Chapter 3 established the LLC operating map: series resonance, below- and above-resonance regulation, the inductive region required for reliable primary-side ZVS, and the load-dependent boundaries that must be respected. Chapter 4 now turns that operating picture into a resonant-tank design by selecting and relating the resonant inductance Lr, resonant capacitance Cr, transformer magnetizing inductance Lm, quality factor Q, inductance ratio Ln, normalized frequency, and voltage gain.
The objective is not to produce one mathematically valid set of Lr, Lm, and Cr values. It is to create a tank that reaches the required gain across line and load, stays inside the intended inductive operating region, keeps switching frequency within practical limits, provides acceptable circulating current and ZVS margin, and can ultimately be realized with a physical transformer and repeatable manufacturing tolerances.
← Previous Chapter
Chapter 3 — LLC Resonant Operation, Soft Switching, and Operating Regions
In This Chapter — Click to Expand
Table of Contents
DESIGN ASSUMPTION
One Defined First-Harmonic Convention
This chapter uses a primary-referred first-harmonic approximation with turns ratio n = NP/NS, equivalent AC load Rac, characteristic impedance Zr = √(Lr/Cr), inductance ratio Ln = Lm/Lr, and quality factor Q = Zr/Rac.
Some LLC references define the reciprocal inductance ratio or reciprocal quality factor. The equations in this chapter are internally consistent only when these definitions are used together.
1. Resonant Tank Design Is a Coupled Optimization Problem
The resonant tank determines far more than nominal resonant frequency. The same component values also establish the gain curve, resonant current, magnetizing current, frequency-control range, and soft-switching margin. Changing one parameter generally moves several design constraints at once.
| Tank Variable | Primary Influence | Coupled Consequence |
|---|---|---|
| Lr | Series resonant inductance and characteristic impedance | Can be external, transformer leakage, or hybrid; changes resonant current and gain curve. |
| Cr | Series resonance and characteristic impedance | Voltage stress, RMS current, physical capacitor technology, and tolerance matter. |
| Lm | Magnetizing branch and lower characteristic resonance | Changes gain capability, circulating current, and ZVS-supporting current. |
| Ln = Lm/Lr | Normalized separation of Lm and Lr | Shapes boost gain, frequency span, magnetizing current, and characteristic-frequency separation. |
| Q = Zr/Rac | Load-normalized damping under this chapter’s convention | Higher Q corresponds to heavier loading; changes peak gain and usable frequency range. |
| fr | Series resonant reference frequency | Sets the absolute frequency scale for the entire design. |
SOLIDMAG ENGINEERING INSIGHT
The Tank Is a Design Space, Not Three Independent Components
Selecting Lr, Cr, and Lm independently often produces a converter that satisfies one equation but fails gain range, soft-switching margin, or practical frequency limits.
A better design process selects normalized behavior first, then converts the selected normalized ratios into physical component values.
2. Define the LLC Reference Quantities
The series resonant frequency is:
The characteristic impedance of the Lr–Cr pair is:
Normalized switching frequency is:
The inductance ratio used throughout this guide is:

Figure 4-1. Primary-referred LLC resonant tank showing Cr, Lr, magnetizing branch Lm, ideal transformer ratio, reflected AC load Rac, and the normalized design quantities fr, Zr, Fn, Ln, and Q.
3. Convert the DC Load to the Primary-Referred AC Load
The rectifier and DC load are converted into an equivalent AC resistance so the resonant network can be analyzed as a sinusoidal first-harmonic circuit. For a resistive DC output load:
Define the primary-to-secondary turns ratio as:
For the common full-wave FHA load transformation used in LLC design, the primary-referred AC load is:
ENGINEERING CAUTION
The Rac Conversion Depends on the Rectifier and Modeling Convention
The 8/π² relationship is the common FHA transformation for the stated full-wave output model. Different rectifier arrangements, voltage-doubler structures, current-doubler structures, multi-output systems, or alternative normalization conventions can require a different effective load transformation.
Use the load model that matches the actual secondary topology before calculating Q.
4. Lock the Quality-Factor Convention Before Using Gain Equations
This guide defines quality factor as:
Under this convention, heavier load produces a smaller Rac and therefore a larger Q. Light load produces a larger Rac and smaller Q; the no-load FHA limit approaches Q = 0.
Some references instead define the reciprocal quantity. The inductance-ratio notation can also differ. A common reciprocal inductance definition is:
ENGINEERING CAUTION
Do Not Mix Gain Equations from Different Q or Inductance-Ratio Conventions
If one application note uses Q = Zr/Rac and another uses Q = Rac/Zr, identical numerical values represent opposite loading conditions.
Likewise, λ = Lr/Lm is the reciprocal of Ln = Lm/Lr. Always translate the definitions before copying a gain equation, chart, or recommended ratio.
5. The First-Harmonic LLC Gain Equation
Using the definitions above, a standard first-harmonic voltage-gain magnitude can be written in terms of normalized frequency Fn, inductance ratio Ln, and quality factor Q as:
The equation shows why tank design is coupled. Fn sets where the converter operates relative to resonance. Ln controls how strongly the magnetizing branch reshapes the curve. Q changes with reflected load and sets the damping of the network.
ENGINEERING CAUTION
First-Harmonic Gain Is a Design Model, Not a Complete Switching Simulation
FHA is strongest near the intended resonant operating region, where tank current is approximately sinusoidal. Accuracy can degrade when operation moves far from resonance, during burst, startup, overload, or when parasitic and nonlinear effects become comparable to intentional tank elements.
Use FHA for design iteration and gain mapping, then verify important corners with switching simulation and hardware.

Figure 4-2. LLC gain families versus normalized frequency showing the effects of changing Q at fixed Ln and changing Ln at fixed Q.
6. Why the Gain Is Unity at Series Resonance
At the series resonant frequency Fn = 1, the gain equation reduces to:
That load-independent unity-gain point is one of the most useful LLC design references. The transformer ratio can be selected so that a preferred nominal operating condition lies near this point, allowing the converter to move below resonance for additional gain or above resonance for reduced gain.
The actual DC input-to-output ratio still depends on whether the primary uses a half bridge or full bridge, the turns-ratio convention, the rectifier topology, diode or synchronous-rectifier drops, and losses. Chapter 6 develops the physical turns-ratio design after the operating window is established.
7. Translate Converter Requirements into a Required Gain Window
Before choosing component values, determine the minimum and maximum tank gain required by the complete input/output operating range. That gain window must include tolerances and losses rather than only nominal voltages.
- Minimum input voltage with maximum required output voltage.
- Maximum input voltage with minimum required output voltage.
- Rectifier or synchronous-rectifier conduction loss.
- Transformer turns-ratio tolerance created by integer turns.
- Resonant-component tolerance.
- Magnetizing-inductance tolerance.
- Controller minimum and maximum switching frequency.
- Efficiency and wiring loss where they materially change the required conversion ratio.
SOLIDMAG ENGINEERING INSIGHT
The Gain Window Should Be Defined Before the Tank Values
Lr, Cr, and Lm should be selected to satisfy a required gain window—not the other way around.
If the first tank candidate cannot reach the required maximum gain while remaining inductive, change Ln, Q, turns ratio, or topology assumptions rather than forcing the frequency below a safe boundary.
8. Select the Resonant Frequency
The resonant frequency establishes the absolute frequency scale of the converter. It is commonly selected near a desired full-load operating point, but the optimum value depends on semiconductor technology, core material, winding construction, efficiency, EMI, controller capability, and physical size.
| Higher fr Tends Toward | Lower fr Tends Toward |
|---|---|
| Smaller magnetics and capacitors | Larger magnetics and resonant capacitor |
| Higher core and winding AC loss sensitivity | Lower high-frequency loss |
| More stringent PCB and parasitic control | More relaxed parasitic timing |
| Potentially higher power density | Potentially easier thermal margin |
| Stronger impact of device capacitance and dead time | Longer switching intervals and potentially larger energy per cycle |
Do not choose fr simply because a controller supports it. Choose a frequency that the selected magnetic material, winding technology, semiconductor technology, and thermal design can sustain at the actual flux and current levels.
9. Select the Inductance Ratio Ln
Ln is one of the primary shape parameters of the LLC gain curve. Lower Ln means smaller magnetizing inductance relative to Lr; higher Ln means larger magnetizing inductance.
| Lower Ln | Higher Ln |
|---|---|
| Higher magnetizing current | Lower magnetizing current |
| Typically more available boost gain | Typically less available boost gain |
| Potentially stronger ZVS-supporting current | Potentially less commutation current at light load |
| Higher circulating/conduction loss | Lower circulating loss near nominal operation |
| Lower lower-characteristic frequency separation behavior | Greater separation between fm and fr |
The correct Ln is generally the largest value that still provides the required maximum gain and soft-switching margin across the specified operating window, because increasing Lm tends to reduce unnecessary magnetizing current.
ENGINEERING CAUTION
Do Not Optimize Ln Only for Maximum Gain
Very low Ln may make the gain curve attractive but can impose excessive magnetizing current, copper loss, MOSFET RMS current, and transformer thermal stress.
Tank gain and magnetic loss must be evaluated together.
10. Select the Full-Load Quality Factor Q
At the maximum intended load, Rac is smallest and Q is largest under this chapter’s convention. A first-pass Q target establishes the characteristic impedance needed for the desired loaded gain behavior.
Rearranging the Q definition gives:
Lower Q reduces Zr relative to the reflected load and generally changes the resonant current and gain shape. Higher Q increases Zr and changes the loaded peak-gain behavior. There is no universal optimum Q; it must be selected with the required gain range, current stress, and frequency window.
SOLIDMAG ENGINEERING INSIGHT
Q Is a Load-Dependent Design Coordinate
Q is not a fixed property of the tank when the load changes because Rac changes with load.
Design the tank using the relevant maximum-load Q, then generate gain curves for the lighter-load Q values rather than assuming one Q describes the whole converter.
11. Convert fr, Q, Rac, and Ln into Lr, Cr, and Lm
Once fr, Q, Rac, and Ln have been selected, the physical resonant values can be calculated directly. First determine Zr from Q and Rac, then:
The lower characteristic frequency then follows from:
or in normalized form:
ENGINEERING CAUTION
Calculated Tank Values Are Not Yet Real Component Values
The calculated Lr, Lm, and Cr are ideal design targets. Standard capacitor values, transformer tolerances, leakage distribution, temperature, frequency dependence, and manufacturing variation will shift the realized tank.
Always re-run the gain and operating-region analysis with the values that can actually be built.
12. Establish the Minimum and Maximum Switching Frequencies
The selected gain curves provide minimum and maximum normalized switching frequencies. Convert them back to physical frequency using:
The controller, gate driver, transformer, resonant capacitor, semiconductors, EMI network, and thermal design must all support this complete frequency range.
| Frequency Limit | Questions to Verify |
|---|---|
| Minimum switching frequency | Is the converter still inductive? Is peak gain adequate? Are resonant current and flux acceptable? |
| Near resonance | Does the nominal design achieve high efficiency and acceptable current? |
| Maximum switching frequency | Are switching loss, winding AC loss, core loss, gate-drive loss, and controller timing acceptable? |
| Burst / skip behavior | Does the effective pulse frequency create audible, transient, or ZVS problems? |
EARLY ENGINEERING ACCESS
Get Your First Custom Magnetic Design for $49
Need a custom inductor, flyback transformer, or currently supported LLC/resonant transformer design for a real project? SolidMagnetics Early Engineering Access gives you a lower-cost way to evaluate the platform while it continues to expand.
STANDARD SINGLE DESIGN PRICE: $249 • EARLY ACCESS PRICE: $49
Use coupon code EARLYACCESS. Your supported design package can include:
- Candidate magnetic design output and recommended design direction
- SolidWorks Reference CAD and STEP export where supported
- Engineering drawings, BOM, winding, and design data where supported
- A practical starting point for component matching, simulation, prototyping, or further development
Offer details: Limited to the first 10 qualified paid projects. One discounted project per customer. Expires February 12, 2027, or when all 10 uses are claimed, whichever comes first.
SolidMagnetics-generated designs are engineering starting points intended to accelerate development. Final component selection, manufacturability, tolerances, winding construction, insulation, creepage and clearance, thermal performance, regulatory requirements, and production suitability must be verified for the intended application.
13. Verify Peak Gain and the Inductive Operating Boundary
For a given Ln and maximum-load Q, the resonant gain curve generally reaches a peak below the series resonant frequency. The peak can be found numerically from the condition:
The selected tank should satisfy the maximum required gain with margin:
In practical LLC design, the minimum commanded switching frequency should also remain on the intended inductive side of the load-dependent operating boundary. The exact margin should be verified with the same gain/impedance model and then with switching simulation.
ENGINEERING CAUTION
Do Not Design Exactly at the Peak-Gain Boundary
Component tolerance, temperature, transformer leakage, device capacitance, and load variation can move the real boundary.
A production design should retain margin between the lowest intended switching frequency and the onset of unacceptable capacitive or hard-switching operation.

Figure 4-3. Maximum-load LLC gain curve showing required maximum gain, peak gain, selected minimum normalized frequency, series resonance, and the reserved margin to the undesirable operating boundary.
14. Evaluate Parameter Tolerance Before Choosing Standard Values
The resonant frequency itself shifts with Lr and Cr tolerance. A first-order small-variation estimate is:
Lm tolerance also changes Ln and the lower characteristic frequency. If transformer leakage supplies Lr, the leakage tolerance can be driven by winding geometry, insulation thickness, bobbin dimensions, lead routing, and assembly.
- Minimum and maximum Cr over initial tolerance, bias, temperature, and aging where applicable.
- Minimum and maximum Lr including external-inductor or transformer-leakage tolerance.
- Minimum and maximum Lm including core permeability, gap, assembly, and measurement tolerance.
- Turns-ratio integer rounding and production turn-count variation.
- Maximum-load and light-load Rac / Q values.
- Controller frequency tolerance and minimum/maximum command limits.

Figure 4-4. LLC tank tolerance cloud showing how Lr, Cr, Lm, turns ratio, and load tolerance move resonant frequency, gain curves, and the minimum safe switching frequency.
15. Decide Whether Lr Is External, Integrated, or Hybrid
The electrical tank calculation produces a target Lr. The next architectural question is where that inductance physically resides.
| Lr Architecture | Advantages | Design Consequences |
|---|---|---|
| External resonant inductor | Independent component tolerance and tuning; transformer can emphasize coupling | Adds core, copper, volume, cost, and loss. |
| Transformer-integrated leakage | Reduces magnetic component count and can improve power density | Leakage becomes a controlled production parameter tied directly to winding geometry. |
| Hybrid | Allows transformer leakage to provide part of Lr while an external inductor supplies the remainder | Provides tuning flexibility but requires tolerance allocation between two inductive contributions. |
SOLIDMAG ENGINEERING INSIGHT
The Lr Architecture Must Be Chosen Before the Final Winding Stack
A transformer designed for minimum leakage and a transformer designed to produce a controlled resonant inductance are physically different products.
Do not finalize interleaving, winding separation, insulation thickness, or section order until the Lr architecture is known.
16. Worked Example — Build a First-Pass LLC Tank
WORKED DESIGN EXAMPLE
First-Pass 500 W / 48 V LLC Tank
This normalized educational example assumes the transformer turns ratio has already been provisionally selected as n = 4, the desired series resonant frequency is 150 kHz, the full-load quality-factor target is Q = 0.5 using this chapter’s convention, and Ln = 5.
The example demonstrates how fr, Q, Rac, and Ln become Lr, Cr, and Lm. It is not a released converter design and does not yet include device drops, isolation construction, leakage implementation, core selection, or thermal validation.
| Parameter | Illustrative Value |
|---|---|
| Output voltage | 48 V |
| Output power | 500 W |
| Provisional NP/NS ratio, n | 4 |
| Target fr | 150 kHz |
| Target Q at full load | 0.5 |
| Target Ln | 5 |
Step 1 — Calculate the DC load resistance:
Step 2 — Reflect the FHA AC load to the primary:
Step 3 — Calculate the characteristic impedance:
Step 4 — Calculate the resonant inductance:
Step 5 — Calculate the resonant capacitance:
Step 6 — Calculate the magnetizing inductance:
Using the gain equation with Ln = 5 and Q = 0.5, the illustrative gain is approximately 1.09 at Fn = 0.8, 1.00 at Fn = 1.0, and 0.93 at Fn = 1.2. Those points show the expected boost-below-resonance and buck-above-resonance behavior, but a complete design would calculate the entire gain and phase family over all required loads.
| Fn | Switching Frequency for fr = 150 kHz | Illustrative FHA Gain |
|---|---|---|
| 0.80 | 120 kHz | ≈ 1.09 |
| 1.00 | 150 kHz | 1.00 |
| 1.20 | 180 kHz | ≈ 0.93 |
ENGINEERING CAUTION
Do Not Treat the Example Turns Ratio as Final
The provisional n = 4 was used only to demonstrate the reflected-load and tank calculations.
Chapter 6 will select the physical integer turns ratio from the actual input/output gain window, bridge structure, rectifier topology, voltage drops, and available frequency range.
17. Recalculate the Gain Curve with Real Component Values
Real component values will rarely equal the calculated targets exactly. After choosing a realizable Cr value and a realizable Lr/Lm implementation, recalculate:
- Actual fr from the realized Lr and Cr.
- Actual Zr from the realized Lr and Cr.
- Actual Ln from realized Lm/Lr.
- Maximum-load and light-load Q.
- Maximum available gain.
- Minimum and maximum required switching frequency.
- Input-impedance phase and inductive margin.
- Primary resonant and magnetizing current.
- ZVS commutation margin.
SOLIDMAG ENGINEERING INSIGHT
Standard Values Belong Inside the Iteration Loop
Selecting a standard capacitor or manufacturable leakage target is not a final clerical step. It changes the tank equations.
Every standard-value or manufacturing adjustment should be fed back through the gain and operating-corner analysis before the design is frozen.
18. Tank Design Sensitivity and Tradeoffs
| Design Change | Likely Benefit | Likely Cost / Risk |
|---|---|---|
| Increase fr | Smaller magnetics / capacitor potential | Higher switching, core, proximity, and parasitic sensitivity. |
| Decrease fr | Lower high-frequency loss sensitivity | Larger magnetic and resonant components. |
| Decrease Ln | More boost gain and magnetizing current for ZVS | Higher circulating current and conduction loss. |
| Increase Ln | Lower magnetizing current | Reduced maximum gain and potentially weaker light-load ZVS margin. |
| Increase Q under this convention | Changes loaded gain curve / characteristic impedance | Can reduce usable boost region depending on operating point. |
| Increase transformer leakage contribution to Lr | Fewer separate magnetic components | Harder winding-tolerance control; often changes interwinding capacitance and AC loss. |
| Increase interleaving | Lower leakage / AC loss in some structures | May raise primary-secondary capacitance and conflict with an integrated-Lr target. |
The correct tank is therefore not the one with the largest gain, smallest magnetizing current, lowest leakage, or highest resonant frequency. It is the tank whose complete electrical and physical implementation satisfies the system objectives together.
19. Recommended Resonant-Tank Design Workflow
A practical Chapter 4 tank-design loop is:
- Define the required minimum and maximum converter gain.
- Select a provisional transformer ratio and secondary rectifier model.
- Convert output load to primary-referred Rac.
- Choose an initial resonant frequency fr.
- Choose an initial Ln based on required gain and acceptable magnetizing current.
- Choose maximum-load Q and calculate Zr.
- Calculate Lr, Cr, and Lm.
- Generate gain curves across the required load/Q range.
- Find the minimum safe normalized frequency and verify peak gain margin.
- Find the maximum normalized frequency needed for minimum gain.
- Convert normalized frequencies to physical switching-frequency limits.
- Check resonant current, magnetizing current, ZVS margin, and component stress.
- Choose external, integrated, or hybrid Lr implementation.
- Apply tolerances and realizable standard/component values.
- Recalculate the complete gain and phase map.
- Iterate until electrical, magnetic, thermal, control, and manufacturability constraints all agree.

Figure 4-5. End-to-end LLC resonant-tank design loop from required gain and reflected load through fr, Q, Ln, Zr, Lr, Cr, Lm, gain curves, frequency limits, tolerance, physical implementation, and iteration.
20. Design Handoff to Transformer Requirements
At the end of Chapter 4, the converter design should provide a traceable tank and gain specification that Chapter 5 can convert into transformer-level requirements.
- Target fr and acceptable resonant-frequency range.
- Target Lr and its external / integrated / hybrid allocation.
- Target Cr and capacitor tolerance / stress requirements.
- Target Lm and allowable tolerance.
- Target Ln.
- Maximum-load and representative light-load Q values.
- Required minimum and maximum gain.
- Required minimum and maximum switching frequency.
- Minimum inductive/ZVS operating margin.
- Primary resonant-current and magnetizing-current envelope.
- Secondary topology and provisional turns ratio used by the FHA model.
- Parameter tolerances that must be preserved by the transformer design.
21. Chapter 4 Engineering Checklist
- Are Ln, Q, turns ratio, and Rac definitions explicitly stated?
- Is the required gain window known before tank values are selected?
- Does the selected Ln provide adequate gain without excessive magnetizing current?
- Does the maximum-load Q produce an acceptable gain and current characteristic?
- Are fr and the full physical switching-frequency range acceptable for the magnetic and semiconductor technologies?
- Does peak gain exceed the required maximum gain with margin?
- Does the minimum commanded frequency remain inside the intended inductive region?
- Have Lr, Cr, and Lm been recalculated after choosing realizable values?
- Have component and transformer tolerances been applied?
- Has the Lr architecture—external, integrated, or hybrid—been selected?
- Have light-load and no-load gain curves been reviewed?
- Have resonant current and magnetizing current been checked, not just gain?
- Have ZVS and startup/overload conditions been verified separately from nominal FHA gain?
CHAPTER TAKEAWAY
Normalize First, Build Second
The most reliable LLC tank workflow chooses the normalized gain behavior—required gain, Ln, Q, and Fn range—before locking physical Lr, Cr, and Lm values.
Once the normalized design works, the physical component values can be calculated, made manufacturable, and fed back through the same gain model.
22. Conclusion — The Tank Values Are a Starting Point for the Physical Transformer
LLC resonant-tank design is the bridge between converter requirements and transformer requirements. The tank values determine the gain curve and frequency window, but they also become physical targets that the transformer and resonant components must realize.
Lr and Cr establish the series resonance and characteristic impedance. Lm creates the second inductive degree of freedom. Ln shapes gain and circulating current. Q connects the tank to load. The resulting gain family determines where the controller must operate to regulate the converter.
The next chapter converts those electrical targets into a formal transformer operating window so that turns ratio, magnetizing inductance, leakage allocation, core selection, winding current, isolation, loss, and thermal design can be evaluated against the same converter requirements.
Technical References for This Chapter
The FHA definitions, load transformation, and gain relationships in this chapter are consistent with established manufacturer LLC design guidance. Always use the definitions and modeling convention associated with the selected controller and design method, then verify the resulting design with time-domain simulation and prototype measurements.
- STMicroelectronics AN2450 — LLC Resonant Half-Bridge Converter Design Guideline.
- Texas Instruments SLUP263 — Designing an LLC Resonant Half-Bridge Power Converter.
- Infineon — Resonant LLC Converter: Operation and Design.
- Infineon — 600 W LLC Converter Design Guide.
- Texas Instruments SLUAAL2 — UCC25640x LLC Resonant Controller FAQs and Design Example.
Related SolidMagnetics Resources
Chapter 3 — LLC Operation, ZVS, ZCS, and Operating Regions
Review the operating-region and soft-switching framework that constrains the tank design.
Chapter 5 — Transformer Requirements and Operating Window
Chapter 6 — Turns Ratio and Voltage-Gain Design
Translate the converter gain window into a realizable integer transformer turns ratio.
Chapter 7 — Magnetizing Inductance
Develop Lm in detail as a tradeoff among gain, circulating current, ZVS, and loss.
Chapter 8 — Controlled Leakage and Resonant Inductance
Determine how the Lr target should be split between external inductance and transformer leakage.
Ultimate Guide to Resonant Converter Transformer Design
RESONANT CONVERTER TRANSFORMER DESIGN
Ready to Design a Resonant Converter Transformer?
Enter your resonant-converter requirements and begin a SolidMagnetics transformer design workflow built around the electrical, magnetic, winding, thermal, mechanical, and manufacturing constraints that shape a practical LLC or related resonant transformer.
Use the design interface to define the converter operating range, transformer requirements, resonant and magnetizing inductance targets, winding priorities, isolation needs, thermal limits, physical constraints, and optimization goals.
Return to the Ultimate Guide to Resonant Converter Transformer Design
← Previous Chapter
Chapter 3 — LLC Resonant Operation, Soft Switching, and Operating Regions
READY TO APPLY THIS?
Turn Your Requirements Into a Real Magnetic Design
If you are working on a real inductor, flyback transformer, or supported LLC/resonant transformer project, SolidMagnetics can help you move faster from electrical requirements to calculated magnetic geometry and engineering output.
FOUNDING EARLY ENGINEERING ACCESS: $249 → $49
Use coupon code EARLYACCESS for the Single Design package. This offer is intended for engineers who want to evaluate the current SolidMagnetics workflow and provide practical feedback that helps improve the platform.
What the Current Package Can Include
- Requirements and feasibility review
- Candidate design comparison and recommended design
- Electrical, magnetic, loss, and thermal calculations
- SolidWorks Reference CAD and STEP files where supported
- Drawings, BOM, winding, and engineering data where supported
- A basis for comparing custom geometry with commercial core and bobbin options
Early Access Offer Details
- Single Design standard price: $249
- Early Engineering Access price: $49
- Coupon code: EARLYACCESS
- Limited to 10 total qualified paid projects
- One discounted project per customer
- Expires February 12, 2027, or when all 10 uses are claimed
- Brief post-delivery feedback is requested
The standard package provides a Reference CAD representation of the generated design rather than the complete underlying SolidMagnetics parametric automation structure. Fully parametric engineering CAD may be available separately for qualifying advanced or Enterprise projects.
Early Access calculations, CAD, drawings, and related deliverables are intended to accelerate engineering evaluation and prototype development. Final mechanical, electrical, thermal, insulation, regulatory, manufacturing, and production validation remains the responsibility of the customer and their engineering team.