Chapter 8 converts the electrical current envelope from the converter and Chapter 7 magnetizing-current analysis into a physical winding conductor. The conductor must carry RMS and peak current with acceptable DC and AC loss, fit inside the available winding window with insulation, survive temperature and termination stress, and remain manufacturable. The best conductor is therefore not simply the largest copper area that fits.
← Previous Chapter
In This Chapter — Click to Expand
Table of Contents
CHAPTER SCOPE
Select Conductor Technology before Final Winding Arrangement
This chapter determines conductor area and technology—round wire, parallel strands, litz, foil, planar copper, or insulated specialty wire—from current and loss requirements.
Chapter 9 then arranges those conductors physically to control leakage, coupling, AC loss, insulation stress, and manufacturability.
1. Conductor Selection Starts with the Actual Current Waveform
Conductor sizing begins with the actual current waveform in each winding. Primary, secondary, auxiliary, center-tapped, synchronous-rectifier, and resonant windings can have different duty cycles, peaks, RMS values, harmonic content, and current direction. Do not size a transformer winding from output DC current alone.

Figure 8-1. Transformer winding-current decomposition. Conductor sizing uses the actual primary and secondary current waveforms—including magnetizing-current contribution—not only output DC current.
2. RMS Current Sets Copper Heating
RMS current determines resistive heating for a given winding resistance:
3. Average and Peak Current Serve Different Purposes
Average current is:
Average current is useful for charge-flow relationships, while peak current influences stress and current sharing. RMS current is the principal current measure for copper loss.
4. Primary Current Includes Reflected Load and Magnetizing Components
The primary winding current can include reflected load current plus magnetizing current:
5. Current Density Is a Starting Constraint, Not a Universal Constant
A common first-pass conductor metric is current density:
ENGINEERING CAUTION
Do Not Design from One A/mm² Rule
A current-density rule of thumb can generate a first candidate, but final conductor selection must close actual hot copper loss, AC resistance, window fit, and temperature rise.
6. Copper Area Follows from RMS Current and Thermal Target
For a chosen first-pass current-density target:
7. DCR Depends on Copper Length, Area, and Temperature
DC resistance is determined by copper resistivity, conductor length, and copper area:
8. Hot Copper Resistance Must Be Used for Thermal Closure
Copper resistivity increases with temperature:
9. DC Copper Loss Is Only the Beginning at High Frequency
The DC copper-loss estimate is:
At switching frequency, current crowding raises effective resistance, so final winding loss uses AC resistance.
10. Skin Depth Shrinks as Frequency Increases
Skin depth describes the characteristic depth over which AC current penetrates a conductor:
11. Proximity Effect Can Dominate Transformer AC Resistance
Proximity effect is current redistribution caused by magnetic fields from nearby conductors. In transformer windings it can equal or exceed skin effect because adjacent layers carry strong ampere-turn fields.

Figure 8-2. Skin and proximity effects redistribute high-frequency current inside transformer conductors, increasing AC resistance beyond the DC resistance predicted from copper area alone.
12. Use RAC/RDC as a Practical AC-Loss Metric
A useful practical metric is the AC-to-DC resistance factor:
With AC resistance established for the relevant winding-current components, total copper loss can be written as:
13. Harmonic Current Content Matters
Switching waveforms contain harmonics, and each harmonic sees a different AC resistance:
14. Round Wire Is Simple but Not Always Efficient
Round magnet wire is inexpensive, widely available, easy to terminate, and well suited to many low-to-moderate current windings. Its disadvantages appear when a large diameter is required at high frequency or when many layers create strong proximity loss.
15. Parallel Round Conductors Increase Copper Area and Flexibility
Parallel round conductors increase total copper area and allow smaller individual diameters. If current divides approximately equally among np paths:
16. Litz Wire Trades Strand Size and Construction for Lower AC Loss
Litz wire divides the conductor into many individually insulated strands that are transposed so each strand samples different field positions. Total copper area is:
EARLY ENGINEERING ACCESS
Get Your First Custom Magnetic Design for $49
Need a custom inductor, flyback transformer, or currently supported LLC/resonant transformer design for a real project? SolidMagnetics Early Engineering Access gives you a lower-cost way to evaluate the platform while it continues to expand.
STANDARD SINGLE DESIGN PRICE: $249 • EARLY ACCESS PRICE: $49
Use coupon code EARLYACCESS. Your supported design package can include:
- Candidate magnetic design output and recommended design direction
- SolidWorks Reference CAD and STEP export where supported
- Engineering drawings, BOM, winding, and design data where supported
- A practical starting point for component matching, simulation, prototyping, or further development
Offer details: Limited to the first 10 qualified paid projects. One discounted project per customer. Expires February 12, 2027, or when all 10 uses are claimed, whichever comes first.
SolidMagnetics-generated designs are engineering starting points intended to accelerate development. Final component selection, manufacturability, tolerances, winding construction, insulation, creepage and clearance, thermal performance, regulatory requirements, and production suitability must be verified for the intended application.
17. Foil Is Excellent for High Current but Sensitive to Field Orientation
Copper foil provides large cross-sectional area with low radial build and can be attractive for high-current secondaries. Its area is:
18. Planar Copper Enables Repeatable Low-Profile Windings
Planar windings use PCB copper, lead frames, stamped copper, or other flat conductors integrated into a low-profile magnetic structure. Advantages include repeatable geometry and automation; tradeoffs include copper thickness limits, vias, capacitance, and stack complexity.
19. Triple-Insulated Wire Can Trade Copper Space for Safety Simplicity
Triple-insulated wire can simplify reinforced-insulation construction by incorporating a qualified insulation system around the conductor. The tradeoff is reduced effective copper fill, larger outside diameter, and supplier-specific processing requirements.
20. Window Fill Must Include Real Insulation and Manufacturing Space
The copper fill fraction can be expressed as:
The usable winding window must already exclude bobbin walls, creepage margins, tape, barriers, shields, lead channels, and production clearance.
21. Terminations and Leads Are Part of the Conductor Design
Leads, pins, tabs, solder joints, welds, crimps, and PCB terminations can become the highest-resistance or highest-current-density part of the winding. High-current designs need termination geometry sized for RMS current, peak current, heating, and assembly process.
22. Fringing Fields and Leakage Fields Can Create Local Hot Spots
Local magnetic fields can create conductor hot spots that are not predicted by average current density. Center-leg gaps can create fringing loss, poorly arranged layers can create proximity fields, and lead exits can cross high-field regions.
23. Build a Winding-Current Operating-Corner Matrix
Build an operating-corner matrix using RMS current, peak current, switching frequency, harmonic content, copper temperature, conductor resistance, estimated RAC/RDC, and resulting loss.

Figure 8-3. Transformer winding-current operating-corner matrix. Worst-case copper loss can occur at a different operating point than worst-case peak current or magnetic flux.
24. Worked Example — Choosing a Primary Conductor
Consider an illustrative primary winding carrying 4.0 A RMS with a first-pass current-density target of 4 A/mm². The initial bare-copper area target is 1.0 mm². If hot DCR is 30 mΩ, DC-only copper loss is approximately 0.48 W. If AC effects raise RAC/RDC to 1.8, winding loss becomes approximately 0.86 W.
WORKED EXAMPLE
DC Area Is Only the First Candidate
The numerical current-density target and RAC/RDC value are illustrative, not universal design rules.
25. Compare Conductor Technologies as a System Tradeoff
Conductor technologies should be compared as a complete system tradeoff.
| Conductor | Strengths | Important tradeoffs |
|---|---|---|
| Round wire | Low cost, easy sourcing/termination | Skin/proximity loss with large diameter or many layers |
| Parallel round wire | More copper area, smaller individual diameter | Current sharing, bundling, termination complexity |
| Litz wire | Lower high-frequency AC loss when properly designed | Cost, termination, fill factor, supplier-specific construction |
| Copper foil | High current, low radial build | Proximity/eddy loss, insulation, edge/termination design |
| Planar / PCB copper | Repeatable geometry, low profile, automation | Copper thickness, vias, capacitance, PCB stack complexity |
| Triple-insulated wire | Can simplify safety insulation | Larger OD, lower copper fill, processing restrictions |

Figure 8-4. Transformer conductor technologies trade copper area, AC loss, winding-window use, insulation, termination, cost, and manufacturability differently.
26. Recommended Winding-Conductor Workflow
- Start with the complete primary, secondary, and auxiliary current waveforms from the converter model.
- Include magnetizing-current contribution from Chapter 7 in the primary current.
- Calculate RMS, peak, and average current for each winding and operating corner.
- Choose a first-pass current-density target from thermal and packaging goals.
- Calculate required bare copper area.
- Estimate mean turn length and hot DCR.
- Calculate skin depth at the important current harmonics.
- Screen round wire, parallel conductors, litz, foil, planar copper, and insulated specialty wire.
- Estimate AC resistance or RAC/RDC using a geometry-appropriate model, simulation, or measurement.
- Include harmonic current content in AC copper loss.
- Check usable winding-window area after insulation, margins, shields, and manufacturing clearance.
- Check lead, pin, tab, solder, weld, or PCB termination current density and loss.
- Check fringing/proximity hot spots and thermal paths.
- Compare conductor candidates for loss, fit, cost, sourcing, insulation, termination, and automation.
- Carry multiple feasible conductor candidates into Chapter 9 for winding arrangement and leakage/coupling optimization.

Figure 8-5. Winding-conductor selection workflow from current waveforms through copper area, AC loss, window fit, thermal verification, and handoff to winding arrangement.
27. Chapter 8 Engineering Checklist
- Primary, secondary, and auxiliary current waveforms are defined.
- RMS, peak, and average currents are calculated where relevant.
- Primary current includes magnetizing-current contribution.
- First-pass conductor area is based on thermal/current-density goals.
- Mean turn length and hot DCR are estimated.
- Copper temperature dependence is included.
- Skin depth is checked at important frequencies.
- Proximity effect and layer-field exposure are considered.
- RAC/RDC or equivalent AC-loss model is applied.
- Harmonic current content is included where material.
- Round wire, parallel wire, litz, foil, planar, and specialty-insulated options are compared as appropriate.
- Usable winding-window fill includes real insulation and manufacturing space.
- Terminations, pins, tabs, and lead routing are current-rated.
- Fringing and leakage-field hot spots are considered.
- Copper loss is checked at all important operating corners.
- Feasible conductor candidates are ready for Chapter 9 winding arrangement.
28. Conclusion — The Best Conductor Minimizes Total Winding Penalty
The best winding conductor minimizes the total penalty of DC loss, AC loss, window usage, temperature, insulation complexity, termination difficulty, cost, sourcing risk, and manufacturing effort. A conductor with the lowest DCR can still be a poor high-frequency winding if proximity loss or termination geometry dominates.
Chapter 9 now takes the feasible conductor candidates and arranges them physically to control leakage inductance, coupling, field distribution, insulation stress, and manufacturability.
Technical References for This Chapter
Use production conductor datasheets and winding-process data for exact copper dimensions, insulation build, temperature ratings, strand construction, resistance, and termination requirements.
- Transformer and Inductor Design Handbook, Colonel Wm. T. McLyman, 4th Edition, CRC Press.
- Fundamentals of Power Electronics, Robert W. Erickson and Dragan Maksimović, 3rd Edition, Springer.
- Switching Power Supply Design, Abraham I. Pressman, Keith Billings, and Taylor Morey, 3rd Edition, McGraw-Hill.
- P. L. Dowell, classic layered-winding analysis for transformer eddy-current effects.
- Use the selected wire, litz, foil, planar, and insulation supplier datasheets for production conductor dimensions and ratings.
Related SolidMagnetics Resources
Ultimate Guide to Transformer Design
Return to the complete 15-chapter transformer-design roadmap.
Chapter 7 — Magnetizing Inductance and Excitation Current
Review the validated magnetizing-current contribution that must be included in primary winding current.
Chapter 9 — Winding Arrangement, Leakage Inductance, and Coupling
Arrange the selected conductors to control coupling, leakage, field distribution, insulation, and manufacturing.
Magnetic Design Automation
Explore the SolidMagnetics design-tool directory and automated magnetic-design workflows.
SOLIDMAGNETICS DESIGN TOOLS
Explore Magnetic Design Automation
SolidMagnetics is developing workflows that connect transformer current waveforms, copper-area selection, AC-loss analysis, winding geometry, CAD-ready outputs, manufacturing documentation, and measured validation.
← Previous Chapter
READY TO APPLY THIS?
Turn Your Requirements Into a Real Magnetic Design
If you are working on a real inductor, flyback transformer, or supported LLC/resonant transformer project, SolidMagnetics can help you move faster from electrical requirements to calculated magnetic geometry and engineering output.
FOUNDING EARLY ENGINEERING ACCESS: $249 → $49
Use coupon code EARLYACCESS for the Single Design package. This offer is intended for engineers who want to evaluate the current SolidMagnetics workflow and provide practical feedback that helps improve the platform.
What the Current Package Can Include
- Requirements and feasibility review
- Candidate design comparison and recommended design
- Electrical, magnetic, loss, and thermal calculations
- SolidWorks Reference CAD and STEP files where supported
- Drawings, BOM, winding, and engineering data where supported
- A basis for comparing custom geometry with commercial core and bobbin options
Early Access Offer Details
- Single Design standard price: $249
- Early Engineering Access price: $49
- Coupon code: EARLYACCESS
- Limited to 10 total qualified paid projects
- One discounted project per customer
- Expires February 12, 2027, or when all 10 uses are claimed
- Brief post-delivery feedback is requested
The standard package provides a Reference CAD representation of the generated design rather than the complete underlying SolidMagnetics parametric automation structure. Fully parametric engineering CAD may be available separately for qualifying advanced or Enterprise projects.
Early Access calculations, CAD, drawings, and related deliverables are intended to accelerate engineering evaluation and prototype development. Final mechanical, electrical, thermal, insulation, regulatory, manufacturing, and production validation remains the responsibility of the customer and their engineering team.