Chapter 12 thermally closed the transformer geometry. Chapter 13 now finalizes the isolation system and common-mode EMI behavior: working and transient voltage, insulation class, clearance, creepage, solid insulation, high-frequency voltage stress, winding margins, shields, dielectric testing, partial discharge considerations, and the primary-secondary capacitance paths that couple switching noise across the isolation barrier.
Safety and EMI cannot be optimized independently. Increasing primary-secondary spacing can improve insulation and reduce capacitance, but it increases leakage and can raise AC winding loss. Interleaving can reduce leakage and RAC, but it raises capacitance. Electrostatic shields can redirect common-mode current, but add capacitance, winding space, leakage, and potential eddy-current loss. The released construction must satisfy the applicable safety standard and the electrical/EMI requirements simultaneously.
← Previous Chapter
Chapter 12 — Core Loss, Copper Loss, Efficiency, and Thermal Design
In This Chapter — Click to Expand
Table of Contents
DESIGN ASSUMPTION
No Universal Creepage or Clearance Number Is Assumed
This chapter does not invent generic millimeter values. The required distances depend on the end-product standard, working voltage, rated impulse/transient voltage, insulation class, pollution degree, material group/CTI, altitude, field homogeneity, high-frequency stress, coating/potting qualification, and other construction details.
IEC 60664-1:2020+A1:2025 is a current basic insulation-coordination reference for low-voltage equipment, but its core scope is limited to frequencies up to 30 kHz. The guide’s ~132–169 kHz LLC example therefore also requires high-frequency insulation consideration, such as IEC 60664-4 where applicable, unless the product-specific standard supplies the governing method.
Product-specific standards and certification requirements take precedence over generic design guidance.
1. Isolation Design Starts with the End-Product Safety Standard
The transformer does not choose its own safety category. The end product determines the required insulation function, voltage category, transient environment, accessibility of the secondary circuit, and required tests.
- Identify the end-product standard before final spacing is frozen.
- Determine whether the secondary is accessible, SELV/ES1-like, chassis-referenced, floating, or connected to another hazardous circuit as defined by the governing standard.
- Determine the required insulation type and certification path.
- Record working, transient, impulse, and test voltages.
- Record pollution degree, material group/CTI, altitude, and environmental assumptions.
ENGINEERING CAUTION
A Transformer Built to One Standard Is Not Automatically Compliant in Another Product
IEC 62368-1, IEC 61010-1, IEC 61800-5-1, IEC 62109-1, automotive standards, medical standards, and other product standards can impose different insulation and test requirements.
Treat the end-product standard as a formal design input.
2. Functional, Basic, Supplementary, and Reinforced Insulation Are Different Requirements
Many safety standards distinguish functional, basic, supplementary, double, and reinforced insulation. The exact definitions and required tests must be taken from the governing standard.
| Insulation Category | General Design Role |
|---|---|
| Functional | Needed for correct circuit operation rather than protection from electric shock. |
| Basic | Primary protection against electric shock in the applicable safety architecture. |
| Supplementary | Independent insulation added to basic insulation where required. |
| Double | Basic plus supplementary insulation as defined by the applicable standard. |
| Reinforced | Single insulation system intended to provide a degree of protection equivalent to double insulation under the governing standard. |
3. Determine Peak and RMS Working Voltage from the Actual Converter
Working voltage should come from the actual differential voltage across the isolation barrier, including converter modes and waveform shape. Useful screening definitions include:
Do not assume the DC bus voltage is always identical to the transformer insulation working voltage; determine the actual circuit potentials and the product standard’s definition.
4. Transient and Impulse Voltage Drive Clearance Requirements
Clearance is commonly driven by transient/impulse voltage and insulation class, with additional correction or rules for altitude and field configuration. Determine the rated impulse or transient requirement from the end product rather than from the LLC steady-state waveform alone.
5. Clearance Is the Shortest Distance Through Air
Clearance is the shortest distance through air between conductive parts. The physical design must satisfy:
The required dclear,req comes from the applicable standard and its defined voltage/environmental conditions.
6. Creepage Is the Shortest Distance Along an Insulating Surface
Creepage is the shortest distance along the surface of an insulating material between conductive parts. The physical design must satisfy:
Creepage is strongly influenced by working voltage, pollution degree, material group/CTI, and product-specific rules.

Figure 13-1. Transformer creepage, clearance, solid-insulation thickness, bobbin margin, and winding-exit paths around the primary-secondary barrier.
7. Pollution Degree and Material Group Change the Creepage Requirement
Pollution degree represents how contamination can affect surface insulation; material group is commonly based on comparative tracking index. These quantities influence creepage requirements but not in the same way as air clearance.
ENGINEERING CAUTION
Do Not Use CTI to Reduce Air Clearance
Material tracking performance is primarily a creepage/surface-insulation issue.
Clearance is governed by air breakdown/transient considerations under the applicable standard.
8. Altitude Changes Air-Insulation Requirements
Air density falls with altitude, reducing dielectric withstand. IEC 60664-1 includes altitude correction guidance and its current edition is based on use up to 2,000 m with guidance/corrections above that altitude.
Record the maximum installation altitude before finalizing pins, bobbin walls, winding exits, and PCB keep-outs.
9. High-Frequency Voltage Stress Matters Above 30 kHz
The current IEC 60664-1 basic standard states a core frequency scope up to 30 kHz. IEC 60664-4 addresses periodic high-frequency voltage stress above 30 kHz and up to 10 MHz when used with the base insulation-coordination framework.
The guide’s 132–169 kHz operating range therefore cannot be treated as if only low-frequency insulation stress exists. High-frequency creepage, clearance, solid insulation, testing, and partial-discharge considerations may apply depending on the end-product standard and waveform.
SOLIDMAG ENGINEERING INSIGHT
Switching Frequency Can Affect Safety Geometry, Not Just Core Loss
High-frequency voltage stress changes dielectric behavior and partial-discharge risk.
The insulation system must be reviewed against the frequency content of the actual winding voltage, not only its peak amplitude.
10. Solid Insulation Must Be Designed for Electric-Field Stress and Aging
A first-order average electric-field estimate through a solid insulation layer is:
Real fields are nonuniform at foil edges, wire crossings, tape steps, bobbin corners, lead exits, and air voids. Solid-insulation design must account for material dielectric strength, aging, temperature, frequency, mechanical stress, voids, and partial discharge—not only average V/mm.
11. Triple-Insulated Wire, Margin Tape, and Bobbin Barriers Are Construction Options
Common transformer construction options include margin tape, sleeving, triple-insulated wire, bobbin barriers, multilayer tape, molded barriers, and qualified insulation systems. Each changes usable window, leakage, capacitance, thermal path, and manufacturability.
| Construction Option | Potential Benefit | Potential Tradeoff |
|---|---|---|
| Margin tape | Creates controlled surface spacing and winding setback | Consumes winding breadth; can increase leakage. |
| Triple-insulated wire | Can simplify some insulation constructions where accepted | Larger OD, cost, termination/process controls. |
| Bobbin barrier / sectional bobbin | Repeatable mechanical separation | Higher leakage and reduced usable window. |
| Layer tape / film | Controlled solid insulation thickness | Capacitance and thermal path depend on material/thickness. |
| Sleeving | Protects lead exits / crossing conductors | Adds assembly steps and local bulk. |
12. Creepage and Clearance Must Include Leads, Pins, and Winding Exits
The shortest insulation path may occur at lead exits, pins, solder joints, foil tabs, layer transitions, or wire crossings rather than across the main winding body. The CAD drawing should therefore check three-dimensional creepage and clearance around the entire component.
13. The Insulation System Must Survive the Chapter 12 Hotspot Temperature
Use the Chapter 12 hotspot prediction and measured temperature distribution. The insulation system must remain within its allowed thermal class and long-term aging requirements at the actual hotspot, not only ambient temperature.
14. Dielectric Withstand Testing Verifies Construction — It Does Not Design It
Dielectric-withstand or hi-pot testing verifies that a manufactured insulation construction withstands the required test stress. It does not determine the required creepage, clearance, or solid-insulation thickness.
Test voltage, waveform, duration, ramp, leakage/trip threshold, terminals, and conditioning must come from the applicable standard and approved test plan.
15. Partial Discharge Can Matter for High-Voltage High-Frequency Solid Insulation
Partial discharge can erode insulation around voids or high-field regions long before gross dielectric breakdown. IEC 60664-4 includes high-frequency partial-discharge test considerations for high-frequency voltage stress.
Whether PD testing is required depends on the applicable construction/standard and insulation system. Do not add a PD test criterion unless the certification plan defines the required inception/extinction method and voltage.
16. Coating, Potting, and Moulding Need Their Own Qualification Rules
Coating, potting, and moulding can change pollution protection and solid-insulation behavior, but the spacing benefit is not automatic. IEC 60664-3 defines qualified protection approaches and test procedures for coating, potting, or moulding used for insulation coordination.
ENGINEERING CAUTION
Potting Is Not Permission to Ignore Creepage and Clearance
Reduced spacing requires a qualified protection method under the governing standard.
Material adhesion, voids, process control, thermal cycling, repairability, and partial-discharge behavior all matter.
17. Primary-Secondary Capacitance Is the Main Isolation-Barrier EMI Path
The same primary-secondary spacing that creates the safety barrier also creates a parasitic capacitance:
This capacitance forms a common-mode current path across the isolation barrier. TI identifies transformer primary-secondary capacitance as a major common-mode EMI mechanism in isolated converters.
18. Fast dv/dt Converts Picofarads into Large Edge Currents
Fast GaN/SiC edges can therefore make picofarad-level capacitance important. TI measured substantially larger common-mode current in transformer designs with larger parasitic capacitance at high switch-node slew rate.
19. Low CPS Is an LLC Advantage When Leakage Can Be Used Intentionally
An LLC transformer can intentionally tolerate more leakage than a flyback transformer because leakage can become part of Lr. That physical separation can reduce CPS and common-mode current. TI has demonstrated LLC bias-transformer designs specifically using low interwinding capacitance to reduce common-mode current injection.
The CPS limit should come from system EMI/common-mode-current analysis rather than from a generic transformer rule.
EARLY ENGINEERING ACCESS
Get Your First Custom Magnetic Design for $49
Need a custom inductor, flyback transformer, or currently supported LLC/resonant transformer design for a real project? SolidMagnetics Early Engineering Access gives you a lower-cost way to evaluate the platform while it continues to expand.
STANDARD SINGLE DESIGN PRICE: $249 • EARLY ACCESS PRICE: $49
Use coupon code EARLYACCESS. Your supported design package can include:
- Candidate magnetic design output and recommended design direction
- SolidWorks Reference CAD and STEP export where supported
- Engineering drawings, BOM, winding, and design data where supported
- A practical starting point for component matching, simulation, prototyping, or further development
Offer details: Limited to the first 10 qualified paid projects. One discounted project per customer. Expires February 12, 2027, or when all 10 uses are claimed, whichever comes first.
SolidMagnetics-generated designs are engineering starting points intended to accelerate development. Final component selection, manufacturability, tolerances, winding construction, insulation, creepage and clearance, thermal performance, regulatory requirements, and production suitability must be verified for the intended application.
20. Electrostatic Shields Redirect Current Rather Than Eliminating Capacitance
An electrostatic shield inserted between primary and secondary changes one direct capacitance path into primary-to-shield and shield-to-secondary capacitances:
If the shield were left floating, its simple series-equivalent capacitance would be:
In normal EMI use the shield is intentionally connected, so the current path is governed by the shield termination rather than by this floating series-equivalent alone.
21. Shield Termination Determines Where the Common-Mode Current Goes
TI’s current EMI guidance explains that an internal shield is normally returned to a quiet primary-side AC node so intercepted displacement current remains local to the primary instead of flowing through the secondary/chassis return path.
SOLIDMAG ENGINEERING INSIGHT
A Shield Moves Common-Mode Current; It Does Not Make the Current Disappear
The termination node decides where the displacement current closes.
Evaluate the complete primary, secondary, chassis, Y-capacitor, and PCB capacitance network before choosing the shield connection.
22. Shield Thickness and Geometry Can Add Eddy-Current Loss
TI’s recent low-EMI guidance recommends very thin copper shield layers because shield eddy-current loss can become significant at high switching frequency. A shield also increases spacing and can raise leakage.
23. Never Allow an Electrostatic Shield to Become a Closed Shorted Turn
ENGINEERING CAUTION
A Faraday Shield Must Not Become a Shorted Turn
Where a foil shield wraps around the winding window, its ends must not form a closed conductive loop around the core flux.
Provide a deliberate insulated gap/overlap construction and document it on the winding drawing.
24. Insulation Spacing and EMI Optimization Feed Back into Leakage and RAC
Increasing insulation thickness often reduces CPS and improves some dielectric margins but raises leakage and can increase Chapter 10/11 proximity loss. Adding a shield consumes window space and changes capacitance/leakage. Final isolation changes therefore require electrical and thermal feedback.
Return to Chapter 11 if the safety construction materially changes overlap, leakage, or capacitance.
25. Worked Safety Example — Define the Requirements, Do Not Guess the Distances
WORKED DESIGN EXAMPLE
400 V-Bus LLC — Define the Safety Inputs Before the Distances
For the continuing 500 W example, suppose the product team states a 400 V nominal DC primary bus and an isolated 48 V output. That is not enough information to choose a creepage or clearance distance.
The correct next step is to complete the safety requirement record. The example below intentionally leaves the final millimeter values blank until the end-product standard is identified.
| Safety Input | Illustrative / Required Entry |
|---|---|
| End-product standard | Must be identified before release. |
| Insulation function | Basic / supplementary / reinforced / other — per product standard. |
| Primary-secondary working voltage | Calculate peak and RMS from actual circuit potentials. |
| Rated impulse / transient voltage | Derive from end-product category and standard. |
| Switching fundamental | Approximately 132–169 kHz in the worked design. |
| Pollution degree | Product/environment requirement. |
| Material group / CTI | From actual bobbin/tape/PCB material. |
| Maximum altitude | Product requirement; apply standard correction. |
| Creepage requirement | Determine from governing standard — do not guess. |
| Clearance requirement | Determine from governing standard — do not guess. |
| Solid insulation / PD | Determine from construction and applicable HF rules. |
| Dielectric test | Voltage, waveform, duration, current limit from certification plan. |
ENGINEERING CAUTION
The 132–169 kHz Frequency Is Above the Basic IEC 60664-1 Frequency Scope
If IEC 60664 principles are used, high-frequency stress provisions such as IEC 60664-4 may also be relevant.
A product-specific standard may contain its own high-frequency rules or normative references; follow that path.

Figure 13-2. Safety requirement flow from product standard and voltage/environment inputs to creepage, clearance, solid insulation, high-frequency stress, and dielectric/PD test requirements.
26. Worked EMI Example — Chapter 11 CPS and Edge Current
Re-use the Chapter 11 baseline first-pass CPS = 22.7 pF. At an illustrative 50 V/ns barrier voltage transition:
For a 200 V edge, the transferred charge per idealized transition is:
These are instantaneous/lumped estimates. The measured common-mode current depends on the complete return network and edge waveform.
27. Compare Low-CPS and Baseline Winding Options
The separated Chapter 11 geometry had a first-pass CPS ≈ 8.5 pF. At the same 50 V/ns edge:
| Winding Option | First-Pass CPS | Ideal Edge Current @ 50 V/ns | Leakage Direction |
|---|---|---|---|
| Baseline overlap | 22.7 pF | ≈ 1.14 A | Moderate |
| Separated / lower overlap | 8.5 pF | ≈ 0.43 A | Higher |
| Aggressively interleaved | Higher than baseline in simple area model | Higher | Lower |
This shows why the Chapter 8 Lr architecture and EMI target are linked. A fully integrated-Lr transformer may benefit from the same separation that lowers CPS; an external-Lr design may prefer more interleaving and need another common-mode strategy.

Figure 13-3. Common-mode current comparison for baseline, low-capacitance separated, and highly interleaved LLC transformer winding options.

Figure 13-5. Final resonant-transformer isolation barrier showing approved insulation materials, creepage and clearance paths, winding margins, electrostatic shield gap and termination, and critical production dimensions.
28. Production Isolation and EMI Specifications
Convert the safety and EMI design into explicit production specifications:
- Approved insulation-system materials and part numbers.
- Primary-secondary winding order and barrier construction.
- Minimum creepage and clearance dimensions from the approved standard evaluation.
- Minimum solid-insulation layers/thickness where applicable.
- Allowed triple-insulated wire / sleeving / tape systems.
- Shield material, thickness, gap, orientation, and termination.
- Maximum primary-secondary capacitance.
- Dielectric-withstand test conditions.
- Partial-discharge test conditions if required.
- Maximum leakage current / hi-pot trip threshold as required.
- Maximum insulation-system temperature.
- Critical winding-exit and pin dimensions.
29. Measurement Conditions Must Match the Parameter Being Controlled
Parameter values depend on terminal connections and frequency. The manufacturing test plan should define:
- CPS measurement frequency, amplitude, and winding connections.
- Shield connection state during capacitance measurement.
- Dielectric test terminals, waveform, voltage, ramp, duration, trip current.
- PD test frequency/voltage and inception/extinction method if applicable.
- Environmental conditioning required before testing.
- Whether creepage/clearance is measured mechanically, optically, by gauge, or controlled by tooling.
- Traceability of tape, bobbin, sleeving, wire, and potting materials.
30. Recommended Isolation, Insulation, and EMI Workflow
- Identify the end-product safety and certification standards.
- Determine required insulation type.
- Calculate actual primary-secondary peak and RMS working voltage.
- Determine rated impulse/transient requirements.
- Record pollution degree, material group/CTI, altitude, and environmental assumptions.
- Apply the product standard and relevant insulation-coordination rules to derive creepage, clearance, and solid-insulation requirements.
- Check whether high-frequency stress rules apply to the LLC switching waveform.
- Build the physical barrier using bobbin geometry, margins, tape, wire insulation, sleeving, or qualified insulation systems.
- Recalculate leakage, CPS, RAC, and window fit after safety spacing is added.
- Calculate common-mode current from CPS and dv/dt.
- Evaluate electrostatic shield candidates and return paths.
- Check shield eddy-current loss and confirm the shield cannot become a shorted turn.
- Re-run Chapter 12 thermal analysis if insulation or shield changes heat paths/loss.
- Define production hi-pot / PD / capacitance / dimensional tests.
- Prototype and perform conducted/radiated EMI and dielectric validation.
- Freeze the certified construction and material/process controls for Chapter 14.

Figure 13-4. Isolation, insulation, and EMI workflow linking product standard, voltage stress, creepage/clearance, high-frequency insulation, CPS, shield design, thermal feedback, and validation.
31. Design Handoff to Manufacturing, Testing, and Validation
Chapter 14 should receive a frozen or certification-ready construction with explicit test limits and process controls:
- Approved core/bobbin/wire/tape/sleeving/shield materials.
- Winding order, margins, barriers, and lead routing.
- Certified/approved creepage and clearance dimensions.
- CPS maximum and measurement method.
- Leakage/Lm/ratio/DCR limits from earlier chapters.
- Hi-pot / dielectric-withstand test method.
- PD requirements where applicable.
- Maximum operating temperature and insulation class.
- Shield gap and termination definition.
- EMI validation conditions and critical PCB/chassis assumptions.
32. Chapter 13 Engineering Checklist
- End-product safety standard is identified.
- Insulation class is explicitly defined.
- Peak and RMS working voltage are calculated from actual circuit potentials.
- Transient/impulse requirement is identified.
- Creepage and clearance are kept conceptually separate.
- Pollution degree and material group/CTI are known.
- Maximum altitude is known.
- High-frequency stress above 30 kHz is evaluated under the applicable rules.
- Solid-insulation thickness/material and aging are justified.
- Lead exits, pins, foil tabs, and crossings meet spacing requirements.
- Chapter 12 hotspot is below insulation-system limits.
- Hi-pot test is defined from the applicable standard.
- PD test is included if required by the construction/standard.
- Coating/potting benefits are claimed only when qualified.
- CPS is measured/estimated and has a system-level maximum.
- dv/dt common-mode current is estimated.
- Shield termination is defined from the EMI current path.
- Shield is thin enough for acceptable eddy loss and cannot form a closed turn.
- Leakage and RAC are rechecked after safety spacing/shield changes.
- Manufacturing tests and critical material controls are documented.
CHAPTER TAKEAWAY
The Isolation Barrier Is Both a Safety Structure and an EMI Component
The same geometry that prevents electric shock also defines capacitance and common-mode noise.
A robust resonant transformer satisfies the certification requirements while deliberately controlling the displacement-current path rather than discovering it during EMI testing.
33. Conclusion — Safety and EMI Must Be Designed into the Same Geometry
Chapter 13 completes the physical transformer design by joining safety insulation and electromagnetic behavior. Creepage, clearance, solid insulation, high-frequency voltage stress, temperature, shielding, and common-mode capacitance all live in the same primary-secondary barrier.
No universal spacing number can replace the end-product standard and real operating environment. The correct approach is to derive the required insulation system from the governing safety rules, then feed that geometry back into leakage, capacitance, winding loss, and thermal analysis.
With the insulation and EMI construction now defined, Chapter 14 can create the repeatable winding instructions, tolerances, electrical tests, dielectric tests, and prototype/production validation plan.
Technical References for This Chapter
The safety and EMI guidance in this chapter uses current IEC insulation-coordination references and current TI/Würth transformer EMI guidance. Product-specific standards and certification findings remain controlling for a production design.
- IEC 60664-1:2020+A1:2025 — Insulation Coordination for Low-Voltage Equipment.
- IEC 60664-4:2005 — Consideration of High-Frequency Voltage Stress.
- IEC 60664-3:2016 — Coating, Potting, or Moulding for Protection Against Pollution.
- Texas Instruments — Demystifying Clearance and Creepage Distance for High-Voltage End Equipment.
- Texas Instruments — An Engineer’s Guide to EMI in DC/DC Regulators.
- Texas Instruments SLUP125 — Magnetics Design 3: Windings.
- Texas Instruments — Transformer Parasitic Capacitance and Common-Mode Current in Isolated Bias Topologies.
- Würth Elektronik — Design for EMC 2026.
Related SolidMagnetics Resources
Chapter 11 — Winding Arrangement, Leakage, and Capacitance
Review the winding geometry and CPS/leakage tradeoff that the insulation system modifies.
Chapter 12 — Loss and Thermal Design
Review hotspot temperatures and shield/fringing loss before freezing insulation materials.
Chapter 14 — Manufacturing, Testing, and Validation
Ultimate Guide to Resonant Converter Transformer Design
RESONANT CONVERTER TRANSFORMER DESIGN
Ready to Design a Resonant Converter Transformer?
Enter your resonant-converter requirements and begin a SolidMagnetics transformer design workflow built around the electrical, magnetic, winding, thermal, mechanical, and manufacturing constraints that shape a practical LLC or related resonant transformer.
Use the design interface to define the converter operating range, transformer requirements, resonant and magnetizing inductance targets, winding priorities, isolation needs, thermal limits, physical constraints, and optimization goals.
Return to the Ultimate Guide to Resonant Converter Transformer Design
← Previous Chapter
Chapter 12 — Core Loss, Copper Loss, Efficiency, and Thermal Design
READY TO APPLY THIS?
Turn Your Requirements Into a Real Magnetic Design
If you are working on a real inductor, flyback transformer, or supported LLC/resonant transformer project, SolidMagnetics can help you move faster from electrical requirements to calculated magnetic geometry and engineering output.
FOUNDING EARLY ENGINEERING ACCESS: $249 → $49
Use coupon code EARLYACCESS for the Single Design package. This offer is intended for engineers who want to evaluate the current SolidMagnetics workflow and provide practical feedback that helps improve the platform.
What the Current Package Can Include
- Requirements and feasibility review
- Candidate design comparison and recommended design
- Electrical, magnetic, loss, and thermal calculations
- SolidWorks Reference CAD and STEP files where supported
- Drawings, BOM, winding, and engineering data where supported
- A basis for comparing custom geometry with commercial core and bobbin options
Early Access Offer Details
- Single Design standard price: $249
- Early Engineering Access price: $49
- Coupon code: EARLYACCESS
- Limited to 10 total qualified paid projects
- One discounted project per customer
- Expires February 12, 2027, or when all 10 uses are claimed
- Brief post-delivery feedback is requested
The standard package provides a Reference CAD representation of the generated design rather than the complete underlying SolidMagnetics parametric automation structure. Fully parametric engineering CAD may be available separately for qualifying advanced or Enterprise projects.
Early Access calculations, CAD, drawings, and related deliverables are intended to accelerate engineering evaluation and prototype development. Final mechanical, electrical, thermal, insulation, regulatory, manufacturing, and production validation remains the responsibility of the customer and their engineering team.