Chapter 15: Practical Design Examples and Automation

The first fourteen chapters developed the resonant converter transformer one engineering layer at a time. Chapter 15 now reconnects those layers into complete examples and a repeatable automation architecture. The goal is not merely to produce a transformer that works once—it is to preserve the entire chain from customer requirements through equations, candidate selection, CAD, manufacturing instructions, production tests, prototype measurements, and future redesigns.

A useful automated magnetic-design system therefore does more than calculate turns. It maintains one versioned design record, rejects infeasible candidates before optimization, propagates tolerances, generates buildable geometry, produces manufacturing/test outputs from the same source data, and records which requirement each output has satisfied. Human engineering review remains essential wherever safety certification, incomplete material data, novel geometry, field correlation, or product-specific judgment cannot be proven automatically.

In This Chapter — Click to Expand

Table of Contents

DESIGN ASSUMPTION

Examples Are Engineering Demonstrations, Not Released Products

Example A continues the same 500 W / 48 V educational thread used throughout Chapters 4–14. Several inputs—including final ferrite grade, final core part number, exact product safety standard, and final production tolerances—were intentionally left open because they require real product and supplier data.

Example B is a second illustrative first-pass design used to show how automation branches when priorities change. Its numerical values are candidate inputs, not a released transformer.

The automation section describes the architecture and outputs a SolidMagnetics resonant-design workflow can generate; it does not claim that every resonant-design automation stage is already live on the public site.

1. Chapter 15 Connects the Entire Resonant Transformer Design Chain

The real design object is not the transformer alone. It is the traceable relationship between requirements, resonant converter behavior, magnetic geometry, manufacturing limits, and measured validation data.

Complete resonant transformer traceability chain from product requirements through equations, candidate selection, magnetic geometry, CAD and manufacturing outputs, production testing, prototype validation, and design feedback.
Image Title

Figure 15-1. Complete resonant-transformer traceability chain from product requirements through equations, candidate selection, magnetic geometry, CAD/manufacturing outputs, production tests, prototype validation, and design feedback.

2. A Practical Example Should Preserve Traceability, Not Just Final Numbers

A practical example should preserve the assumptions that created each value. The nominal Lm, for example, is only meaningful together with Lr, Ln, load/gain window, ZVS margin, primary turns, AL/gap, production tolerance, and measurement condition.

𝐲=F(𝐫,𝐝,vcalc,vdata,vcad)\mathbf{y}=F(\mathbf{r},\mathbf{d},v_{calc},v_{data},v_{cad})

The output vector y should therefore record both the result and the model/data versions that produced it.

3. Example A — 500 W / 48 V Half-Bridge LLC Requirements

EXAMPLE A

500 W / 48 V Half-Bridge LLC

Continue the guide design: approximately 380–420 VDC input bus, 48 V / 500 W output, half-bridge LLC, nominal resonant frequency near 150 kHz, and a provisional effective secondary voltage around 48.5 V including the illustrative rectification/connection drop.

The example uses the design thread already developed in Chapters 4–14 so the chapter can focus on end-to-end traceability rather than introducing a disconnected numerical problem.

Ro=482500=4.608 ΩR_o=\frac{48^2}{500}=4.608\ \Omega
Requirement GroupExample A Entry
Input380–420 VDC illustrative operating window
Output48 V, 500 W
TopologyHalf-bridge LLC
Nominal fr150 kHz
Turns-ratio thread33:8
Lm thread158.5 µH
Total Lr thread31.7 µH
Lr architectureHybrid example in Chapters 8/14
Thermal example50 °C ambient; thermally closed example near mid-80 °C hotspot
SafetyFinal end-product standard still required

4. Example A — Resonant Tank and Gain Solution

fr=12πLrCrf_r=\frac{1}{2\pi\sqrt{L_rC_r}}

Chapter 4 selected Lr ≈ 31.7 µH, Cr ≈ 35.5 nF, Ln = 5, and a 150 kHz nominal resonance. The tank candidate was then verified against required low-line boost gain and high-line frequency range.

TRACEABILITY POINT

Tank Values Are Not Independent Design Inputs

Lr, Cr, Ln, Q, turns ratio, and frequency window define one coupled operating map.

Changing the turns ratio or Lm later should automatically trigger regeneration of the gain curves.

5. Example A — Turns Ratio and Magnetizing Inductance

n=338=4.125n=\frac{33}{8}=4.125
Lm=5(31.7 μH)=158.5 μHL_m=5(31.7\ \mu\mathrm{H})=158.5\ \mu\mathrm{H}

Chapter 6 moved the continuous ratio into a practical 33:8 integer candidate. Chapter 7 then retained Ln = 5 as the nominal magnetizing-inductance tradeoff between boost gain, circulating current, and light-load ZVS support.

6. Example A — Hybrid Resonant Inductance and Controlled Leakage

Lr,total=Lr,ext+Llk,effL_{r,total}=L_{r,ext}+L_{lk,eff}
Lr,ext=31.7−11.7=20.0 μHL_{r,ext}=31.7-11.7=20.0\ \mu\mathrm{H}

The worked hybrid architecture intentionally assigns 11.7 µH of the total 31.7 µH to transformer leakage and leaves 20.0 µH external. A different product could choose fully external or fully integrated Lr without changing the traceability structure.

7. Example A — Core, Turns, Flux, and Gap

Bpk≈VP,flat4fsNPAeB_{pk}\approx\frac{V_{P,flat}}{4f_sN_PA_e}
Bpk,132k≈0.115 TB_{pk,132k}\approx0.115\ \mathrm{T}

Chapter 9 used 33 primary turns and an illustrative Ae ≈ 100 mm² candidate to show that the low-line, low-frequency corner could produce Bpk ≈ 0.115 T. The final core/material still has to be selected from vendor loss and hot-saturation data, then the gap/AL must be adjusted to realize 158.5 µH Lm.

8. Example A — Conductors and Winding Arrangement

ACu,min=IRMSJallowA_{Cu,min}=\frac{I_{RMS}}{J_{allow}}
FR=RACRDCF_R=\frac{R_{AC}}{R_{DC}}

Chapter 10 generated conductor candidates from RMS current, copper area, skin depth, proximity effect, litz/foil options, and physical window fill. Chapter 11 then changed the winding stack to satisfy leakage, CPS, and RAC simultaneously.

9. Example A — Loss, Thermal, Isolation, and EMI Closure

CPS≈ε0εrAovdC_{PS}\approx\varepsilon_0\varepsilon_r\frac{A_{ov}}{d}
Ptr=Pcore+PCu,P+PCu,S+Pterm+PotherP_{tr}=P_{core}+P_{Cu,P}+P_{Cu,S}+P_{term}+P_{other}
Thot=Tamb+PtrθthT_{hot}=T_{amb}+P_{tr}\theta_{th}
Ptr≈2.52 WP_{tr}\approx2.52\ \mathrm{W}
Thot≈85.7∘CT_{hot}\approx85.7^\circ\mathrm{C}

Chapters 11–13 then converted winding geometry into capacitance/EMI behavior, loss, temperature, insulation spacing, shield rules, and production safety tests. The 2.52 W / 85.7 °C thermal values were explicitly educational because core-loss density and thermal resistance were hypothetical screening inputs.

10. Example A — Manufacturing and Test Record

xspec=xnom±Δxx_{spec}=x_{nom}\pm\Delta x

Chapter 14 converted nominal parameters into an illustrative manufacturing record: 33:8 ratio, Lm target, hybrid leakage target, DCR/CPS limits, dielectric test plan, first-article checks, process capability, and change-control triggers.

  • Winding instructions and start/finish polarity.
  • Approved conductor and insulation materials.
  • Gap / AL requirement and assembly process.
  • Lm/leakage/ratio/DCR/CPS test definitions.
  • Dielectric/PD tests where required by certification.
  • Thermal and converter validation record.
  • Revision-controlled CAD/drawing/BOM package.

11. Example A — Final Traceability Summary

Design ResultExample A Traceability
TankLr ≈ 31.7 µH, Cr ≈ 35.5 nF, fr ≈ 150 kHz
Ratio33:8 → n = 4.125
Lm158.5 µH nominal thread
Lr architecture11.7 µH transformer leakage + 20.0 µH external example
Flux screenBpk ≈ 0.115 T at ~132 kHz with illustrative Ae=100 mm²
ConductorsHigh-frequency candidates from Chapter 10; final geometry must close RAC/window
CPS/EMIGeometry controlled; safety spacing and shield path finalized in Chapter 13
ThermalIllustrative Ptr ≈ 2.52 W / hotspot ≈ 85.7 °C
ProductionIllustrative Lm/Llk/DCR/CPS limits; final limits require real tolerance/capability study
Open itemsFinal ferrite/core part, product safety standard, supplier capability, certified test plan

ENGINEERING CAUTION

A Complete Example Should Show What Is Still Unknown

Hiding unselected ferrite material or unspecified safety standard behind a polished final number creates false certainty.

Automation should mark unresolved engineering dependencies explicitly.

12. Example B — A 250 W / 24 V Higher-Frequency LLC Starts from Different Priorities

EXAMPLE B

250 W / 24 V Higher-Frequency LLC

Use a second illustrative design to show that the same workflow does not force the same magnetic architecture. Assume a similar 380–420 VDC half-bridge bus, 24 V / 250 W output, a higher nominal resonance around 220 kHz, tighter height constraints, and a preference for external Lr so transformer coupling can be kept higher.

The following values are candidate-generation examples, not released component values.

Priority ChangeAutomation Consequence
Higher switching frequencyStricter ferrite and conductor AC-loss screening
Lower output voltage / high currentSecondary conductor and termination become stronger constraints
Lower profilePlanar / low-height core families score more favorably
External Lr preferenceTransformer leakage becomes an upper-limit constraint instead of a resonant target
Low CPS / EMI targetSpacing/shield geometry competes with coupling and planar overlap

13. Example B — Illustrative First-Pass Electrical Candidate

nB=415=8.20n_B=\frac{41}{5}=8.20
Lm,B=6(18 μH)=108 μHL_{m,B}=6(18\ \mu\mathrm{H})=108\ \mu\mathrm{H}
Cr,B≈26.9 nFC_{r,B}\approx26.9\ \mathrm{nF}

One illustrative normalized candidate might use Lr = 18 µH, Ln = 6, Lm = 108 µH, fr ≈ 220 kHz, and an integer ratio near 41:5. The automation should treat those as a candidate vector that still has to pass gain, ZVS, core-loss, winding, thermal, leakage, capacitance, and safety checks.

14. Example B — Why the Automation Should Generate Multiple Magnetic Candidates

Example B should not immediately become one transformer. It should branch into several magnetic candidates—for example a wound ferrite with litz primary, a planar/PCB structure, and a hybrid foil/litz winding—then compare them under the same hard constraints.

CandidateLikely StrengthLikely Failure Risk
Wound ferrite + litzFlexible winding geometry and insulationHeight / termination / layer count
Planar transformerLow profile, repeatable geometryCPS and proximity loss; limited integrated leakage freedom
Foil secondary + litz primaryStrong low-voltage current handlingFoil AC loss and edge/termination design
Two practical resonant-transformer examples showing different requirement sets branching into different magnetic candidate families before reconverging through a common feasibility, testing, and validation workflow.

Figure 15-2. Two practical resonant-transformer examples branching into different magnetic candidate families while preserving the same requirements-to-validation workflow.

15. Compare Example A and Example B

DimensionExample A — 500 W / 48 VExample B — 250 W / 24 V
Nominal fr~150 kHz~220 kHz illustrative
Ratio thread33:841:5 illustrative
Lr architectureHybrid exampleExternal-Lr preference
Lm thread158.5 µH108 µH illustrative
Secondary challengeHigh currentHigher current per output volt / low-profile constraint
Core priorityBalanced wound power transformerHigher-frequency / lower-profile screening
Automation lessonIntegrated leakage must be controlledLeakage may be minimized/bounded; CPS/height may dominate

16. Automation Begins with a Requirements Contract

Automation begins by converting every user input into a normalized requirements record:

𝐫=[Vin,Vo,Po,fs,η,T,Isolation,Size,…]\mathbf{r}=[V_{in},V_o,P_o,f_s,\eta,T,Isolation,Size,\ldots]
  • Electrical operating range and topology.
  • Required gain/frequency window.
  • Thermal/environmental limits.
  • Mechanical envelope and mounting.
  • Isolation / safety inputs.
  • Conductor / manufacturing preferences.
  • Optimization priorities.
  • Required deliverables and validation outputs.

EARLY ENGINEERING ACCESS

Get Your First Custom Magnetic Design for $49

Need a custom inductor, flyback transformer, or currently supported LLC/resonant transformer design for a real project? SolidMagnetics Early Engineering Access gives you a lower-cost way to evaluate the platform while it continues to expand.

STANDARD SINGLE DESIGN PRICE: $249   •   EARLY ACCESS PRICE: $49

Use coupon code EARLYACCESS. Your supported design package can include:

  • Candidate magnetic design output and recommended design direction
  • SolidWorks Reference CAD and STEP export where supported
  • Engineering drawings, BOM, winding, and design data where supported
  • A practical starting point for component matching, simulation, prototyping, or further development

Offer details: Limited to the first 10 qualified paid projects. One discounted project per customer. Expires February 12, 2027, or when all 10 uses are claimed, whichever comes first.

SolidMagnetics-generated designs are engineering starting points intended to accelerate development. Final component selection, manufacturability, tolerances, winding construction, insulation, creepage and clearance, thermal performance, regulatory requirements, and production suitability must be verified for the intended application.

17. Candidate Generation Converts Continuous Targets into Buildable Discrete Designs

𝐱=[Core,Material,NP,NS,Lm,Lr,Cr,Winding,Gap,…]\mathbf{x}=[Core,Material,N_P,N_S,L_m,L_r,C_r,Winding,Gap,\ldots]

The candidate vector contains both continuous variables and discrete buildable choices. Integer turns, catalog cores, real wire/litz/foil sizes, standard capacitor values, bobbins, insulation systems, and gap increments must enter the search before the design is declared buildable.

18. Feasibility Gates Must Run Before Optimization

Hard constraints should be represented as feasibility functions:

gi(𝐱,𝐫)≤0g_i(\mathbf{x},\mathbf{r})\le0

Required equality/contract relationships can be represented as:

hj(𝐱,𝐫)=0h_j(\mathbf{x},\mathbf{r})=0
  • Gain/frequency window satisfied.
  • Flux/saturation/core-loss valid.
  • Lm and Lr architecture realizable.
  • Window fill and winding manufacturable.
  • RAC/copper loss and hotspot acceptable.
  • CPS/EMI target acceptable.
  • Safety spacing and insulation valid.
  • Mechanical envelope valid.
  • Production tolerances measurable and achievable.

SOLIDMAG ENGINEERING INSIGHT

Optimization Must Never Make an Infeasible Candidate Look Good

Size, cost, efficiency, temperature, and EMI weights should rank only candidates that already pass every hard constraint.

This separation is critical for trustworthy automation.

19. Optimization Should Rank Only Feasible Candidates

S(𝐱)=∑k=1Nowkf^k(𝐱)S(\mathbf{x})=\sum_{k=1}^{N_o}w_k\hat f_k(\mathbf{x})
∑k=1Nowk=1\sum_{k=1}^{N_o}w_k=1
f^k=fk−fk,minfk,max−fk,min\hat f_k=\frac{f_k-f_{k,min}}{f_{k,max}-f_{k,min}}

A normalized weighted score can rank size, efficiency, cost, thermal margin, EMI, manufacturability, or other objectives. The score should be accompanied by the raw engineering values so users can see why one candidate ranks above another.

20. Tolerance Propagation Turns Nominal Designs into Production Designs

First-order sensitivity can quickly identify which tolerances matter most:

Δy≈∑i∂y∂xiΔxi\Delta y\approx\sum_i\frac{\partial y}{\partial x_i}\Delta x_i

For LLC magnetics, important tolerances can include Lm, transformer leakage, resonant capacitor, turns ratio, DCR, ferrite AL/gap, conductor placement, CPS, ambient temperature, and controller frequency limits.

21. Monte Carlo Analysis Can Estimate Multi-Parameter Production Yield

Ppass=Pr⁡[gi(𝐱)≤0 ∀i]P_{pass}=\Pr\left[g_i(\mathbf{x})\le0\ \forall i\right]
YMC=NfeasibleNsamples×100%Y_{MC}=\frac{N_{feasible}}{N_{samples}}\times100\%

Monte Carlo or another statistical tolerance method can estimate how often randomly sampled production combinations remain feasible. It is most useful after the deterministic model and individual tolerance ranges are already trustworthy.

22. Every Automated Design Should Be Versioned and Reproducible

IDdesign=Hash(𝐫,𝐱,vcalc,vdata)ID_{design}=Hash(\mathbf{r},\mathbf{x},v_{calc},v_{data})

A reproducible design should retain the calculation-code version, core/material database revision, CAD-template revision, standard/reference versions, and user inputs. A redesign made six months later should be explainable even if databases or code have changed.

23. CAD Automation Should Consume a Locked Engineering Contract

CAD should consume a locked engineering contract rather than recompute electrical design independently. For a transformer template that contract may include:

  • Core/bobbin family and dimensions.
  • NP, NS, auxiliary turns and winding sections.
  • Conductor dimensions / litz bundle / foil thickness and width.
  • Layer pitch, margins, insulation thickness, interleaving, separation.
  • Gap / AL-related mechanical features.
  • Pin assignments, lead routing, winding start/finish.
  • Shield geometry and insulation barriers.
  • Suppression/activation of unused layers or sections.

ENGINEERING CAUTION

CAD Must Not Quietly Repair an Infeasible Electrical Design

If the specified winding cannot fit or violates a clearance, CAD generation should fail with a traceable engineering reason.

Changing turns, conductor, or margins inside the CAD worker would break design traceability.

24. Manufacturing Outputs Should Be Generated from the Same Design Record

The same design record can generate downstream manufacturing outputs such as:

  • SolidWorks part/assembly or other CAD source.
  • STEP model.
  • PDF manufacturing drawing.
  • BOM CSV.
  • Winding instruction / layer table.
  • Critical dimensions and tolerances.
  • Electrical specification table.
  • Production test limits and terminal conditions.
  • Validation / traceability report.
  • ZIP manufacturing package.
Automated resonant transformer output package showing one locked design record generating CAD, STEP, manufacturing drawing, BOM, winding instructions, specification sheet, production tests, and traceability report.

Figure 15-3. Automated resonant-transformer output package generated from one locked design record: CAD, STEP, drawing, BOM, winding instructions, specification, production tests, and traceability report.

25. Production Test Limits Should Be Generated from the Same Tolerance Model

Production tests should be generated from the same tolerance model rather than typed independently into a test document. This keeps the Lm, leakage, DCR, CPS, ratio, and dielectric limits synchronized with the design revision.

xspec=xnom±Δxx_{spec}=x_{nom}\pm\Delta x
Rtrace(reqi,outj)∈{pass,fail,not checked}R_{trace}(req_i,out_j)\in\{pass,fail,not\ checked\}
RequirementCalculation / ModelCAD / Manufacturing OutputValidation
Required LmGain/ZVS modelGap/AL + turns + spec tableLCR test
Required LrTank modelWinding leakage geometry / external LrLeakage + resonant-frequency test
Flux marginVolt-second/core modelCore/turns drawingWaveform / saturation validation
Copper lossRAC modelConductor + winding stackDCR/RAC/temperature
CPS / EMIElectrostatic modelSpacing/shield geometryCapacitance + EMI test
IsolationSafety requirementsBarrier / creepage / clearance geometryDielectric / certification test

27. A Worker Pipeline Can Separate Web Requests from CAD Generation

A practical implementation can separate the public web/API calculation process from slower or licensed CAD generation. A queue/worker architecture allows calculation, status reporting, CAD generation, export, packaging, and cloud upload to occur as traceable stages rather than one blocking web request.

  • API validates and normalizes user requirements.
  • Core calculation service generates/ranks feasible designs.
  • Job record stores locked design contract and versions.
  • Worker opens the CAD template and writes only approved design variables.
  • Worker exports CAD/drawing/BOM/manufacturing files.
  • Package is validated, zipped, and uploaded to controlled storage.
  • User receives the result associated with the original design ID.
SolidMagnetics automation pipeline showing WordPress design requirements flowing through the API, core calculations, job queue, CAD worker, validation, packaging, secure storage, and controlled customer download.

Figure 15-4. SolidMagnetics-style API/Core/Worker automation pipeline from web requirements through calculations, job contract, CAD generation, exports, validation, packaging, and controlled download.

28. Human Review Belongs at the Boundaries AI and Equations Cannot Prove

Human engineering review belongs wherever the model’s authority ends. Examples include selecting the governing product safety standard, approving a novel insulation system, judging vendor data outside its stated range, accepting a new material substitution, resolving unexpected EMI behavior, or interpreting prototype discrepancies.

SOLIDMAG ENGINEERING INSIGHT

Automation Is Strongest When It Knows When to Stop

A trustworthy system should return ‘not validated’ or request review rather than manufacture confidence from missing data.

Explicit uncertainty is an engineering feature.

29. Prototype Measurements Should Feed Back into the Design Model

Prototype and production measurements should update model calibration without erasing the original design assumptions. Store measured Lm, Llk, DCR, CPS, thermal resistance, core/winding temperatures, resonant frequency, and EMI results against the design ID.

  • Compare predicted vs. measured values.
  • Identify systematic model bias.
  • Update calibrated correction factors or material/process distributions.
  • Re-run historical designs only under a new calculation/data version.
  • Preserve old results for auditability.

30. What Automation Can and Cannot Replace

Automation Can Do WellAutomation Cannot Prove by Itself
Repeat equations consistentlyProduct-specific regulatory approval
Search large core/material/conductor spacesValidity of missing/incorrect manufacturer data
Run tolerance and optimization sweepsUnexpected field behavior outside the model
Generate deterministic CAD from a locked contractManufacturing workmanship without inspection
Generate drawings/BOM/test limitsReal thermal/EMI behavior without prototype correlation
Maintain traceability/versioningEngineering responsibility for the released product
  1. Collect and normalize user requirements.
  2. Select topology/model convention and validate required inputs.
  3. Solve tank/gain design and generate a normalized operating map.
  4. Generate integer turns-ratio candidates.
  5. Generate Lm/Ln candidates and check gain/current/ZVS.
  6. Allocate external/integrated/hybrid Lr.
  7. Screen core/material/turns/gap candidates from flux, loss, window, and Lm.
  8. Generate conductor candidates and winding arrangements.
  9. Calculate leakage, CPS, RAC, loss, thermal, safety, and mechanical feasibility.
  10. Reject every candidate failing a hard constraint.
  11. Rank feasible candidates using transparent optimization objectives.
  12. Run tolerance propagation / production-yield analysis.
  13. Lock the selected design contract and version record.
  14. Generate CAD, drawing, STEP, BOM, winding specification, and production tests.
  15. Validate output files against the locked contract.
  16. Prototype and measure converter operation, thermal, EMI, isolation, and production parameters.
  17. Correlate measurements to the model and issue the validated design revision.
Complete automated resonant-transformer workflow from requirements through calculations, candidate search, feasibility, optimization, tolerance analysis, magnetic geometry, CAD and manufacturing outputs, prototype validation, and design feedback.

Figure 15-5. Complete automated resonant-transformer workflow from requirements through calculations, candidate search, feasibility, optimization, tolerance analysis, CAD/manufacturing package, prototype validation, and feedback.

32. Chapter 15 Engineering Checklist

  • All equations use one documented LLC convention.
  • User inputs are normalized and versioned.
  • Candidate designs are buildable discrete combinations, not only continuous math solutions.
  • Hard feasibility gates run before optimization.
  • Turns ratio, Lm, Lr, core, winding, CPS, loss, thermal, safety, and manufacturing constraints are all represented.
  • Tolerance propagation is separate from nominal feasibility.
  • CAD consumes a locked engineering contract.
  • CAD generation cannot silently change engineering values.
  • BOM, drawing, winding spec, and production-test limits come from the same design record.
  • Every output traces back to requirements and model/data versions.
  • Prototype measurements are stored against the design ID.
  • Model corrections create new versions rather than rewriting history.
  • Human review gates are explicit where standards/data/model validity is unresolved.
  • The final manufacturing package can be reproduced from the saved design record.

ULTIMATE GUIDE TAKEAWAY

The Deliverable Is the Engineering Chain, Not Just a Transformer Calculation

A single answer for turns or core size is easy to reproduce. The difficult and valuable work is preserving feasibility, geometry, tolerance, manufacturability, testability, and traceability all the way to a buildable package.

That complete chain is the foundation of trustworthy magnetic-design automation.

33. Conclusion — The Value Is the Complete Engineering Chain

The resonant converter transformer sits at the intersection of converter control, resonant gain, magnetics, high-frequency conductor physics, electric-field coupling, thermal design, safety insulation, EMI, and manufacturing process capability. No one equation determines the best design.

A complete workflow turns those coupled disciplines into a sequence of explicit engineering contracts: requirements define the operating window; the tank defines gain and frequency; turns ratio and Lm define transformer behavior; Lr architecture and winding geometry define leakage; core and turns define flux; conductor and stack define RAC and CPS; loss and insulation define thermal/safety feasibility; manufacturing tests define whether production units remain the same design.

Automation becomes valuable when it preserves that chain consistently, explores more candidates than a manual workflow can reasonably compare, and produces repeatable engineering outputs without hiding unresolved assumptions. That is the design philosophy behind the SolidMagnetics resonant-transformer workflow.

Technical References for This Chapter

The automated design concepts in this chapter build on established manufacturer design sequences and current digital magnetic-design tools. They demonstrate that many magnetics calculations can already be digitized; the additional challenge is integrating those calculations with feasibility, CAD, manufacturing, validation, and traceability.

RESONANT CONVERTER TRANSFORMER DESIGN

Ready to Design a Resonant Converter Transformer?

Enter your resonant-converter requirements and begin a SolidMagnetics transformer design workflow built around the electrical, magnetic, winding, thermal, mechanical, and manufacturing constraints that shape a practical LLC or related resonant transformer.

Use the design interface to define the converter operating range, transformer requirements, resonant and magnetizing inductance targets, winding priorities, isolation needs, thermal limits, physical constraints, and optimization goals.

Return to the Ultimate Guide to Resonant Converter Transformer Design

READY TO APPLY THIS?

Turn Your Requirements Into a Real Magnetic Design

If you are working on a real inductor, flyback transformer, or supported LLC/resonant transformer project, SolidMagnetics can help you move faster from electrical requirements to calculated magnetic geometry and engineering output.

FOUNDING EARLY ENGINEERING ACCESS: $249   →   $49

Use coupon code EARLYACCESS for the Single Design package. This offer is intended for engineers who want to evaluate the current SolidMagnetics workflow and provide practical feedback that helps improve the platform.

What the Current Package Can Include

  • Requirements and feasibility review
  • Candidate design comparison and recommended design
  • Electrical, magnetic, loss, and thermal calculations
  • SolidWorks Reference CAD and STEP files where supported
  • Drawings, BOM, winding, and engineering data where supported
  • A basis for comparing custom geometry with commercial core and bobbin options

Early Access Offer Details

  • Single Design standard price: $249
  • Early Engineering Access price: $49
  • Coupon code: EARLYACCESS
  • Limited to 10 total qualified paid projects
  • One discounted project per customer
  • Expires February 12, 2027, or when all 10 uses are claimed
  • Brief post-delivery feedback is requested

The standard package provides a Reference CAD representation of the generated design rather than the complete underlying SolidMagnetics parametric automation structure. Fully parametric engineering CAD may be available separately for qualifying advanced or Enterprise projects.

Early Access calculations, CAD, drawings, and related deliverables are intended to accelerate engineering evaluation and prototype development. Final mechanical, electrical, thermal, insulation, regulatory, manufacturing, and production validation remains the responsibility of the customer and their engineering team.

ABOUT THE AUTHOR

Stan Gibson

Electrical Engineer & Founder, SolidMagnetics

Stan Gibson is an electrical engineer and founder of SolidMagnetics, an engineering platform focused on magnetic-component design automation. His work includes power electronics, inductor and transformer design, magnetic-core selection, winding design, thermal analysis, and manufacturable CAD development. Through SolidMagnetics, he develops technical guides, calculators, and automated design tools intended to help engineers move from electrical requirements to practical magnetic-component designs.

View Full Author Profile