Chapter 1 established why a resonant transformer must be treated as part of the power-transfer network rather than as an isolated voltage-ratio component. Chapter 2 now compares the major resonant-converter families—SRC, PRC, LCC, LLC, and CLLLC—and shows how the topology selected at the converter level changes the magnetic-component requirements.
By the end of this chapter, you should be able to distinguish the major resonant topologies; identify where resonant inductance and capacitance are placed; understand why LLC is the primary design thread for this guide; recognize when transformer leakage can be integrated into the tank; and understand why CLLLC is especially relevant when bidirectional power flow is required.
← Previous Chapter
Chapter 1 — What Makes a Resonant Converter Transformer Different?
In This Chapter — Click to Expand
Table of Contents
DESIGN ASSUMPTION
Topology-Level First-Pass Model
Unless stated otherwise, the comparisons in this chapter use ideal switches, linear inductors and capacitors, an ideal transformer ratio, and a primary-referred load. Parasitic resistance, semiconductor capacitance, dead time, rectifier drops, magnetic nonlinearity, and control limits are introduced only where they materially affect the topology comparison.
These simplified models explain why different resonant networks create different transformer requirements. Later chapters replace the idealized elements with actual magnetic, winding, thermal, and parasitic behavior.
1. Why Resonant Topology Selection Changes the Transformer
The resonant tank determines how the switching bridge exchanges energy with the load. Because the isolation transformer is electrically coupled to that tank—and because some transformer parameters can become tank elements—the converter topology must be selected before the transformer construction is finalized.
Changing from SRC to LLC, for example, does more than add one inductor to a circuit diagram. In an LLC implementation, the transformer’s magnetizing inductance becomes an intentional resonant parameter, and its leakage inductance may also provide some or all of the required series resonant inductance. In a bidirectional CLLLC converter, resonant elements may exist on both sides of the isolation transformer.
SOLIDMAG ENGINEERING INSIGHT
Topology Selection Is a Magnetic-Design Decision
Topology defines which inductances are intentional, where resonant current flows, how much frequency variation is needed for regulation, and whether the transformer is expected to supply resonant inductance through controlled leakage.
A transformer should therefore not be finalized before the resonant architecture is known.
2. The Resonant-Converter Family at a Glance
| Topology | Primary Resonant Elements | Typical Strength | Transformer Implication |
|---|---|---|---|
| SRC | Series L and C | Simple resonant path and low switching loss near resonance | Transformer can emphasize high coupling; external Lr is common unless leakage is deliberately used. |
| PRC | Resonant L with parallel-load resonant behavior | Useful impedance transformation and gain behavior | Circulating current can remain significant at light load; transformer loading differs from SRC. |
| LCC / series-parallel | Multiple reactive elements combining series and parallel behavior | Additional freedom in gain and impedance shaping | Transformer parasitics interact with a higher-order resonant network and must be modeled deliberately. |
| LLC | Lr, Lm, Cr | Broad useful ZVS region, relatively low circulating current near design point, strong integration opportunity | Lm is an intentional transformer parameter; leakage may contribute to Lr. |
| CLLLC | Primary and secondary resonant L/C networks plus magnetizing behavior | Bidirectional operation with more similar forward/reverse resonant behavior | Transformer ratio, leakage, both-side tanks, current direction, and isolation all interact. |

Figure 2-1. Resonant-converter topology family comparison showing simplified SRC, PRC, LCC, LLC, and CLLLC tank structures around a common isolation transformer.
3. The Basic Resonance Relationships
All resonant topologies rely on the frequency dependence of inductive and capacitive reactance. The ideal inductor reactance magnitude is:
The ideal capacitor reactance magnitude is:
For a simple series Lr–Cr pair, the reactances cancel at the series resonant frequency:
A useful characteristic impedance for the series resonant pair is:
ENGINEERING CAUTION
A Resonant Frequency Does Not Describe the Whole Converter
Two converters can use the same numerical resonant frequency and behave very differently because their load connection, additional reactive elements, transformer ratio, quality factor, switching bridge, and control strategy are different.
Use fr as a reference quantity—not as a complete description of converter behavior.
4. Series Resonant Converter (SRC)
In the series resonant converter, the resonant inductor and capacitor lie in series with the power-transfer path. Around series resonance, the ideal tank impedance becomes small and current can approach a sinusoidal waveform. Regulation is generally achieved by moving switching frequency relative to resonance.
SRC is attractive because the resonant path is simple, but wide input or load regulation can require a substantial frequency excursion. Light-load regulation can become difficult because the converter may need to operate far from the preferred resonant point.
| SRC Design Question | Transformer Consequence |
|---|---|
| Is Lr external or transformer-derived? | An external resonant choke permits a tightly coupled transformer; integrated Lr requires controlled leakage. |
| What frequency range is required? | Core and winding losses must be checked across the actual switching-frequency range. |
| How much resonant current flows? | Transformer copper and termination design must use resonant RMS current, not just output DC current. |
| What isolation ratio is needed? | Turns ratio shifts the reflected load and changes the resonant-tank loading. |

Figure 2-2. Series resonant converter showing bridge excitation, series Lr and Cr, isolation transformer, secondary rectification or synchronous rectification, and load.
5. Parallel Resonant Converter (PRC)
A parallel resonant converter arranges the resonant network so the load participates through a parallel-resonant behavior rather than the simple series path used by SRC. This can provide useful gain behavior, but circulating current can remain substantial even when little real power reaches the load.
That light-load circulating current matters to transformer design because copper loss, core excitation, and switch current do not necessarily fall in proportion to output power. A transformer sized only from output watts can therefore be misleading.
SOLIDMAG ENGINEERING INSIGHT
Output Power and Tank Current Can Decouple at Light Load
In some resonant structures, the tank can continue circulating significant current when little real power reaches the load.
Transformer copper loss and thermal behavior must therefore be based on the actual resonant current waveform, not output power alone.
6. Series-Parallel and LCC Resonant Converters
Series-parallel resonant families add another reactive element so the designer can shape gain and impedance over a wider operating range than a simple second-order tank. One common form is the LCC network, which combines one resonant inductor with two capacitive elements arranged to produce both series and parallel characteristics.
The additional degree of freedom can improve regulation or impedance matching, but it also makes parasitic inductance and capacitance more important. Transformer leakage and interwinding capacitance can shift the behavior of a higher-order network, so they should not be treated as afterthoughts.
ENGINEERING CAUTION
Higher-Order Tanks Increase Modeling Responsibility
Adding reactive elements creates more design freedom, but it also creates more resonant interactions. A simplified tank model can become inaccurate if transformer leakage, device capacitance, or winding capacitance is comparable to an intentional resonant element.
Estimate or measure parasitics early enough that the final hardware still matches the intended network.
7. LLC Resonant Converter
The LLC converter adds the transformer magnetizing inductance Lm to the series resonant Lr–Cr path. That creates a three-reactive-element tank in which the transformer itself contributes one of the fundamental resonant parameters.
The series Lr–Cr resonance remains:
A lower characteristic resonance appears when Lr and Lm participate together:
The normalized inductance ratio is commonly written:
Those relationships are one reason LLC magnetics require a different workflow from a conventional transformer. Lm is not simply maximized; it is selected. Lr is not always a separate component; it may be partly or entirely realized through leakage. Chapter 4 will develop the gain implications quantitatively.

Figure 2-3. LLC resonant converter showing bridge, Cr, Lr, transformer magnetizing branch Lm, ideal turns ratio, secondary rectification, and the option for transformer leakage to contribute to Lr.
8. Why LLC Became the Primary Design Thread for This Guide
This Ultimate Guide covers the broader resonant family, but LLC is the primary design thread because it combines several features that make transformer design especially important: frequency-controlled gain, primary-side ZVS over a useful operating region, secondary soft-switching opportunities, relatively low circulating current near the intended operating point, and strong potential for magnetic integration.
- Magnetizing inductance is an intentional resonant-tank variable.
- Transformer leakage can be designed as useful resonant inductance.
- Turns ratio and resonant gain must be selected together.
- Winding geometry directly changes leakage and capacitance.
- Soft-switching margin depends partly on magnetizing and resonant current.
- Core and conductor loss must be evaluated across a variable switching-frequency range.
- Manufacturing tolerance of Lm and leakage can move the converter gain characteristic.
SOLIDMAG ENGINEERING INSIGHT
LLC Makes Transformer Geometry Part of Converter Tuning
In a tightly integrated LLC implementation, changing the winding structure can change Lr, Lm, coupling, capacitance, AC resistance, and EMI at the same time.
That is exactly the kind of coupled design problem that benefits from a traceable magnetic-design workflow.
9. Half-Bridge vs. Full-Bridge Resonant Excitation
The resonant tank may be driven by a half bridge or a full bridge. The choices change applied tank voltage, device count, current level, and control implementation, while the magnetic design remains tied to the resulting tank voltage and current waveforms.
| Bridge | Typical Advantage | Transformer / Tank Consequence |
|---|---|---|
| Half bridge | Fewer primary switches and common use in medium-power isolated supplies | Tank sees a lower square-wave amplitude than an equivalent full bridge, affecting turns ratio and current for a given bus voltage. |
| Full bridge | Higher available applied tank voltage and often attractive as power rises | Can reduce current for a given transferred power but uses more switches and gate-drive channels. |
| Bidirectional active bridges | Allows controlled power flow in both directions | Used in CLLLC and related structures; transformer and resonant tanks must support both forward and reverse operation. |
At the ideal power level, the familiar relationship remains:
A higher available bridge voltage can reduce required current for a given power level, but the actual resonant RMS current must still be calculated from the tank solution rather than from P/V alone.
10. Transformer Turns Ratio and Reflected Load Still Matter
The transformer turns ratio establishes the basic voltage-scaling relationship and also reflects the secondary-side load into the primary-referred resonant model. Define:
For an ideal impedance referred through the transformer:
The squared relationship is important because changing turns ratio changes more than secondary voltage. It changes the load seen by the resonant tank, which changes quality factor, gain shape, resonant current, and required switching-frequency range.
ENGINEERING CAUTION
Do Not Change Turns Ratio Without Rechecking the Tank
A one-turn change can materially alter the reflected load when the secondary turn count is small.
After integer turns are selected, re-evaluate the resonant gain and current solution using the realized ratio rather than the ideal continuous ratio.
EARLY ENGINEERING ACCESS
Get Your First Custom Magnetic Design for $49
Need a custom inductor, flyback transformer, or currently supported LLC/resonant transformer design for a real project? SolidMagnetics Early Engineering Access gives you a lower-cost way to evaluate the platform while it continues to expand.
STANDARD SINGLE DESIGN PRICE: $249 • EARLY ACCESS PRICE: $49
Use coupon code EARLYACCESS. Your supported design package can include:
- Candidate magnetic design output and recommended design direction
- SolidWorks Reference CAD and STEP export where supported
- Engineering drawings, BOM, winding, and design data where supported
- A practical starting point for component matching, simulation, prototyping, or further development
Offer details: Limited to the first 10 qualified paid projects. One discounted project per customer. Expires February 12, 2027, or when all 10 uses are claimed, whichever comes first.
SolidMagnetics-generated designs are engineering starting points intended to accelerate development. Final component selection, manufacturability, tolerances, winding construction, insulation, creepage and clearance, thermal performance, regulatory requirements, and production suitability must be verified for the intended application.
11. Integrated Magnetics Changes the Topology Decision
Resonant topology and magnetic integration are tightly linked. If the converter uses a separate resonant inductor, the transformer can be designed for strong coupling and low leakage. If transformer leakage provides Lr, the winding structure must intentionally create and control that leakage.
| Magnetic Architecture | What Is Integrated | Primary Benefit | Primary Risk |
|---|---|---|---|
| Separate Lr + transformer | Lr is its own magnetic component; transformer supplies Lm and ratio | Independent tuning and simpler transformer leakage target | Additional component, volume, loss, and cost |
| Integrated-leakage LLC | Transformer supplies Lm and most or all Lr through controlled leakage | Higher integration and potentially higher power density | Lr tolerance becomes a winding-geometry and manufacturing-control problem |
| Hybrid | Transformer leakage supplies part of Lr; external component supplies the remainder | Balances integration with adjustability | Tolerance must be allocated between two magnetic elements |
Chapter 8 develops this architecture decision in detail, including leakage measurement, winding geometry, and tolerance. Continue later to controlled transformer leakage and resonant inductance.
12. CLLLC for Bidirectional Power Flow
A conventional LLC stage is naturally optimized for one primary direction of power flow. Bidirectional systems such as battery chargers, vehicle-to-grid interfaces, energy-storage converters, and some DC microgrids often need comparable resonant behavior in both directions.
CLLLC extends the resonant network by adding resonant elements on the secondary side of the isolation transformer. In a simplified design, primary and secondary resonant frequencies can be written separately:
A symmetric first-pass design commonly seeks comparable resonant behavior on the two sides:
The exact reflected relationships depend on the chosen reference side and turns ratio. What matters at this stage is that both-side resonant elements and the transformer must be designed as one bidirectional network.

Figure 2-4. Bidirectional CLLLC converter showing active bridges on both sides of the isolation transformer and resonant elements distributed on the primary and secondary sides.
SOLIDMAG ENGINEERING INSIGHT
Bidirectionality Changes the Transformer’s Operating Envelope
A transformer that works well when one side is always the source may experience different current distribution, switching frequency, soft-switching margin, and parasitic behavior when power reverses.
Bidirectional validation should therefore include both directions rather than treating reverse power flow as a mirror-image assumption.
13. Symmetric vs. Asymmetric CLLLC
A symmetric CLLLC network uses resonant elements on both sides so the forward and reverse operating models can be made similar. This can simplify gain and soft-switching analysis, but it increases component count and can be especially costly or bulky on the low-voltage, high-current side.
Asymmetric CLLLC variants remove or combine selected resonant elements to reduce component count. That can improve cost, packaging, and conduction loss, but the forward and reverse operating characteristics may become less symmetric and require more deliberate control design.
| CLLLC Approach | Primary Advantage | Transformer / Magnetics Implication |
|---|---|---|
| Symmetric | Similar forward and reverse resonant behavior | Both-side resonant values and transformer ratio can be designed around matched behavior, but component count and magnetic volume increase. |
| Asymmetric | Lower component count and potentially lower loss/cost | Forward and reverse tank behavior may differ more strongly; transformer parasitics become more important to the reduced-order network. |
| Highly integrated | Some resonant inductances realized by transformer leakage | Can reduce separate magnetics, but leakage targets become direction-sensitive manufacturing parameters. |
ENGINEERING CAUTION
Do Not Assume Symmetry from the Circuit Drawing Alone
Even a nominally symmetric CLLLC tank can become electrically asymmetric because of turns ratio, winding resistance, device capacitance, rectifier or bridge resistance, leakage distribution, layout, and measurement reference.
Verify the realized forward and reverse networks using the actual transformer and hardware parasitics.
14. How Topology Changes the Transformer Design Requirements
The topology determines which transformer parameters are design inputs and which are merely parasitics to be bounded.
| Transformer Variable | SRC / PRC / LCC | LLC | CLLLC |
|---|---|---|---|
| Turns ratio | Sets voltage scaling and reflected load | Sets voltage scaling and reflected load; selected with LLC gain range | Sets bidirectional voltage relationship and reflected networks in both directions |
| Magnetizing inductance | Usually secondary to main resonant elements, though still relevant to current and core design | Fundamental resonant-tank variable | Fundamental to both-direction tank behavior |
| Leakage inductance | May be minimized or deliberately used as Lr | Often intentionally designed as some/all of Lr | May be integrated into one or both resonant inductive paths |
| Parasitic capacitance | Can shift higher-order behavior and EMI | Affects EMI, ringing, gain at high frequency, and winding tradeoffs | Can affect forward/reverse gain, especially at high frequency |
| Winding arrangement | Balances coupling, loss, isolation, capacitance | Also sets intentional leakage target | Must manage both-side current, leakage distribution, capacitance, and bidirectional behavior |
| Frequency range | Topology/control dependent | Usually a central regulation variable | Often central in both power-flow directions |
The magnetic specification should therefore state the topology explicitly. A specification containing only input voltage, output voltage, power, and switching frequency does not uniquely define a resonant transformer.
15. Topology Selection by Application
| Application Need | Often-Considered Resonant Direction | Why |
|---|---|---|
| Unidirectional high-efficiency isolated DC-DC | LLC | Strong efficiency, ZVS capability, established controller ecosystem, and magnetic integration potential. |
| Simple narrow-range resonant power transfer | SRC | Straightforward resonant path when gain requirements are compatible. |
| Need for additional gain/impedance shaping | LCC / series-parallel | Additional reactive element provides more freedom in transfer characteristic. |
| Bidirectional battery / energy-storage interface | CLLLC | Resonant networks can be arranged for efficient forward and reverse power transfer. |
| High-power implementation needing more applied tank voltage | Full-bridge LLC or CLLLC variant | Full bridge increases available tank drive and may reduce current for a given power level. |
| Cost/volume-sensitive integrated design | Integrated-leakage LLC or CLLLC variant | Transformer leakage can replace part or all of a separate resonant inductance if tolerance can be controlled. |
These are engineering starting points, not universal rules. Input/output range, regulation, transient response, efficiency, power density, fault behavior, semiconductor technology, controller availability, EMI, safety, and manufacturing capability must all be considered.
16. Common Topology-Selection Mistakes
- Selecting LLC because it is popular without checking the required gain range and frequency window.
- Choosing transformer turns ratio before establishing the tank gain requirements.
- Designing for minimum leakage and later discovering that the converter expected leakage to supply Lr.
- Assuming magnetizing inductance should simply be maximized.
- Using output DC current as a substitute for resonant RMS winding current.
- Ignoring transformer capacitance in a high-frequency or high-dv/dt design.
- Treating half-bridge and full-bridge designs as interchangeable without rechecking applied tank voltage and current.
- Assuming a bidirectional LLC behaves like LLC in reverse without analyzing the reverse transfer characteristic.
- Choosing a symmetric CLLLC schematic but ignoring asymmetric real-world parasitics.
- Finalizing a winding stack before deciding whether the resonant inductance is external, integrated, or hybrid.
ENGINEERING CAUTION
Topology Choice Must Survive the Worst Operating Corners
A topology that looks ideal at nominal voltage and full load may require excessive frequency range, lose soft switching, produce high circulating current, or exceed magnetic limits at another operating corner.
Topology selection should therefore be based on an operating-envelope analysis rather than a single nominal schematic.
17. Recommended Topology-Selection Workflow
A practical resonant-topology selection can be organized into the following sequence:
- Define whether power flow is unidirectional or bidirectional.
- Define input-voltage, output-voltage, output-power, and regulation ranges.
- Determine whether galvanic isolation and a particular transformer ratio are required.
- Establish allowable switching-frequency range and preferred control strategy.
- Compare required gain with SRC, LCC, LLC, or CLLLC capability.
- Estimate tank current and circulating-current behavior at nominal and light-load conditions.
- Decide whether resonant inductance will be external, transformer-integrated, or hybrid.
- Check whether the topology can maintain the required ZVS/ZCS behavior at important operating corners.
- Estimate semiconductor, resonant-component, transformer, and thermal stress.
- Review controller availability, sensing, startup, fault, burst, and transient requirements.
- Select the topology and freeze the resonant architecture before finalizing transformer geometry.
- Carry the chosen topology into Chapter 3 for operating-region and soft-switching analysis.

Figure 2-5. Resonant-topology selection workflow from application requirements through gain, frequency range, soft switching, magnetic integration, bidirectionality, semiconductor stress, and final topology selection.
18. Chapter 2 Engineering Checklist
Before moving into detailed LLC operation, confirm that the topology decision answers these questions:
- Is power flow unidirectional or bidirectional?
- Which resonant family is being analyzed: SRC, PRC, LCC, LLC, CLLLC, or a defined variant?
- Is the primary excitation half bridge, full bridge, or another active bridge?
- Where are Lr and Cr physically implemented?
- Is transformer leakage intended to contribute to resonant inductance?
- Is Lm an explicit resonant-tank design target?
- What turns ratio is assumed when reflecting the load into the tank model?
- What minimum and maximum gain must the converter provide?
- What switching-frequency range is permitted?
- What line/load corners must maintain soft switching?
- What circulating-current behavior is acceptable at light load?
- If bidirectional, have both forward and reverse operating modes been analyzed?
- Are transformer capacitance and leakage large enough to alter the intended model?
- Can the selected topology be manufactured with repeatable magnetic parameters?
CHAPTER TAKEAWAY
Choose the Resonant Architecture Before Designing the Final Transformer
The transformer specification is a consequence of the resonant architecture. Once the converter topology and integration strategy are fixed, Lm, Lr/leakage, turns ratio, current, frequency range, parasitic limits, and winding geometry can be developed coherently.
Chapter 3 now focuses on LLC operation, ZVS, ZCS, gain regions, and the operating boundaries that turn those topology choices into transformer requirements.
19. Conclusion — Choose the Resonant Architecture Before Finalizing the Magnetics
SRC, PRC, LCC, LLC, and CLLLC all use resonance, but they do not impose the same requirements on the isolation transformer. The number and placement of reactive elements determine how strongly magnetizing inductance, leakage inductance, parasitic capacitance, turns ratio, and winding geometry participate in the power-transfer function.
For the remainder of this Ultimate Guide, LLC provides the primary unidirectional design thread because it makes the transformer unusually central to converter behavior. CLLLC will remain the key extension when bidirectional power flow is required.
With the topology family established, the next step is to understand the LLC operating regions themselves: where gain is produced, where the tank looks inductive or capacitive, and where ZVS and ZCS can or cannot be maintained.
Technical References for This Chapter
The topology comparisons in this chapter are consistent with manufacturer application guidance for LLC and bidirectional CLLLC resonant converters. Final product designs should use the selected controller documentation, semiconductor data, magnetic material data, safety requirements, and hardware validation.
- STMicroelectronics AN2450 — LLC Resonant Half-Bridge Converter Design Guideline.
- Infineon — Resonant LLC Converter: Operation and Design.
- Texas Instruments SLLA644 — Bidirectional Resonant Converter Topology Discussion.
- Texas Instruments TIDM-02002 — Bidirectional CLLLC Resonant Dual Active Bridge Reference Design.
- Texas Instruments PMP41042 — 3.6 kW Bidirectional CLLLC Resonant Converter Reference Design.
Related SolidMagnetics Resources
Chapter 1 — Resonant Converter Transformer Fundamentals
Chapter 3 — LLC Resonant Operation, Soft Switching, and Operating Regions
Chapter 4 — Resonant Tank Design: Lr, Lm, Cr, Q, Ln, and Gain
Ultimate Guide to Resonant Converter Transformer Design
Return to the complete 15-chapter Resonant Converter Transformer Ultimate Guide.
Resonant Converter Transformer Designer
Open the SolidMagnetics resonant-transformer design request interface.
RESONANT CONVERTER TRANSFORMER DESIGN
Ready to Design a Resonant Converter Transformer?
Enter your resonant-converter requirements and begin a SolidMagnetics transformer design workflow built around the electrical, magnetic, winding, thermal, mechanical, and manufacturing constraints that shape a practical LLC or related resonant transformer.
Use the design interface to define the converter operating range, transformer requirements, resonant and magnetizing inductance targets, winding priorities, isolation needs, thermal limits, physical constraints, and optimization goals.
Return to the Ultimate Guide to Resonant Converter Transformer Design
← Previous Chapter
Chapter 1 — What Makes a Resonant Converter Transformer Different?
READY TO APPLY THIS?
Turn Your Requirements Into a Real Magnetic Design
If you are working on a real inductor, flyback transformer, or supported LLC/resonant transformer project, SolidMagnetics can help you move faster from electrical requirements to calculated magnetic geometry and engineering output.
FOUNDING EARLY ENGINEERING ACCESS: $249 → $49
Use coupon code EARLYACCESS for the Single Design package. This offer is intended for engineers who want to evaluate the current SolidMagnetics workflow and provide practical feedback that helps improve the platform.
What the Current Package Can Include
- Requirements and feasibility review
- Candidate design comparison and recommended design
- Electrical, magnetic, loss, and thermal calculations
- SolidWorks Reference CAD and STEP files where supported
- Drawings, BOM, winding, and engineering data where supported
- A basis for comparing custom geometry with commercial core and bobbin options
Early Access Offer Details
- Single Design standard price: $249
- Early Engineering Access price: $49
- Coupon code: EARLYACCESS
- Limited to 10 total qualified paid projects
- One discounted project per customer
- Expires February 12, 2027, or when all 10 uses are claimed
- Brief post-delivery feedback is requested
The standard package provides a Reference CAD representation of the generated design rather than the complete underlying SolidMagnetics parametric automation structure. Fully parametric engineering CAD may be available separately for qualifying advanced or Enterprise projects.
Early Access calculations, CAD, drawings, and related deliverables are intended to accelerate engineering evaluation and prototype development. Final mechanical, electrical, thermal, insulation, regulatory, manufacturing, and production validation remains the responsibility of the customer and their engineering team.