are available.
14. Winding Breadth and Overlap Are Powerful Geometry Variables
Increasing winding breadth or overlap improves coupling and often reduces AC winding resistance by spreading ampere-turns across a wider region. The same increased facing area increases capacitance.
TI’s planar guidance explicitly identifies winding breadth/interleaving as a variable that lowers leakage and AC resistance while increasing interwinding capacitance.
15. Foil and Planar Windings Make Overlap Especially Important
Foil and planar windings create large, well-defined facing areas, so overlap length and dielectric thickness become particularly powerful capacitance controls. This geometry can also make leakage and RAC very repeatable if fabrication tolerances are controlled.
The disadvantage is that a small change in overlap or interleaving can create a large capacitance change because the active area is broad and continuous.
16. Litz and Round Wire Add Packing and Layer Geometry to the Problem
Round wire and litz reduce the simple plate-like overlap, but their physical bundle height, layer packing, and turn-to-turn placement create a distributed capacitance network. Litz also occupies more physical window than its metallic copper area, which can force additional layers and indirectly change leakage.
17. Electrostatic Shields Redirect Common-Mode Current but Add Their Own Capacitances
A properly applied electrostatic shield can intercept displacement current that would otherwise couple directly from primary to secondary. The shield creates separate primary-to-shield and shield-to-secondary capacitances:
The shield does not eliminate capacitance; it redirects the current path. It also occupies winding space, can increase leakage through added separation, and may create eddy-current loss if implemented as a closed conductive turn.
ENGINEERING CAUTION
Never Create a Closed One-Turn Shield Around the Core Flux
An electrostatic shield must be arranged so it cannot behave as a shorted transformer turn.
Its termination, overlap, and gap must follow a validated construction.
18. Shield Termination Must Be Chosen from the EMI Current Path
If a primary-referenced shield intercepts a fast primary voltage transition, an approximate shield current is:
The shield should terminate to a quiet node that returns this current without injecting it into sensitive circuitry. The correct node depends on topology, chassis/earth strategy, Y-capacitor network, and EMI current paths.
19. Center-Tapped and Multiple Secondaries Need Geometric Symmetry
Center-tapped secondaries and multiple secondary paths should be geometrically symmetric when the converter expects symmetric electrical behavior. Differences in overlap, lead exit, layer position, or distance from the primary can create unequal leakage, capacitance, and AC resistance.
EARLY ENGINEERING ACCESS
Get Your First Custom Magnetic Design for $49
Need a custom inductor, flyback transformer, or currently supported LLC/resonant transformer design for a real project? SolidMagnetics Early Engineering Access gives you a lower-cost way to evaluate the platform while it continues to expand.
STANDARD SINGLE DESIGN PRICE: $249 • EARLY ACCESS PRICE: $49
Use coupon code EARLYACCESS. Your supported design package can include:
- Candidate magnetic design output and recommended design direction
- SolidWorks Reference CAD and STEP export where supported
- Engineering drawings, BOM, winding, and design data where supported
- A practical starting point for component matching, simulation, prototyping, or further development
Offer details: Limited to the first 10 qualified paid projects. One discounted project per customer. Expires February 12, 2027, or when all 10 uses are claimed, whichever comes first.
SolidMagnetics-generated designs are engineering starting points intended to accelerate development. Final component selection, manufacturability, tolerances, winding construction, insulation, creepage and clearance, thermal performance, regulatory requirements, and production suitability must be verified for the intended application.
20. Leakage and Capacitance Balance Should Be Measured on Both Secondary Paths
A leakage-balance metric can be written:
A similar capacitance-balance metric is:
These metrics help catch a winding that has the correct average Lr/CPS but alternates between two different resonant or common-mode conditions.
21. Creepage, Clearance, and Margin Requirements Reduce Available Overlap
Creepage, clearance, margin tape, sleeving, triple-insulated wire, bobbin barriers, and insulation-system requirements consume winding breadth and increase separation. Those constraints can increase leakage and reduce the overlap available for low RAC.
22. Gap Fringing and Leakage Fields Can Change the Best Layer Order
Gap fringing and intentional leakage fields can make one layer order thermally much worse than another. A broad foil placed next to a center-leg gap can see strong transverse field and develop high eddy-current loss even if the same foil works well farther from the gap.
Layer order should therefore be reviewed against both electric-field/capacitance goals and magnetic-field/RAC goals.
23. Nearby PCB Copper and Shields Become Part of the Capacitance Matrix
Primary-secondary capacitance is only one element of the real capacitance network. Windings also couple to core coatings, shields, PCB copper, chassis, heat spreaders, and nearby metal. At very high dv/dt, those additional paths can dominate the common-mode loop.
A capacitance-matrix or electrostatic FEA model is valuable when the transformer sits near grounded or switching conductive structures.
24. Manufacturing Tolerance Must Be Included in Leakage and Capacitance Targets
For the simple plate model, first-order capacitance variation is approximately:
Bobbin dimensions, tape thickness, foil placement, winding tension, layer count, conductor OD, and section position can therefore become production capacitance tolerances. Leakage must be toleranced at the same time.
25. FEA Can Extract Both Magnetic Leakage Energy and Electric Capacitance Energy
The Chapter 8 magnetic-energy method and this chapter’s electric-energy method can use the same 3D CAD winding geometry:
This creates a strong automation path: sweep winding positions and insulation thicknesses, extract Llk and CPS, estimate field-driven conductor loss, and reject geometries before physical prototypes are built.

Figure 11-2. Multi-physics winding optimization using the same CAD geometry for magnetic leakage-field energy, electric-field capacitance, and conductor AC-loss analysis.
26. Measure Capacitance and Leakage with Defined Terminal Conditions
Leakage and capacitance measurements must use defined terminal conditions. Record which winding is driven, which windings are open/shorted, measurement frequency, amplitude, fixture compensation, shield connections, and temperature.
- Primary leakage with specified secondary short condition.
- Secondary-path leakage measured symmetrically where applicable.
- Primary-secondary capacitance with all turns/sections connected as in the product.
- Capacitance to shield/core/chassis if those are controlled parameters.
- RAC/RDC measurement or impedance sweep for winding-loss correlation.
27. Worked Geometry Example — Overlap and Insulation Set CPS
WORKED GEOMETRY EXAMPLE
First-Pass Primary-Secondary Capacitance
Use a deliberately simplified plate model to compare winding geometries. Assume an effective overlap area of 200 mm², insulation thickness of 0.25 mm, and relative dielectric constant εr = 3.2.
The example is for geometry intuition only; a real wound transformer’s distributed voltage and fringing fields require a better model.
If an interleaved stack creates two similar primary-secondary interfaces, a crude area-scaling estimate is:
If a separated arrangement reduces overlap to 150 mm² and doubles insulation separation to 0.50 mm:

Figure 11-3. Worked overlap/insulation capacitance comparison for baseline, interleaved, and separated winding geometries.
28. Worked EMI Example — dv/dt Turns Picofarads into Ampere-Level Edge Current
At a fast common-mode transition of 50 V/ns, the 22.7 pF first-pass capacitance produces an instantaneous ideal displacement-current estimate of:
This is an edge-current estimate, not a continuous RMS current. Actual current is shaped by device output capacitance, loop inductance, PCB/chassis capacitances, edge shape, and the EMI return network.
At a 200 V differential voltage, the electric-field energy represented by the same lumped capacitance is:
SOLIDMAG ENGINEERING INSIGHT
Picofarads Can Matter When dv/dt Is Very Large
The capacitance value may look numerically small, but the current is proportional to dv/dt.
This is why high-efficiency fast-switching converters can become EMI-limited by transformer geometry.
29. Compare Three Winding Arrangements for the 500 W LLC
| Candidate Stack | Leakage | CPS | RAC / Proximity | Best Use in 500 W Design |
|---|---|---|---|---|
| P–S | Moderate | Moderate | Moderate baseline | Hybrid Lr starting point |
| P/2–S–P/2 | Low | High | Often favorable | External-Lr / low-leakage candidate |
| Separated / partial overlap | High | Low | Potentially higher field-driven loss | Integrated-Lr / low-CPS candidate |
The exact Chapter 8 leakage target determines which candidate is most promising. If the transformer must supply most of the 31.7 µH Lr, aggressive interleaving may make the leakage target impossible. If Lr is external, the interleaved candidate may offer lower winding loss at the cost of higher CPS.

Figure 11-4. 500 W LLC winding-stack trade-space comparing leakage, CPS, RAC, and the external/hybrid/integrated Lr architecture.
30. Recalculate Chapter 8 Lr and Chapter 10 RAC after Choosing the Stack
After choosing a winding stack, return to both Chapters 8 and 10. The selected geometry changes effective leakage and AC resistance at the same time.
- Recalculate / measure Llk and update external Lr if hybrid.
- Regenerate resonant frequency and gain if total Lr moved.
- Recalculate RAC/RDC for the chosen layer structure.
- Recalculate CPS and common-mode current.
- Recheck window fill, insulation, and manufacturability.
- Recheck secondary-path symmetry.
- Pass final loss and field geometry to Chapter 12.
31. Recommended Winding-Arrangement Design Workflow
- Import conductor candidates, core/gap geometry, Lm, total Lr, CPS/EMI target, insulation requirements, and usable window.
- Choose several baseline winding orders: P–S, split-primary interleaved, sectional/partial-overlap, or topology-specific variants.
- Calculate first-pass overlap capacitance and magnetic leakage trends.
- Model distributed winding voltage for a better CPS estimate.
- Calculate / simulate leakage-field and proximity-loss behavior.
- Add safety insulation, margins, shields, and lead exits.
- Recalculate CPS, leakage, RAC, and fill after those physical additions.
- Check center-tap / multiple-secondary balance.
- Evaluate gap-fringing and nearby metal/PCB effects.
- Run electrostatic and magnetic FEA for tightly optimized geometries.
- Prototype the best candidates.
- Measure Llk, CPS, RAC/DCR, and winding balance with defined terminal conditions.
- Correlate measurements to the converter gain/EMI/thermal model.
- Freeze the geometry dimensions that materially control leakage, capacitance, and loss.
- Release the final stack to Chapter 12 for loss and thermal closure.

Figure 11-5. Winding-arrangement optimization workflow from conductor/core constraints through leakage, capacitance, RAC, safety geometry, FEA, prototype measurement, and thermal handoff.
32. Design Handoff to Loss and Thermal Design
Chapter 12 should receive the final physical stack and its loss-related electrical parameters:
- Winding order and section definition.
- Conductor type and insulated dimensions.
- Measured/modeled hot RDC and RAC over frequency.
- Final transformer leakage and total Lr allocation.
- Primary-secondary capacitance and any shield capacitances.
- Gap/fringing field exposure.
- Lead and termination resistance.
- Window fill and thermal contact paths.
- Secondary-path leakage/capacitance imbalance.
33. Chapter 11 Engineering Checklist
- Winding order is treated as an electrical design variable.
- Leakage, CPS, and RAC are evaluated together.
- CPS first-pass geometry uses overlap, spacing, and εr.
- Distributed winding voltage is included in the final capacitance model.
- Interleaving tradeoff is explicit.
- Insulation thickness and dielectric constant are included.
- Foil/planar overlap is controlled.
- Litz/round-wire physical layer buildup is included.
- Electrostatic shield is not a closed turn and has a defined termination.
- Center-tapped / multiple-secondary geometry is symmetric.
- Leakage and capacitance balance are measured where required.
- Creepage/clearance/margins are included before final electrical optimization.
- Gap-fringing and nearby-metal effects are checked.
- Manufacturing tolerances are propagated into Llk and CPS.
- Magnetic and electrostatic FEA are used when geometry is tightly coupled.
- Measurement terminal conditions are defined.
- Chapter 8 total Lr is recalculated after the stack is chosen.
- Chapter 10 RAC is recalculated after the stack is chosen.
- Final stack provides loss/capacitance data to Chapter 12.
CHAPTER TAKEAWAY
The Best Winding Stack Is Not the One with the Lowest Leakage
An LLC transformer may intentionally need leakage, and reducing it through aggressive interleaving can create excessive capacitance.
The correct stack achieves the required Lr while keeping CPS, RAC, isolation, EMI, and manufacturability inside their limits.
34. Conclusion — Winding Geometry Is a Multi-Physics Optimization
Winding arrangement is where resonant-transformer electrical design becomes physical geometry. Every change in overlap, interleaving, sectioning, dielectric thickness, conductor form, shield placement, and lead routing can alter leakage inductance, parasitic capacitance, AC resistance, isolation spacing, and thermal behavior at the same time.
For an integrated LLC transformer, leakage is intentionally controlled rather than minimized. For any isolated high-frequency transformer, CPS must be controlled because fast voltage transitions can drive substantial common-mode current. And for every high-current winding, proximity fields must be managed because copper area alone does not determine RAC.
With the winding stack now defined, Chapter 12 can calculate the complete core-plus-copper loss and verify whether the design meets efficiency and temperature requirements.
Technical References for This Chapter
The winding-arrangement tradeoffs in this chapter follow established TI and Würth Elektronik guidance on interleaving, leakage, interwinding capacitance, AC winding resistance, and transformer EMI. Final designs should correlate analytical/FEA results to prototype impedance and EMI measurements.
- Texas Instruments — Designing Planar Magnetics.
- Texas Instruments — Transformer Leakage vs. Primary-Secondary Capacitance Tradeoffs.
- Texas Instruments — Transformer Parasitic Capacitance and Common-Mode Noise.
- Texas Instruments — LLC Leakage Inductance and Low Interwinding Capacitance.
- Würth Elektronik — Transformer Design for EMC.
Related SolidMagnetics Resources
Chapter 8 — Resonant Inductance and Controlled Leakage
Review the Lr architecture and leakage measurement definitions that the winding stack must realize.
Chapter 10 — Winding Current and Conductor Selection
Review conductor candidates, litz/foil/planar choices, and preliminary RAC targets.
Chapter 12 — Loss and Thermal Design
Continue into final core loss, winding AC loss, efficiency, and temperature rise.
Chapter 13 — Isolation, Insulation, and EMI
Finalize insulation spacing, shields, creepage, clearance, and common-mode EMI controls.
Chapter 14 — Manufacturing, Testing, and Validation
Convert Llk, CPS, DCR/RAC, ratio, dielectric, and symmetry requirements into production tests.
Ultimate Guide to Resonant Converter Transformer Design
RESONANT CONVERTER TRANSFORMER DESIGN
Ready to Design a Resonant Converter Transformer?
Enter your resonant-converter requirements and begin a SolidMagnetics transformer design workflow built around the electrical, magnetic, winding, thermal, mechanical, and manufacturing constraints that shape a practical LLC or related resonant transformer.
Use the design interface to define the converter operating range, transformer requirements, resonant and magnetizing inductance targets, winding priorities, isolation needs, thermal limits, physical constraints, and optimization goals.
Return to the Ultimate Guide to Resonant Converter Transformer Design
← Previous Chapter
READY TO APPLY THIS?
Turn Your Requirements Into a Real Magnetic Design
If you are working on a real inductor, flyback transformer, or supported LLC/resonant transformer project, SolidMagnetics can help you move faster from electrical requirements to calculated magnetic geometry and engineering output.
FOUNDING EARLY ENGINEERING ACCESS: $249 → $49
Use coupon code EARLYACCESS for the Single Design package. This offer is intended for engineers who want to evaluate the current SolidMagnetics workflow and provide practical feedback that helps improve the platform.
What the Current Package Can Include
- Requirements and feasibility review
- Candidate design comparison and recommended design
- Electrical, magnetic, loss, and thermal calculations
- SolidWorks Reference CAD and STEP files where supported
- Drawings, BOM, winding, and engineering data where supported
- A basis for comparing custom geometry with commercial core and bobbin options
Early Access Offer Details
- Single Design standard price: $249
- Early Engineering Access price: $49
- Coupon code: EARLYACCESS
- Limited to 10 total qualified paid projects
- One discounted project per customer
- Expires February 12, 2027, or when all 10 uses are claimed
- Brief post-delivery feedback is requested
The standard package provides a Reference CAD representation of the generated design rather than the complete underlying SolidMagnetics parametric automation structure. Fully parametric engineering CAD may be available separately for qualifying advanced or Enterprise projects.
Early Access calculations, CAD, drawings, and related deliverables are intended to accelerate engineering evaluation and prototype development. Final mechanical, electrical, thermal, insulation, regulatory, manufacturing, and production validation remains the responsibility of the customer and their engineering team.