Chapter 4 produced the resonant-tank targets and gain window. Chapter 5 now converts those converter-level results into a formal transformer requirement set. Before selecting turns, core geometry, material, conductor, or winding arrangement, the engineer should define exactly what the transformer must accomplish electrically, magnetically, thermally, mechanically, dielectrically, and in production.
By the end of this chapter, you should be able to create a traceable transformer requirement brief containing the operating-frequency range, power and current envelope, Lm and Lr targets, leakage allocation, parasitic-capacitance objectives, isolation class, thermal limits, mechanical envelope, winding preferences, manufacturing tolerances, and the operating-corner matrix that later chapters will use to select and verify the physical transformer.
← Previous Chapter
Chapter 4 — Resonant Tank Design: Lr, Lm, Cr, Q, Ln, and Gain
Next Chapter →
In This Chapter — Click to Expand
Table of Contents
DESIGN ASSUMPTION
Requirements Before Geometry
This chapter intentionally stops before selecting the final turns ratio, integer turns, core, material, or winding stack.
The purpose is to define the engineering problem cleanly enough that later chapters can generate and compare transformer candidates without silently changing the converter requirements.
1. Transformer Requirements Must Come from the Converter Operating Window
A resonant transformer must work across the converter’s complete operating envelope, not only at nominal line, nominal load, and series resonance. The requirement set should therefore be derived from all operating points that can materially affect gain, current, flux, loss, ZVS, insulation stress, or temperature.
The transformer specification is the bridge between circuit design and magnetic design. If the specification is incomplete, the magnetic design can be internally correct and still fail when connected to the real converter.
SOLIDMAG ENGINEERING INSIGHT
The Transformer Requirement Set Is a Contract Between the Converter and the Magnetics
Converter design establishes what voltage, current, inductance, frequency, isolation, and thermal behavior are required.
Magnetic design must then realize those requirements with a physical component that can be manufactured repeatedly.
2. Freeze the Converter-Level Inputs Before Designing the Transformer
Before transformer design begins, freeze or explicitly mark as provisional the following converter inputs:
| Input Group | Required Information |
|---|---|
| Topology | LLC, CLLLC, or defined resonant variant; half bridge or full bridge. |
| Input source | Minimum, nominal, maximum bus voltage; ripple and transient limits. |
| Output | Voltage range, current range, continuous power, overload power, transient demand. |
| Control | Minimum/maximum switching frequency, burst strategy, startup, current limit, dead time. |
| Tank | fr, Cr, Lr target, Lm target, Ln, Q/load range, required gain window. |
| Secondary | Rectifier or synchronous-rectifier topology and conduction assumptions. |
| Environment | Ambient range, airflow, enclosure, altitude, contamination category where relevant. |
| Safety | Isolation class, working voltage, transient category, applicable product standard. |
| Mechanical | Maximum length/width/height, PCB footprint, mounting, mass or vibration limits. |
ENGINEERING CAUTION
Mark Provisional Inputs Explicitly
A provisional turns ratio or efficiency estimate may be useful for first-pass calculations, but it should not be allowed to become an undocumented final requirement.
Label provisional values so later chapters know which inputs may still move during iteration.
3. Define Output Power, Input Power, and the Available Loss Budget
For a DC output, output power is:
If target efficiency is η, the corresponding input power is:
The total converter loss budget at that point is:
The transformer can use only part of that loss budget because the semiconductor switches, resonant capacitor, rectifiers, gate drivers, PCB conductors, filters, and auxiliary circuits also dissipate power. A transformer-specific loss allocation can be expressed as:
SOLIDMAG ENGINEERING INSIGHT
Efficiency Must Become a Transformer Loss Budget
A system efficiency target is not directly actionable for the magnetic designer until some of the allowable loss is allocated to the transformer.
The transformer loss budget should be revisited after semiconductor and resonant-component losses are better known.
4. Record the Resonant-Tank Targets from Chapter 4
Chapter 4 should hand the transformer designer a defined Lm target, an Lr target or leakage allocation, and a resonant capacitor value. The transformer must preserve those tank relationships after component tolerance and manufacturing variation are included.
If Lr is fully external, the transformer leakage specification may be an upper bound rather than a target. If Lr is integrated, the transformer leakage becomes a primary controlled parameter. If the architecture is hybrid, the transformer specification must state the allocated leakage contribution and tolerance.
5. Define the Complete Switching-Frequency Window
The switching-frequency requirement should be expressed as an actual range:
The range should include the frequencies used at minimum line, maximum line, full load, light load, no load, startup, overload, burst entry/exit, and any protection mode that still energizes the transformer.
| Frequency Corner | Why It Matters to the Transformer |
|---|---|
| Minimum fs | Can increase volt-seconds, resonant current, boost gain, and flux stress. |
| Nominal / near fr | Often a high-power operating point and a major contributor to core and copper loss. |
| Maximum fs | Increases skin/proximity effect, core-loss sensitivity, gate/EMI interaction, and dielectric-current paths. |
| Burst active pulse frequency | Can maintain full flux excursion even when average output power is small. |

Figure 5-1. Transformer operating-frequency envelope mapped to representative LLC operating points including low-line/full-load, resonance-region nominal operation, high-line reduced-gain operation, light load, and burst mode.
6. Build the Transformer Current Envelope
The transformer current specification should report the actual current quantities needed by later design checks. Peak current and RMS current answer different questions.
| Current Metric | Primary Engineering Use |
|---|---|
| Primary peak current | Peak ampere-turns, saturation/flux margin, switch and lead stress. |
| Primary RMS current | Primary winding copper loss, termination loss, AC resistance, thermal design. |
| Magnetizing current | Core excitation, circulating loss, primary ZVS commutation support. |
| Secondary RMS current | Secondary conductor area, AC winding loss, termination loss, synchronous-rectifier stress. |
| Secondary peak current | Peak conductor/termination stress and rectifier current. |
ENGINEERING CAUTION
Do Not Specify Only Output DC Current
A 10 A DC output does not imply a 10 A transformer secondary RMS current.
Use the actual resonant secondary waveform from simulation or FHA/time-domain analysis when sizing conductors and specifying current.
7. Define the Turns-Ratio Design Inputs Without Choosing Turns Yet
Chapter 5 should capture every quantity Chapter 6 needs to choose turns ratio, but it should not prematurely lock the integer turns.
- Minimum, nominal, and maximum input bus voltage.
- Minimum and maximum output voltage.
- Required minimum and maximum converter gain from Chapter 4.
- Half-bridge or full-bridge excitation.
- Rectifier / synchronous-rectifier topology.
- Expected voltage drops at the relevant current.
- Allowed minimum and maximum switching frequency.
- Isolation requirements that may influence winding arrangement.
- Preferred nominal operating point near or away from fr.
Chapter 6 uses these inputs to select the physical turns ratio and integer turns.
8. Define Magnetizing-Inductance Tolerance as a Converter Requirement
Lm tolerance must be specified from converter behavior rather than from a generic transformer-percentage rule. Minimum Lm tends to increase magnetizing current; maximum Lm can reduce available ZVS-supporting current and alter the gain curve.
| Lm Limit | Converter Concern |
|---|---|
| Lm minimum | Higher magnetizing current, conduction loss, possible altered gain and circulating current. |
| Lm maximum | Lower magnetizing current, potentially less boost capability and weaker light-load ZVS margin. |
| Measurement condition | Frequency, amplitude, winding state, temperature, and fixture can affect measured inductance. |
SOLIDMAG ENGINEERING INSIGHT
Lm Tolerance Is a Control-System Requirement
The acceptable Lm range should be determined by gain, current, ZVS, and loss margins at the converter level.
Only after that range is known should the magnetic designer determine whether the core, turns, gap, and manufacturing process can hold it.
9. Define Resonant-Inductance and Leakage Requirements
The resonant-inductance requirement must explicitly state whether transformer leakage is an unwanted parasitic, a controlled resonant element, or one contributor in a hybrid Lr implementation.
| Architecture | Transformer Requirement |
|---|---|
| External Lr | Specify maximum acceptable leakage and its effect on total resonant inductance. |
| Integrated Lr | Specify target primary-referred leakage inductance, tolerance, and measurement method. |
| Hybrid Lr | Specify target leakage contribution and remaining external Lr allocation. |
Chapter 8 develops the leakage-inductance design and measurement method in detail.
ENGINEERING CAUTION
Leakage Inductance Without a Test Method Is Not a Complete Specification
The measured value changes with which windings are shorted, test frequency, fixture parasitics, and connection method.
The production specification should state the exact measurement configuration.
10. Define the Parasitic-Capacitance and EMI Requirements
Primary-to-secondary capacitance creates common-mode current and can alter high-frequency resonant behavior. If EMI or dv/dt current is critical, define a capacitance target or upper limit instead of merely asking for ‘low capacitance.’
- Maximum acceptable primary-to-secondary capacitance.
- Whether an electrostatic shield is allowed.
- Maximum acceptable shield-to-primary or shield-to-secondary capacitance where relevant.
- Permitted interleaving level.
- Common-mode EMI target or system-level current limit.
- Maximum switch-node dv/dt expected at the transformer.
SOLIDMAG ENGINEERING INSIGHT
Leakage and Capacitance Are Coupled Requirements
Interleaving often lowers leakage but raises primary-secondary capacitance.
A transformer requirement set should therefore specify both where they matter; optimizing only one can make the other unacceptable.
11. Define the Thermal Operating Window
Define the maximum ambient temperature, airflow condition, mounting environment, and allowable winding/core hot-spot temperature. A simple transformer temperature-rise requirement is:
The hot spot must remain below the applicable limit:
| Thermal Requirement | Examples |
|---|---|
| Ambient range | Minimum and maximum enclosure/board ambient. |
| Cooling | Natural convection, forced airflow, conduction to PCB/chassis. |
| Winding hot spot | Maximum allowable copper temperature. |
| Core temperature | Maximum ferrite temperature for loss/saturation/lifetime targets. |
| Temperature rise | Maximum ΔT from ambient under specified test condition. |
| Thermal validation | Thermocouple, resistance method, IR, chamber test, or defined combination. |
Chapter 12 develops transformer loss and thermal design in detail.
12. Define Isolation, Insulation, Creepage, and Clearance Requirements
Isolation requirements should come from the end-product safety context, not from a generic transformer rule. Define the working voltage, required insulation category, test voltage, creepage, clearance, material group, pollution degree, altitude, and any required agency or insulation-system constraints.
The dielectric test voltage must exceed the normal working voltage by the margin required by the applicable standard and insulation system:
- Functional, basic, supplementary, reinforced, or other required insulation class.
- Primary-to-secondary working voltage.
- Transient/impulse requirements.
- Creepage and clearance requirements.
- Altitude derating where applicable.
- Insulation material temperature class.
- Triple-insulated wire allowance or restriction.
- Margin tape, sleeving, bobbin barriers, and shield rules.
- Hi-pot / dielectric withstand test requirement.
ENGINEERING CAUTION
Do Not Derive Safety Spacing from the Converter Schematic Alone
Required creepage and clearance depend on the applicable product standard, working voltage, insulation category, pollution degree, material group, altitude, and construction.
Chapter 13 should be tied to the actual end-product safety standard before the winding stack is released.
EARLY ENGINEERING ACCESS
Get Your First Custom Magnetic Design for $49
Need a custom inductor, flyback transformer, or currently supported LLC/resonant transformer design for a real project? SolidMagnetics Early Engineering Access gives you a lower-cost way to evaluate the platform while it continues to expand.
STANDARD SINGLE DESIGN PRICE: $249 • EARLY ACCESS PRICE: $49
Use coupon code EARLYACCESS. Your supported design package can include:
- Candidate magnetic design output and recommended design direction
- SolidWorks Reference CAD and STEP export where supported
- Engineering drawings, BOM, winding, and design data where supported
- A practical starting point for component matching, simulation, prototyping, or further development
Offer details: Limited to the first 10 qualified paid projects. One discounted project per customer. Expires February 12, 2027, or when all 10 uses are claimed, whichever comes first.
SolidMagnetics-generated designs are engineering starting points intended to accelerate development. Final component selection, manufacturability, tolerances, winding construction, insulation, creepage and clearance, thermal performance, regulatory requirements, and production suitability must be verified for the intended application.
13. Define the Mechanical Envelope and Mounting Constraints
The mechanical envelope constrains which core, bobbin, winding, and termination options are physically possible. Define maximum dimensions before the core search begins.
| Mechanical Requirement | Typical Entry |
|---|---|
| Maximum length / width / height | PCB and enclosure limits. |
| Mounting orientation | Vertical, horizontal, planar, through-hole, surface mount. |
| Footprint / pin locations | Existing PCB or preferred pin grid. |
| Keep-out zones | High-voltage separation, airflow, mechanical obstructions. |
| Mass / vibration | Automotive, aerospace, mobile, or shock environment. |
| CAD deliverable | SolidWorks part/assembly, STEP, drawing, 3D envelope. |

Figure 5-2. Transformer mechanical requirement envelope showing maximum length, width, height, PCB footprint, pin zones, creepage keep-outs, and airflow / neighboring-component constraints.
14. Define Winding Technology and Manufacturability Constraints
Winding requirements should describe acceptable technologies and manufacturing constraints without forcing a geometry before current, insulation, and parasitic tradeoffs are evaluated.
- Round wire, litz, foil, planar, or allowed combinations.
- Maximum number of winding layers or sections.
- Allowed parallel strands.
- Minimum bend radius and termination constraints.
- Required margin tape or molded margin.
- Maximum winding fill / practical manufacturing margin.
- Allowed interleaving or split-winding structures.
- Allowed shield foils or Faraday screens.
- Automation / machine-winding requirements.
A useful geometric fill metric is:
ENGINEERING CAUTION
Do Not Set Kfill to 100%
Real production consumes space through insulation overlap, wire placement tolerance, lead exits, section transitions, sleeving, and winding irregularity.
The allowable fill should reflect the actual winding process rather than an ideal CAD cross section.
15. Define Core and Material Constraints Without Prematurely Selecting a Part
Core and material requirements should begin as constraints and preferences rather than a prematurely selected part number.
| Requirement Type | Examples |
|---|---|
| Core family constraints | E, ETD, EER, PQ, RM, planar, custom geometry. |
| Material frequency range | Ferrite grade compatible with the complete fs and flux range. |
| Temperature behavior | Saturation and loss data at minimum and maximum temperature. |
| Availability | Preferred manufacturers, approved vendors, lifecycle status. |
| Mechanical | Maximum core size and bobbin availability. |
| Gap policy | Ungapped, center-gap, distributed-gap, controlled AL, or allowed gap range. |
| Cost / sourcing | Cost ceiling, regional sourcing, dual-source requirement. |
16. Separate Hard Constraints from Optimization Objectives
Hard constraints determine whether a candidate is feasible. Optimization objectives rank candidates that already pass the hard constraints.
| Hard Constraint | Optimization Objective |
|---|---|
| Required Lm range | Lower circulating current |
| Required Lr/leakage range | Lower parasitic capacitance |
| Isolation / creepage / clearance | Smaller size |
| Maximum temperature | Higher efficiency |
| Maximum mechanical envelope | Lower cost |
| Frequency/material validity | Lower EMI |
| Winding fit / manufacturability | Higher power density |
SOLIDMAG ENGINEERING INSIGHT
Optimization Weights Must Not Redefine Feasibility
A preference for minimum size cannot justify saturation, failed isolation spacing, excessive temperature, or an out-of-tolerance Lm/Lr value.
Optimization should rank feasible candidates, not make an infeasible design acceptable.
17. Build the Operating-Corner Matrix
The transformer should be evaluated over a defined operating-corner set Ω rather than independent maxima that may never occur together:
| Dimension | Representative Corners |
|---|---|
| Input voltage | Minimum, nominal, maximum, transient where applicable. |
| Output load | No load, light load, nominal, full load, overload. |
| Switching frequency | Minimum, resonance region, maximum, burst active frequency. |
| Lm | Minimum, nominal, maximum. |
| Lr / leakage | Minimum, nominal, maximum. |
| Cr | Minimum, nominal, maximum. |
| Temperature | Minimum ambient, nominal, maximum ambient / hot soak. |
| Control mode | Startup, continuous regulation, burst, overload, restart. |
ENGINEERING CAUTION
Do Not Combine Impossible Worst Cases
Maximum input voltage, maximum gain, minimum frequency, and maximum load may not occur simultaneously under the real control law.
Build corners from physically possible controller states so the design remains conservative without becoming meaningless.

Figure 5-3. Resonant transformer operating-corner matrix linking input voltage, load, switching frequency, Lm/Lr/Cr tolerance, ambient temperature, and control mode to current, flux, loss, ZVS, and thermal checks.
18. Translate Nominal Targets into Production Specifications
A nominal target becomes a production specification only after tolerance and measurement method are defined. A general form is:
For a one-sided limit, a useful design-margin metric can be expressed as:
| Parameter | Production Specification Must Include |
|---|---|
| Lm | Min/max, test frequency, amplitude, winding connections, temperature/reference condition. |
| Leakage / Lr contribution | Target/range, shorted winding configuration, test frequency, fixture. |
| Turns ratio | Ratio limit, polarity, test method. |
| DCR | Maximum at specified reference temperature; winding terminals. |
| CPS | Maximum or target range and measurement method if controlled. |
| Dielectric withstand | Voltage, waveform, duration, current limit, test points. |
| Dimensions | Mechanical drawing tolerances and pin/lead requirements. |
Chapter 14 develops the complete manufacturing, testing, tolerance, and validation release process.
19. Worked Example — Transformer Requirement Brief for the Chapter 4 Tank
WORKED DESIGN EXAMPLE
Requirement Brief for the Chapter 4 500 W / 48 V Tank
This example continues the educational tank from Chapter 4: 48 V / approximately 500 W output, provisional n = 4, target fr = 150 kHz, Q = 0.5 at full load, Ln = 5, Lr ≈ 31.7 µH, Cr ≈ 35.5 nF, and Lm ≈ 158.5 µH.
The values below illustrate how a tank calculation becomes a transformer requirement brief. They are not recommended production limits.
Output power is approximately:
If the example system target efficiency is 95%:
The total converter loss budget is therefore approximately:
Only a portion of that 26.3 W can be allocated to the transformer. The transformer loss budget must be coordinated with semiconductor, resonant-capacitor, rectifier, PCB, and auxiliary losses.
Assume for illustration that maximum ambient temperature is 50 °C and the transformer hot-spot target is 100 °C. The available transformer temperature rise is:
| Requirement | Illustrative Entry |
|---|---|
| Output | 48 V, 500 W continuous |
| Topology | Half-bridge LLC |
| Target fr | 150 kHz |
| Allowed fs range | 120–220 kHz provisional |
| Target Lm | 158.5 µH nominal; tolerance to be set from gain/ZVS analysis |
| Target total Lr | 31.7 µH nominal |
| Lr architecture | To be decided: external / integrated / hybrid |
| Cr | 35.5 nF nominal tank target |
| Turns ratio | n = 4 provisional; Chapter 6 to finalize integer turns |
| Max ambient | 50 °C illustrative |
| Transformer hot-spot target | ≤ 100 °C illustrative |
| Isolation | To be defined from end-product safety standard |
| Mechanical envelope | To be supplied by product/PCB constraints |
| Winding technology | Round/litz/foil candidates to be compared later |
ENGINEERING CAUTION
The Requirement Brief Is Not Complete Until Current and Safety Data Are Added
The tank values alone do not define wire size, core size, insulation construction, or creepage.
The final requirement brief must also include actual primary/secondary RMS and peak currents, isolation class, mechanical envelope, and environmental conditions.

Figure 5-4. Example resonant-transformer requirement brief converting the Chapter 4 tank solution into electrical, magnetic, thermal, isolation, mechanical, and manufacturing requirements.
20. Requirements Traceability and Design Handoff
Every major transformer requirement should be traceable back to a converter-level source so later changes can be propagated consistently.
| Transformer Requirement | Trace Back To |
|---|---|
| Turns ratio inputs | Vin/Vout/gain window, bridge, rectifier topology. |
| Lm target/range | Gain curves, magnetizing current, ZVS margin. |
| Lr/leakage target | Tank design and external/integrated Lr allocation. |
| Primary RMS current | Tank/current simulation across operating corners. |
| Secondary RMS current | Rectifier/load waveform and turns ratio. |
| Core loss limit | Transformer loss budget and thermal limit. |
| CPS limit | Common-mode EMI and dv/dt requirement. |
| Isolation spacing | End-product safety standard and working voltage. |
| Mechanical envelope | PCB/enclosure requirement. |
| Production test limits | Worst-case converter performance margin. |
SOLIDMAG ENGINEERING INSIGHT
Traceability Is What Makes Later Automation Trustworthy
If a user changes input voltage, output power, frequency range, or isolation requirement, the design engine should know which transformer requirements must be recalculated.
A requirements graph is more valuable than a disconnected list of final numbers.
21. Recommended Transformer-Requirements Workflow
- Import the Chapter 4 gain/tank solution.
- Freeze topology, bridge, rectifier, input/output ranges, and control limits.
- Calculate output power, input power, and total loss budget.
- Allocate a provisional transformer loss/temperature budget.
- Record target Lm, Lr/leakage allocation, Cr, fr, Ln, and gain/frequency range.
- Generate primary and secondary peak/RMS current envelopes.
- Define turns-ratio design inputs without selecting final integer turns.
- Define Lm and leakage tolerances from converter behavior.
- Define CPS/EMI targets.
- Define isolation and safety requirements.
- Define mechanical envelope and mounting.
- Define allowed winding technologies and manufacturing constraints.
- Define core/material preferences and sourcing constraints.
- Separate hard constraints from optimization objectives.
- Build the physically possible operating-corner matrix.
- Convert nominal electrical targets into measurable production specifications.
- Create a traceability table linking each transformer requirement to its converter source.
- Release the requirement brief to Chapter 6 for turns-ratio design.

Figure 5-5. Transformer-requirements workflow from LLC tank solution through operating window, current envelope, inductance tolerances, isolation, thermal and mechanical constraints, production limits, and traceable handoff to turns-ratio design.
22. Chapter 5 Engineering Checklist
- Topology and bridge configuration are frozen or explicitly provisional.
- Vin/Vout/Pout ranges are defined.
- Target efficiency and transformer loss budget are defined.
- fr and complete fs range are defined.
- Lm nominal/min/max are defined or have a clear tolerance-analysis plan.
- Lr target and external/integrated/hybrid allocation are defined.
- Cr target/tolerance is known from Chapter 4.
- Primary peak and RMS current envelopes are available.
- Secondary peak and RMS current envelopes are available.
- Turns-ratio design inputs are complete.
- CPS / EMI requirement is defined where needed.
- Isolation class, working voltage, creepage, clearance, and test requirements are identified.
- Maximum ambient and transformer hot-spot limits are defined.
- Mechanical envelope, footprint, and mounting are defined.
- Allowed winding technologies and manufacturing constraints are defined.
- Core/material/supplier constraints are defined without prematurely locking a part.
- Hard constraints and optimization objectives are separated.
- Operating corners are physically possible and traceable to the control law.
- Production measurement conditions are defined for critical parameters.
CHAPTER TAKEAWAY
A Complete Requirement Set Prevents Downstream Rework
Turns, core, winding, and insulation decisions become much more reliable when the converter operating window is already captured in a formal requirement brief.
Chapter 6 can now select a turns ratio without having to guess at gain, current, isolation, thermal, or mechanical assumptions.
23. Conclusion — A Good Transformer Design Starts with a Complete Requirement Set
A resonant transformer should not be designed from output power and turns ratio alone. The transformer is required to realize a specific inductance network, carry resonant current across a frequency range, preserve soft-switching behavior, meet an isolation system, fit a mechanical envelope, remain within a loss/temperature budget, and hold those parameters through manufacturing variation.
Chapter 5 therefore turns the converter into a formal magnetic design problem. The result is not yet a transformer—it is a traceable set of constraints that the transformer must satisfy.
With that requirement set established, Chapter 6 can select the transformer turns ratio and integer winding turns while preserving the required gain range and operating-frequency limits.
Technical References for This Chapter
The requirement categories in this chapter reflect standard resonant-converter and magnetics design practice. Production designs should use the selected controller documentation, semiconductor data, magnetic material data, safety standards, and supplier/manufacturing capability.
- STMicroelectronics AN2450 — LLC Resonant Half-Bridge Converter Design Guideline.
- Texas Instruments SLUP263 — Designing an LLC Resonant Half-Bridge Power Converter.
- Infineon — Resonant LLC Converter: Operation and Design.
- Texas Instruments — Magnetics Design Handbook.
Related SolidMagnetics Resources
Chapter 4 — Resonant Tank Design
Review Lr, Lm, Cr, Q, Ln, gain, and the Chapter 4 tank solution.
Chapter 6 — Turns Ratio and Voltage-Gain Design
Continue from the completed requirement brief to a realizable transformer ratio and integer turns.
Chapter 7 — Magnetizing Inductance
Develop the Lm target and tolerance from gain, current, ZVS, and loss.
Chapter 8 — Controlled Leakage / Resonant Inductance
Translate the Lr allocation into transformer leakage or an external/hybrid resonant inductor.
Chapter 13 — Isolation, Insulation, and EMI
Develop the physical insulation system, creepage, clearance, capacitance, and EMI controls.
Ultimate Guide to Resonant Converter Transformer Design
RESONANT CONVERTER TRANSFORMER DESIGN
Ready to Design a Resonant Converter Transformer?
Enter your resonant-converter requirements and begin a SolidMagnetics transformer design workflow built around the electrical, magnetic, winding, thermal, mechanical, and manufacturing constraints that shape a practical LLC or related resonant transformer.
Use the design interface to define the converter operating range, transformer requirements, resonant and magnetizing inductance targets, winding priorities, isolation needs, thermal limits, physical constraints, and optimization goals.
Return to the Ultimate Guide to Resonant Converter Transformer Design
← Previous Chapter
Chapter 4 — Resonant Tank Design: Lr, Lm, Cr, Q, Ln, and Gain
Next Chapter →
READY TO APPLY THIS?
Turn Your Requirements Into a Real Magnetic Design
If you are working on a real inductor, flyback transformer, or supported LLC/resonant transformer project, SolidMagnetics can help you move faster from electrical requirements to calculated magnetic geometry and engineering output.
FOUNDING EARLY ENGINEERING ACCESS: $249 → $49
Use coupon code EARLYACCESS for the Single Design package. This offer is intended for engineers who want to evaluate the current SolidMagnetics workflow and provide practical feedback that helps improve the platform.
What the Current Package Can Include
- Requirements and feasibility review
- Candidate design comparison and recommended design
- Electrical, magnetic, loss, and thermal calculations
- SolidWorks Reference CAD and STEP files where supported
- Drawings, BOM, winding, and engineering data where supported
- A basis for comparing custom geometry with commercial core and bobbin options
Early Access Offer Details
- Single Design standard price: $249
- Early Engineering Access price: $49
- Coupon code: EARLYACCESS
- Limited to 10 total qualified paid projects
- One discounted project per customer
- Expires February 12, 2027, or when all 10 uses are claimed
- Brief post-delivery feedback is requested
The standard package provides a Reference CAD representation of the generated design rather than the complete underlying SolidMagnetics parametric automation structure. Fully parametric engineering CAD may be available separately for qualifying advanced or Enterprise projects.
Early Access calculations, CAD, drawings, and related deliverables are intended to accelerate engineering evaluation and prototype development. Final mechanical, electrical, thermal, insulation, regulatory, manufacturing, and production validation remains the responsibility of the customer and their engineering team.